• 제목/요약/키워드: Full Rate

검색결과 1,774건 처리시간 0.028초

형태분석에 의한 특징 추출과 BP알고리즘을 이용한 정면 얼굴 인식 (Full face recognition using the feature extracted gy shape analyzing and the back-propagation algorithm)

  • 최동선;이주신
    • 전자공학회논문지B
    • /
    • 제33B권10호
    • /
    • pp.63-71
    • /
    • 1996
  • This paper proposes a method which analyzes facial shape and extracts positions of eyes regardless of the tilt and the size of input iamge. With the extracted feature parameters of facial element by the method, full human faces are recognized by a neural network which BP algorithm is applied on. Input image is changed into binary codes, and then labelled. Area, circumference, and circular degree of the labelled binary image are obtained by using chain code and defined as feature parameters of face image. We first extract two eyes from the similarity and distance of feature parameter of each facial element, and then input face image is corrected by standardizing on two extracted eyes. After a mask is genrated line historgram is applied to finding the feature points of facial elements. Distances and angles between the feature points are used as parameters to recognize full face. To show the validity learning algorithm. We confirmed that the proposed algorithm shows 100% recognition rate on both learned and non-learned data for 20 persons.

  • PDF

협력 통신에서 시공간부호의 최대 사용 효율 (A Full Utilization of Space-time Block Code in Cooperative Communications)

  • 루?o틴;공형윤
    • 한국통신학회논문지
    • /
    • 제33권2A호
    • /
    • pp.115-120
    • /
    • 2008
  • 본 논문에서는 신호를 소스에서 목적지로 전송하는 것을 도와주는 중계기에 Hurwitz-Radon space-time 부호를 사용한 협력통신을 제안한다. 전송안테나가 2개인 시스템이 간단하고 고속의 데이터 율을 제공하기 때문에 보다 자세히 설명한다. 해석과 시뮬레이션은 제안한 시스템이 최대 다이버시티 계수 3을 획득하는 것을 증명한다. 또한, ML 수신기를 수식적으로 유도하고 결합 지법이 아주 간단한 것을 볼 수 있다.

Fabrication of 2.5 Gbps Burst-mode Receiver and its Full Compliance to GPON

  • Lee, Mun-Seob;Lee, Byung-Tak;Kim, Jong-Deog;Lee, Dong-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.355-358
    • /
    • 2008
  • In the current GPON market and standard, the line bit rate requirement is changing from 1.25 Gbps to 2.5 Gbps. We fabricate a 2.5 Gbps burst-mode receiver with commercially available blocks and optimize it with an APD bias control. A burst-mode measurement setup is made for the full compliance test with the GPON standard. The device meets the partially defined 2.5 Gbps specs in the current ITU G.984.2 standard, also, supports 1.25 Gbps specs for the coexistence issue in an access network. The full-compliant measurement values can be used as a guideline for fixing "for further study" specs in the current GPON standard at 2.5 Gbps.

완전 드롭형 알폼 시스템 개발 (Development on Full Drop Type Aluminium Form System)

  • 임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.14-15
    • /
    • 2021
  • Even though the Al. form system, which was developed to replace the Euro-form, has been used as the slab lower formwork for almost all concrete structures based on the light weight and high conversion rate, the low-noise Drop method has been developed and used in order to overcome the limitations of the Al. Form system such as noise pollution and safety accidents caused by free fall during the demolding. However, as the low-noise drop method is still insufficient, Safety Full Drop Al. Form method is expected to be in the spotlight in the construction market based on its excellent advantages compared to the developed methods. In addition, we plan to conduct research to further contribute to securing the quality of the overall structure through continuous improvement and supplementation by introducing an automation system to the very construction method.

  • PDF

황기약침이 전층피부손상 마우스의 치유에 미치는 영향 (Effect of Astragali Radix Pharmacocupuncture for Wound Healing of Full-Thickness Skin Wound in Mouse)

  • 홍창호;강경화;윤화정;윤현민;송춘호;김철홍
    • 한방안이비인후피부과학회지
    • /
    • 제31권1호
    • /
    • pp.22-31
    • /
    • 2018
  • Objectives : In this study, we investigated whether Astragali Radix Pharmacocupuncture (ARP) has an effective on the full thickness defect wound healing process of mouse. Methods : A total of 50 mice (ICR mouse, 7 week-old male) were divided into control group and ARP group. A single full thickness skin defect was made on the dorsal side of the each mouse using an 8mm diameter biopsy punch. Control group were treated with 0.2㎖ saline and ARP group were treat with 0.2ml ARP at 8 points around the wound every three days total 4 times during the experimental period. The change in wound size, contraction rate, healing rate, and epithelization rate was measured by digital images taken on days 3, 6, 9, and 13, and evaluated using a digital image analysis program. Tissues were collected for histological analysis, RT-PCR, and Western blot on days 3, 6, 9, and 15. Results : The results are as follows. ARP group accelerated the rate of wound contraction, wound healing and epithelization compared to the control group. ARP group showed the decrease of inflammatory cells in early inflammatory phase compared to the control group. ARP group upregulated PECAM-1 mRNA and protein expression compared to the control group. ARP group inhibited the scar width and area compared to the control group. Conclusions: ARP showed positive effects on wound healing through the inhibition of inflammatory reaction and increase of PECAM-1 expression related to the wound healing process.

