• 제목/요약/키워드: Full Specimen

검색결과 311건 처리시간 0.023초

슬래브 상부 몰탈층에 사용된 작은시편의 유효성 검토(중량충격음을 중심으로) (Small-size Specimen's Effectiveness That is Used to Mortar Layer of Slab (Heavy-weight Floor Impact Sound))

  • 정진연
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.184-191
    • /
    • 2009
  • This study examined small-size specimen's effectiveness that is used to evaluate floor impact sound performance. Floor impact sound level of small-size specimen is higher than full-size. This is due to excessive impact power of Bang machine. Impact hammer that has small impact power relatively can solve this problem. But, according to the size of specimen, mode shape and frequency that influence to structural borne sound is changed. Slab mode of full-size specimen was changed to frequency design of resilient materials. But in case of small-size specimen, there is no change of vibration mode by resilient materials change, Vibration mode of small-size specimen is the same. Therefore, it is not proper that use small-size specimen in floor impact sound estimation.

흰 광폭평판 시험을 이용한 원자력 배관의 파괴거동예측 (Prediction of Failure Behavior for Nuclear Piping Using Curved Wide-Plate Test)

  • 허남수;김윤재;최재붕;김영진;임혁순;정대율
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.352-361
    • /
    • 2004
  • One important element of the Leak-Before-Break analysis of nuclear piping is how to determine relevant fracture toughness (or the J-resistance curve) for nonlinear fracture mechanics analysis. The practice to use fracture toughness from a standard C(T) specimen is known to often give conservative estimates of toughness. To improve the accuracy, this paper proposes a new method to determine fracture toughness using a nonstandard testing specimen, curved wide-plate in tension. To show validity of the proposed curved wide-plate test, the J-resistance curve from the full-scale pipe test is compared with that from the curved wide-plate test and that from the C(T) specimen. It is shown that the J-resistance curve form the curved wide-plate tension test is similar to, but that from the C(T) specimen is lower than, the J-resistance curve from the full-scale pipe test. Further validation is performed by investigating crack-tip constraint conditions via detailed 3-D FE analyses, which shows that the crack-tip constraint condition in the curved wide-plate tension specimen is indeed similar to that in the full-scale pipe under bending.

복합긴장방식이 적용된 세그멘탈 U형 거더 동적 거동 특성 연구 (A Study of Dynamic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems)

  • 장현옥;장일영
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.369-378
    • /
    • 2024
  • 연구목적: 본 연구는 복합 긴장 방식이 적용된 세그멘탈 PSC U형 거더와 콘크리트 바닥판 슬래브가 합성된 40m 실대형 실험체를 제작하여 동적 거동 실험을 실시하고 수치해석적기법 결과와 비교 검토함으로써 구조적 안정성을 검증하고자 한다. 연구방법: 손상이 없는 실대형 실험체에 impact hammer 타격으로 동적 거동 실험을 실시하여 고유진동수와 감쇠비를 측정하고 수치해석적기법 및 구조물의 일반적인 감쇠비와 상호 비교 검토하였다. 연구결과: 거더와 슬래브 합성단면으로 구성된 수치해석 모델의 고유진동수는 2.561Hz로 계산되었고 실대형 실험체의 고유진동수는 2.670Hz로 계측되었으며 감쇠비는 0.42~0.68%로 산정되었다. 결론: 실대형 실험체 고유진동수는 수치해석 모델의 고유진동수 대비 약 4.3% 증가된 값으로써 실대형 실험체와 수치해석 모델의 질량이 동일하므로(99.97%) 실대형 실험체 강성은 구조적 안전성을 확보하였음을 도출할 수 있으며 결과적으로 실험체의 동적 거동 안정성을 검증하였다. 계측된 감쇠비 0.42~0.68%는 탄성영역의 PSC구조물 감쇠비 0.5~1.0%와 비교하여 볼 때, 안정적 동적 거동임을 확인하였다.

