• Title/Summary/Keyword: Full-scale measurement

Search Result 203, Processing Time 0.027 seconds

Simultaneous imaging and radiometric performance simulation for computer generated GOCI optical system with measured characteristics

  • Jeong, Soo-Min;Jeong, Yu-Kyeong;Ryu, Dong-Ok;Yoo, Jin-Hee;Kim, Seong-Hui;Cho, Seong-Ick;Ham, Sun-Jeong;Youn, Heong-Sik;Woo, Sun-Hee;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.3-28
    • /
    • 2008
  • In this study, we report a new Monte Carlo ray tracing technique for estimating GOCI (Geostationary Ocean Color Instrument) radiative transfer characteristics and imaging performance simultaneously. First, a full scale GOCI optical model was constructed with measured characteristics at the component level and placed in the geostationary orbit. An optical model of approximated GOCI target area centered at the Korean penninsular was then built using the USGS coastal line data and representative land and sea surface reflectivity data. The light rays launched from a simulated sun model travel to the Earth surface, where they are reflected and scattered. Some of the light rays that are headed to the GOCI model in the orbit were selected and traced, as they have entered into the GOCI aperture. As they pass through each GOCI optical part, the ray path and intensity are adjusted according to the measured characteristics for reflection, transmission, refractive index and surface scattering. The ray-traced imaging and radiative transfer performance indicators confirm that the computer generated GOCI optical system with measured characteristics can be used for in-orbit operation simulation following the designed measurement sequence. The computational technique and its implications as a operation support tool are discussed.

  • PDF

Fabrication of DMMP gas sensor based on $SnO_2$ (산화주석을 기반으로 한 DMMP 가스센서 제작)

  • Choi, Nak-Jin;Ban, Tae-Hyun;Baek, Won-Woo;Lee, Woo-Suk;Kim, Jae-Chang;Huh, Jeung-Soo;Lee, Duk-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.942-945
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas was dimethylmethylphosphonate($C_3H_9O_3P$, DMMP) that is simulant gas of nerve gas. Sensing material was $SnO_2$ added ${\alpha}-Al_2O_3$ with $4{\sim}20wt.%$ and was physically mixed. And then it was deposited by screen printing method on alumina substrate. Sensor device was consisted of sensing electrode with interdigit(IDT) type in front and heater in back side. Total size of device was $7{\times}10{\times}0.6mm^3$. Crystallite size of fabricated $SnO_2$ were characterized by X-ray diffraction(XRD, Rigaku) and morphology of the $SnO_2$ powders was observed by a scanning electron microscope(SEM, Hitachi). Fabricated sensor was measured as flow type and sensor resistance change was monitored real time using LabVIEW program. The best conditions as added $Al_2O_3$ amounts and operating temperature changes were 4wt.% and $300^{\circ}C$ in DMMP 0.5ppm, respectively. The sensitivity was over 75%. Response and recovery times were about 1 and 3 min., respectively. Repetition measurement was very good with ${\pm}3%$ in full scale.

  • PDF

Estimation of Friction Coefficient Using Smart Strand

  • Jeon, Se-Jin;Park, Sung Yong;Kim, Sang-Hyun;Kim, Sung Tae;Park, YoungHwan
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.3
    • /
    • pp.369-379
    • /
    • 2015
  • Friction in a post-tensioning system has a significant effect on the distribution of the prestressing force of tendons in prestressed concrete structures. However, attempts to derive friction coefficients using conventional electrical resistance strain gauges do not usually lead to reliable results, mainly due to the damage of sensors and lead wires during the insertion of strands into the sheath and during tensioning. In order to overcome these drawbacks of the existing measurement system, the Smart Strand was developed in this study to accurately measure the strain and prestressing force along the strand. In the Smart Strand, the core wire of a 7-wire strand is replaced with carbon fiber reinforced polymer in which the fiber Bragg grating sensors are embedded. As one of the applications of the Smart Strand, friction coefficients were evaluated using a full-scale test of a 20 m long beam. The test variables were the curvature, diameter, and filling ratio of the sheath. The analysis results showed the average wobble and curvature friction coefficients of 0.0038/m and 0.21/radian, respectively, which correspond to the middle of the range specified in ACI 318-08 in the U.S. and Structural Concrete Design Code in Korea. Also, the accuracy of the coefficients was improved by reducing the effective range specified in these codes by 27-34 %. This study shows the wide range of applicability of the developed Smart Strand system.