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권4호
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

판형 열교환기 Full-scale 해석을 위한 1차원 유동 네트워크 모델 및 ε-NTU 모델의 수치적 연구 (NUMERICAL STUDY FOR THE FULL-SCALE ANALYSIS OF PLATE-TYPE HEAT EXCHANGER USING ONE-DIMENSIONAL FLOW NETWORK MODEL and ε-NTU METHOD)

  • 김민성;민준기;하만영
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.47-56
    • /
    • 2014
  • Since a typical plate heat exchanger is made up of a huge number of unitary cells, it may be impossible to predict the aero-thermal performance of the full scale heat exchanger through three-dimensional numerical simulation due to the enormous amount of computing resources and time required. In the present study, a simple flow-network model using the friction factor correlation and a thermal-network model based on the effectiveness-number of transfer units (${\varepsilon}$-NTU) method has been developed. The complicated flow pattern inside the cross-corrugated heat exchanger has been modeled into flow and thermal networks. Using this model, the heat transfer between neighboring streams can be considered, and the pressure drop and the heat transfer rate of full-scale heat exchanger matrix are calculated. In the calculation, the aero-thermal performance of each unitary cell of the heat exchanger matrix was evaluated using correlations of the Fanning friction factor f and the Nusselt number Nu, which were calculated by unitary-cell CFD model.

270 MHz Full HD H.264/AVC High Profile Encoder with Shared Multibank Memory-Based Fast Motion Estimation

  • Lee, Suk-Ho;Park, Seong-Mo;Park, Jong-Won
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.784-794
    • /
    • 2009
  • We present a full HD (1080p) H.264/AVC High Profile hardware encoder based on fast motion estimation (ME). Most processing cycles are occupied with ME and use external memory access to fetch samples, which degrades the performance of the encoder. A novel approach to fast ME which uses shared multibank memory can solve these problems. The proposed pixel subsampling ME algorithm is suitable for fast motion vector searches for high-quality resolution images. The proposed algorithm achieves an 87.5% reduction of computational complexity compared with the full search algorithm in the JM reference software, while sustaining the video quality without any conspicuous PSNR loss. The usage amount of shared multibank memory between the coarse ME and fine ME blocks is 93.6%, which saves external memory access cycles and speeds up ME. It is feasible to perform the algorithm at a 270 MHz clock speed for 30 frame/s real-time full HD encoding. Its total gate count is 872k, and internal SRAM size is 41.8 kB.

상토의 조성에 따른 느티나무 묘목의 생육특성 (Growth Characteristics of Zelkova serrata Seedlings as Affected by Mixed Nursery Soil)

  • 이의열;윤경규;심윤진;이어진;이경철
    • 현장농수산연구지
    • /
    • 제22권2호
    • /
    • pp.17-22
    • /
    • 2020
  • This study was conducted to find out the optimum composition of nursery soil for raising seedling of Zelkova serrata. The treatments were regulated with the three different soil types : full peat moss(PM 100%), peat moss + perlite + vermiculite(1:1:1), peat moss + perlite + vermiculite(1:2:1). The full peat moss(PM 100%) showed the highest photosynthetic activity such as maximum photosynthesis rate(PN max), water use efficiency(WUE), Fv/Fm, PIabs and SPAD value. And also, full peat moss(PM 100%) showed relatively better growth performances. As a result of surveying the whole experiment, full peat moss(PM 100%) soil increases growth performances and enhances overall quality.

Optimization of an extra vessel electromagnetic pump for Lead-Bismuth eutectic coolant circulation in a non-refueling full-life small reactor

  • Kang, Tae Uk;Kwak, Jae Sik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3919-3927
    • /
    • 2022
  • This study presents an optimal design of the coolant system of a non-refueling full-life small reactor by analyzing the space-integrated geometrical and electromagnetic variables of an extra vessel electromagnetic pump (EVEMP) for the circulation of a lead-bismuth eutectic (LBE) coolant. The EVEMP is an ideal alternative to the thermal-hydraulic system of non-refueling full-life micro reactors as it possesses no internal structures, such as impellors or sealing structures, for the transportation of LBE. Typically, the LBE passes through the annular flow channel of a reactor, is cooled by the heat exchanger, and then circulates back to the EVEMP flow channel. This thermal-hydraulic flow method is similar to natural circulation, which enhances thermal efficiency, while providing a golden time for cooling cores in the event of an emergency. When the forced circulation technology of the EVEMP was applied, the non-refueling full-life micro reactor achieve an output power of 60 MWt, which is higher than that achievable via the natural circulation method (30 MWt). Accordingly, an optimized EVEMP for Micro URANUS with a flow rate of 4196 kg/s and developed pressure of 73 kPa under a working temperature of 250 ℃ was designed.