하드웨어-인-더-루프 기반의 배관 평가 시뮬레이터의 개발 (Development of a Piping Integrity Evaluation Simulator Based on the Hardware-in-the-Loop Simulation)

  • 김영진;허남수;차헌주;최재붕;표창률
    • 대한기계학회논문집A
    • /
    • 제25권7호
    • /
    • pp.1031-1038
    • /
    • 2001
  • In order to verify the analytical methods predicting failure behavior of cracked piping, full-scale pipe tests are crucial in nuclear power plant piping. For this reason, series of international test programs have been conducted. However, full-scale pipe tests require expensive testing equipment and long period of testing time. The objective of this paper is to develop a test system which can economically simulate the full-scale pipe test regarding the integrity evaluation. This system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system was developed for the integrity evaluation of nuclear piping based on the methodology of hardware-in-the-loop (HiL) simulation. Using this simulator, the piping integrity can be evaluated based on the elastic-plastic behavior of full-scale pipe, and the high cost full-scale pipe test may be replaced with this economical system.

Fe-18Cr-14Mn-4Ni-0.9N 고질소 내식강의 고온 석출과 변형률 속도에 따른 변형특성 연구 (Deformation behavior of the Fe-18Cr-14Mn-4Ni-0.9N high nitrogen steel under different strain rate conditions)

  • 남승만;김용석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 2006
  • High nitrogen steels (HNS) exhibit both high strength and ductility during tensile deformation. In the present study the Fe-18Cr-14Mn-4Ni-0.9N high nitrogen steel was heat treated at $1000^{\circ}C$ and $1100^{\circ}C$ to produce $Cr_2N$ precipitates in austenite matrix and full austenite microstructures, respectively. Tensile tests of the heat treated specimens were performed at two different strain rates of 0.05/sec and 0.00005/sec. Each tensile curve of the specimens could be well characterized by the the modified Ludwik equation. Plastic deformation of the steel was adequately represented by the four parameters of the modified Ludwik equation. At 0.05/s strain rate, the specimen with the $Cr_2N$ precipitate exhibited higher strength than the full austenite specimen, while the full austenite specimen showed better mechanical properties at 0.00005/s strain rate. It was found that the $Cr_2N$ precipitates influences deformation behavior of the high nitrogen steel significantly.

  • PDF

T-스티프너 보강 CFT 기둥 - H형강보 실대형 접합부의 거동 (Behavior of CFT Column to H-Beam Full-Scale Connections with External T-Stiffeners)

  • 김영주;강창훈;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제13권6호
    • /
    • pp.715-723
    • /
    • 2001
  • 이 논문은 T-스티프너보강된 GFT기둥-H형강보 실대형 접합부의 거동을 나타낸다. 수직요소와 수평요소로 구성된 6개 실험체의 T-스트프너는 보의 전소성모멘트에 대한 강도비를 주요변수로 하여 제작되었다. 실험을 통하여 얻은 주요 내용은 강도, 강성과 소성회전능력이다. 모든 실험체는 대체로 안정된 이력거동을 나타내었으며, 특히 수평요소는 수직요소보다 강도와 강성에 더욱더 큰 영향을 준다. 보의 소성회전성능에 있어서, 조기에 파단한 TS-2를 제외한 실험체들의 평균 보소성회전각은 2.97% rad.이다.

  • PDF

Application of cohesive zone model to large scale circumferential through-wall and 360° surface cracked pipes under static and dynamic loadings

  • Moon, Ji-Hee;Jang, Youn-Young;Huh, Nam-Su;Shim, Do-Jun;Park, Kyoungsoo
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.974-987
    • /
    • 2021
  • This paper presents ductile fracture simulation of full-scale cracked pipe for nuclear piping materials using the cohesive zone model (CZM). The main objective of this study is to investigate the applicability of CZM to predict ductile fracture of cracked pipes with various crack shapes and under quasi-static/dynamic loadings. The transferability of the traction-separation (T-S) curve from a small-scale specimen to a full-scale pipe is demonstrated by simulating small- and full-scale tests. T-S curves are calibrated by comparing experimental data of compact tension specimens with finite element analysis results. The calibrated T-S curves are utilized to predict the fracture behavior of cracked pipes. Three types of full-scale pipe tests are considered: pipe with circumferential through-wall crack under quasistatic/dynamic loadings, and with 360° internal surface crack under quasi-static loading. Computational results using the calibrated T-S curves show a good agreement with experimental data, demonstrating the transferability of the T-S curves from small-scale specimen.

Visualization of Surface Deformation on an Open-Hole Specimen Based on Grating Shearography

  • Lee, Jung-Ryul;Lee, Seung-Seok;Chung, Won-Seok
    • 비파괴검사학회지
    • /
    • 제27권6호
    • /
    • pp.563-575
    • /
    • 2007
  • This contribution contained the classical work of an open-hole tensile plate to demonstrate the performance of grating shearography and to compare with the results obtained by other full-field measurement techniques, The isotropic plate with an open-hole has often appeared in the previous contributions introducing novel full-field method and system. Grating shearography directly provided six quantitative measurands about the specimen's surface kinematics by using a single measurement set: three in-plane strains, in plane rotation, and two out-of-plane slopes. The quasi-plane wavefront of grating metrology led to high signal-to-noise ratio (SNR) and thus neither fitting nor filtering was applied, and the small shearing distance of $101{\mu}m$ could be used. The small shearing distance provided the outstanding spatial resolution of $80{\mu}m$ and sensitivity appropriate for experimental mechanics. Finally, the grating shearography enabled the visualization of the complex surface deformation around the hole and also detected parasitic flexions of the specimen in the micrometer regime during the tensile test.

소형 샤르피 충격시험편에서의 파괴응력에 관한 연구 (A Study on the Fracture Stress in Miniaturized Charpy Impact Specimens)

  • 남승훈;김엄기;이대열;김시천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.132-137
    • /
    • 2001
  • Miniaturized specimen technology is useful to characterize the mechanical behavior using a minimum volume of material, because it is almost impossible to sample the conventional specimen for the fracture toughness test without damage to equipment. Test material was 1Cr-1Mo-0.25V steel which was widely used for turbine rotor material. Two kinds of miniaturized impact specimens were prepared, i.e., miniaturized specimen with side groove and without side groove. The correlation between ductile brittle transition temperature(DBTT) of full size impact specimen and that of miniaturized impact specimen was made. The characteristics of miniaturized impact specimens technique as well as fracture stress were discussed. Finally, we concluded that the characteristics of fracture stress change on aging time were similar to that of DBTT.

  • PDF

Thermal Strain Measurement of Austin Stainless Steel (SS304) during a Heating-cooling Process

  • Ha, Ngoc San;Le, Vinh Tung;Goo, Nam Seo;Kim, Jae Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.206-214
    • /
    • 2017
  • In this study, measurement of thermophysical properties of materials at high temperatures was performed. This experiment employed a heater device to heat the material to a high temperature. The images of the specimen surface due to thermal load at various temperatures were recorded using charge-coupled device (CCD) cameras. Afterwards, the full-field thermal deformation of the specimen was determined using the digital image correlation (DIC) method. The capability and accuracy of the proposed technique are verified by two experiments: (1) thermal deformation and strain measurement of a stainless steel specimen that was heated to $590^{\circ}C$ and (2) thermal expansion and thermal contraction measurements of specimen in the process of heating and cooling. This research focused on two goals: first, obtaining the temperature dependence of the coefficient of thermal expansion, which can be used as data input for finite element simulation; and second, investigating the capability of the DIC method in measuring full-field thermal deformation and strain. The results of the measured coefficient of thermal expansion were close to the values available in the handbook. The measurement results were in good agreement with finite element method simulation results. The results reveal that DIC is an effective and accurate technique for measuring full-field high-temperature thermal strain in engineering fields such as aerospace engineering.