A Survey on the status of using trichloroethylene(TCE) in Korea (트리클로로에틸렌의 유통·사용 실태조사 결과)

  • Cho, Hyung-Yoel;Cho, Sung-Hyun;Ryoo, Jang-Jin;Kim, Byung Gyu;Park, Seung-Hyun;Kang, Seong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.254-260
    • /
    • 2007
  • Trichloroethylene(TCE) is widely used as a degreasing solvent in workplaces. TCE is primarily toxic to the nervous system, however, systemic disorder like Stevens-Johnson syndrome has been recently reported in small-scale factories, where the government has had limited information of chemical use. A survey was performed to investigate the actual condition of using TCE and to provide practical information to occupational health service agencies and professionals. This survey was carried out on 103 factories out of 430 factories which were conducted periodic work environment measurement for TCE. Degreasing was the most popular reason for using TCE in Korea, which reached to 94%. TCE was also used as a solvent for rubber in the coating or molding process, and adhesives in the bonding process. Metal fabrication was the most common as 23%, followed by assembling automobile parts (17%), and machinery (12%). Workers exposed to TCE during full-shift were 52% while 48% were exposed during short period of the shift or intermittently. Manual or semi-automatic work occupied 87% while automatic work was just 13%. Though automatic work by a closed system was generally lower exposed to TCE, compared to manual work, it can cause a high exposure when the maintenance system is improper. Semi-automatic work especially like open-top degreasing process can cause a high exposure when local exhaust system with condensing and refrigerating coils in the degreaser does not work well. In conclusion, the survey showed nationwide status of TCE exposure in various aspects. It can be used to monitor workplaces and workers exposed to TCE to prevent occupational diseases.

Effects for reduction of roll motion by the control of steering gear (조타장치 제어에 의한 횡동요 감소 효과)

  • Choi, Chan-Moon;Lee, Chang-Heon;Ahn, Jang-Young;Yoshimura, Yasuo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.1
    • /
    • pp.37-45
    • /
    • 2011
  • Reduction of ship's rolling is the most important performance requirement for improving the safety of the crew on board and preventing damage to cargo as well as improving the comfort of the ride. It is a common experience for mariners, to see that steering with a rudder generally induces rolling of the ship, though the original aim of the rudder is to keep the ship's heading to the required course. At the first stage, when a rudder is steered, usually a ship heels in an inward direction, due to the roll moment acting on the rudder. At the next stage in steering, the main heel may change to an outward. This coupling between rudder and roll motion has become an attractive problem from the point of view of roll stabilization using the rudder, because it is a natural in sight that if the rudder action is skillfully related to the change of roll as well as to the course deviation, the roll can be reduced to a certain degree. The main aim of this paper is to discuss the results of the actual full-scale sea trials carried out on steer gear No.1 and No.1 2, the individual quartermaster and to make clear their statistical properties, using the actual data which included measurement of roll angle, roll rate and the comparative tests were carried out immediately after each other, in order to minimize any statistical variation in sea conditions. It can be concluded that the steer gear No. 1 2 reduced the roll motion on average by about 21% in comparison with the No.1 and confirmed the some difference as per a ability of quarter-master's maneuver.

Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly (5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

The Effect of Periocular Acupressure with a Medical Massager for Myopia Children

  • Cha, Ho-Yeol;Jung, A-Ram;Kang, Byoung-kab;Song, Ji-Hoon;Jung, Jae Ho;Cheon, Jin Hong;Choi, Jun Yong;Kim, Kibong
    • The Journal of Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.53-61
    • /
    • 2016
  • Objectives: Considering high prevalence of myopia in Asian countries, social cost paid for myopia may gradually increase in Korea. However, studies for developing myopia treatment are deficient. The study was to evaluate whether the periocular acupressure with a medical massager is effective for suppressing myopia progression. Methods: This study was an investigator-sponsored, prospective, open-labeled, and superiority pre and post single-armed study. 14 myopia children aged 7-12 years wore a medical massager for 15 minutes to stimulate periocular acupoints. For 24 weeks, the participants used the device twice a day. Based on prior studies, the refraction change of naturally proceeded myopia was set as -0.38 D. The axial length change of naturally proceeded myopia was set as 0.228 mm. To assess the safety, we performed vital sign check, physical examination, visual acuity test, slit lamp examination, IOP measurement, and fundus examination. Results: The refraction and axial length of the participants increased. For 24 weeks, the change in refraction was -0.38 D at the right eye and -0.40 D at the left. The change in axial length was 0.21 mm at the right and 0.22 mm at the left. In the safety assessment, any adverse event did not occur. Conclusions: There was no significant difference between the control group and the intervention group. The effect of growth may have more contributed to our result than that of acupressure. Based on our result, a full-scale study will not be conducted.

Fabrication of $SnO_2$ Gas Sensor added by Metal Oxide for DMMP (DMMP 검출용 금속산화물을 첨가한 $SnO_2$ 가스센서 제조)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.54-61
    • /
    • 2003
  • $SnO_2$ gas sensor for the detection DMMP, simulant of nerve gas was fabricated and its characteristics were examined. Sensing materials were $SnO_2$ added by TEX>$\alpha$-$Al_{2}O_{3}$ with 0∼20wt.% and $In_{2}O_{3}$ with 0∼3wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Its dimension was 7$\times$10$\times$0.6$\textrm{mm}^2$. Crystallite size 8t phase identification, specific surface area and morphology of fabricated $SnO_2$ powders were analyzed by X-ray diffraction(XRD), surface area analyzer(BET) and by a scanning electron microscope(SEM), respectively. Sensor was measured as flow type and sensor resistance change was monitored as real time using LabVIEW program. The best sensitivities were 75% at adding 4wt.% TEX>$\alpha$-$Al_{2}O_{3}$, operating temperature $300^{\circ}C$ and 87% at adding 2wt.% $In_{2}O_{3}$, operating temperature $350^{\circ}C$ to DMMP 0.5ppm. Response and recovery times were about 1 and 3 min., respectively. Repetition measurement was very good with $\pm$3% in full scale. As a result, operating temperature was lower TEX>$\alpha$-$Al_{2}O_{3}$ than $In_{2}O_{3}$, but sensitivity was higher $In_{2}O_{3}$ than $\alpha$-$Al_{2}O_{3}$.

Case Study on Remodeling Outlet Structure within a Sedimentation Basin for Improving Performance (침전지 유출부 구조 Remodeling을 통한 개선사례 연구)

  • Kim, Seong-Su;Park, No-Suk;Moon, Yong-Taik;Lee, Sun-Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.911-918
    • /
    • 2006
  • This study was conducted to evaluate the effect of the launder type on settling performance and hydrodynamic behavior within the two certain full-scale sedimentation basins (each flow rate/one basin; $10,000m^3/d$); one is the transverse typed launder(existing basin) and the other is building the finger type launder in combination with the longitudinal baffle. Comparative experimental investigations have been carried out through residual turbidity and particle concentration measurements in each effluent from two basins with the transverse and the finger type launders, respectively. From the experimental results, we could observe that turbidity removal rate in the finger type launder basin (modified basin) is about 30% higher than that in the transverse type launder basin (existing basin). Also, from the measurement of total particle concentration in each effluent, the removal efficiency was improved about 27% within modified basin compared to the existing basin. In order to explain the comparative experimental results and investigate the hydridynamic behavior within each basin in more detail, we conducted computational fluid dynamics (CFD) simulation and verified simulation results with acoustic Doppler velocimetry (ADV) technique. From the CFD simulation, it was investigated that extreme upward flow occurs underneath of the transverse launder. On the other hand, in the case of modified basin, the upward flow, which occurred in the beneath of launder, was much less than that in the existing basins.

Experimental study on the damping estimation of the 5$\times$5 rod bundle (5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF