• 제목/요약/키워드: Full Load

검색결과 1,447건 처리시간 0.034초

궤환형 중간 단자 전파형 자기증폭기의 특성 (Characteristics of the Feedback Type Center-Tapped Full Wave Magnetic Amplifier)

  • 박창엽
    • 전기의세계
    • /
    • 제13권4호
    • /
    • pp.25-29
    • /
    • 1964
  • This paper shows that higher amplification can be achieved by applying load current on the internal feedback winding of the magnetic amplifier under test. Since the magnetic flux of the control winding and internal feedback winding saturate the core more fully, the permeability tends to zero and load current increases to the value more than that of ordinary magnetic amplifier without feedback.

  • PDF

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

정하중 재하 시 실물 강성벽 일체형 철도보강노반의 성능평가 (Performance Evaluation of Full Scale Reinforced Subgrade for Railroad with Rigid Wall Under Static Load)

  • 김대상
    • 한국지반신소재학회논문집
    • /
    • 제14권3호
    • /
    • pp.31-42
    • /
    • 2015
  • 강성벽 일체형 철도보강노반의 열차하중 하에서의 성능을 평가하기 위하여 실물 단선 철도 노반과 동일한 규모인 높이*폭*길이(5m*6m*20m)의 보강노반을 건설하였다. 철도보강노반은 높이의 30~40%의 짧은 보강재와 강성벽체, 보강재 연직배치간격 30와 40cm를 적용한 특징이 있다. 경제성 및 시공성 향상을 위하여 강성벽체와 보강토체와의 일체화 연결방식을 3종류(용접형, 힌지볼트형, 굵은 철사형)로 다르게 설계하였다. 철도 설계하중 50kPa의 19.6배에 해당되는 0.98MPa (최대시험하중 5.88MN) 최대하중에 대하여 2회 정하중 재하시험을 실시하였다. 철도보강노반의 성능은 파괴에 대한 안정성, 지지력과 침하, 벽체 발생 수평변위, 보강재 발생 변형률에 대한 검토로부터 평가하였다. 실물 실대형 시험결과로부터 높이의 35% 수준의 짧은 보강재와 힌지 볼트형 연결방식을 채택한 강성벽체 일체형 철도보강노반에서 40cm의 보강재 연직간격을 적용하여도 열차 설계하중 하에서 좋은 성능을 보이는 것을 확인할 수 있었다.

대구경 PHC말뚝 및 대구경 복합말뚝($\phi$1,000mm) 지지력 산정에 관한 연구 (Bearing capacity of large diameter PHC pile and large diameter composite pile)

  • 신윤섭;박재현;황의성;조성한;정문경;이진영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.351-359
    • /
    • 2010
  • Large PHC piles with a diameter of 1,000mm or larger were recently introduced for the first time in Korea. This paper presents full-scale static and dynamic pile load tests performed on two 1,000mm PHC piles and two composite piles with steel pipe piles of the same diameter in the upper portion, installed by driving and pre-boring. The objectives of the tests include evaluating pile drivability, load-settlement relation, allowable bearing capacity, and the stability of mechanical splicing element for the composite pile(a.k.a. non-welding joint). The performance of the large diameter PHC piles were thought to be satisfactory compared to that of middle sized PHC piles with a long history of successful applications in the domestic and foreign markets.

  • PDF

An analytical analysis of the pullout behaviour of reinforcements of MSE structures

  • Ren, Feifan;Wang, Guan;Ye, Bin
    • Geomechanics and Engineering
    • /
    • 제14권3호
    • /
    • pp.233-240
    • /
    • 2018
  • Pullout tests are usually employed to determine the ultimate bearing capacity of reinforced soil, and the load-displacement curve can be obtained easily. This paper presents an analytical solution for predicting the full-range mechanical behavior of a buried planar reinforcement subjected to pullout based on a bi-linear bond-slip model. The full-range behavior consists of three consecutive stages: elastic stage, elastic-plastic stage and debonding stage. For each stage, closed-form solutions for the load-displacement relationship, the interfacial slip distribution, the interfacial shear stress distribution and the axial stress distribution along the planar reinforcement were derived. The ultimate load and the effective bond length were also obtained. Then the analytical model was calibrated and validated against three pullout experimental tests. The predicted load-displacement curves as well as the internal displacement distribution are in closed agreement with test results. Moreover, a parametric study on the effect of anchorage length, reinforcement axial stiffness, interfacial shear stiffness and interfacial shear strength is also presented, providing insights into the pullout behaviour of planar reinforcements of MSE structures.

원주방향 노치형 감육부를 가진 배관의 손상거동 평가 (Evaluation of Failure Behavior of a Pipe Containing Circumferential Notch-Type Wall Thinning)

  • 김진원;박치용
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1295-1302
    • /
    • 2003
  • In order to evaluate a failure behavior of pipe with notch-type wall thinning, the present study performed full-scale pipe tests using the 102mm, Schedule 80 pipe specimen simulated notch- and circular-type thinning defects. The pipe tests were conducted under the conditions of both monotonic and cyclic bending moment at a constant internal pressure of 10 MPa. From the results. of experiment the failure mode, load carrying capacity, deformation ability, and fatigue life of a notch-type wall thinned pipe were investigated, and they were compared with those of a circular-type wall thinned pipe. The failure mode of notched pipe was similar to that of circular-type thinned pipe under the monotonic bending load. Under the cyclic bending load, however, the mode was clearly distinguished with variation in the shape of wall thinning. The load carrying capacity of a pipe containing notch-type wall thinning was about the same or slightly lower than that of a pipe containing circular-type wall thinning when the thinning area was subjected to tensile stress, whereas it was higher than that of a pipe containing circular-type thinning defect when the thinning area was subjected to compressive stress. On the other hand, the deformation ability and fatigue life of a notch-type wall thinned pipe was lower than those of a circular-type wall thinned pipe.

스트레인게이지를 활용한 발전소 터빈 및 주증기 배관의 열팽창 측정 (Thermal Expansion Measurement of Turbine and Main Steam Piping by Using Strain Gages in Power Plants)

  • 나상수;정재원;봉석근;전동기;김윤석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.886-891
    • /
    • 2000
  • One of the domestic co-generation plants have undergone excessive vibration problems of turbine attributed to external force for years. The root cause of turbine vibration may be shan alignment problem which sometimes is changed by thermal expansion and external farce, even if turbine technicians perfectly performed it. To evaluate the alignment condition from plant start-up to full load, a strain measurement of turbine and main steam piping subjected to thermal loading is monitored by using strain gages. The strain gages are bonded on both bearing housing adjusting bolts and pipe stoppers which. installed in the x-direction of left-side main steam piping near the turbine inlet in order to monitor closely the effect of turbine under thermal deformation of turbine casing and main steam piping during plant full load. Also in situ load of constant support hangers in main steam piping system is measured by strain gages and its results are used to rebalance the hanger rod load. Consequently, the experimental stress analysis by using strain gages turns out to be very useful tool to diagnose the trouble and failures of not only to stationary components but to rotating machinery in power plants.

  • PDF

예측 냉방부하를 이용한 빙축열시스템의 최적 운전계획 (Optimal Scheduling of Ice Storage System with Prediction of Cooling Loads)

  • 이경호;최병윤;주용진;이상렬;한승호
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.982-993
    • /
    • 2000
  • This paper describes an optimal control scheduling of an encapsulated ice storage system with a chiller of nominal chiller 34RT(103,200kcal/hr) and an ice storage tank of 170RT-hrs(514,080 kcal). The optimization technique used in the study is dynamic programing. The objective function is summed cost during a day including charge and discharge periods. Control strategies being used commercially are chiller priority and storage priority control. In chiller priority control, the chiller is allowed to run at full capacity during the day, subject to limitations of the building load, and the ice is only melted when and if the load exceeds the chillers full capacity. In contrast to chiller priority control, the aim in storage priority control is to melt as much as ice as possible during the day time period. The system simulation calculates the operation costs for the three control strategies in the condition of the same cooling load and the same ice storage system. The simulation period is a day, assuming that initially the tank is stored fully and the cooling load is perfectly predicted for the scheduling. Also Final state of the tank is to be charged fully.

  • PDF

윤하중 시험과 유한요소해석을 통한 강상판 교면포장의 거동분석 연구 (An Evaluation of Orthotropic Steel Bridge Deck Pavement Behavior Using Wheel Load Testing and 3D Finite Element Analysis)

  • 김태우;최지영;이현종;백종은;엄병식
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.103-110
    • /
    • 2013
  • PURPOSES: The objective of this study is to analyze and evaluate the behavior of orthotropic steel bridge deck pavement using three-dimensional finite element analysis and full-scale wheel load testing. METHODS: Since the layer thickness and material properties used in the bridge deck pavement are different from its condition, it is very difficult to measure and access the behavior of bridge deck pavement in the field. To solve this problem, the full-scale wheel load testing was conducted on the PSMA/Mastic bridge deck pavement and the deflection of bridge deck and horizontal tensile strain on top of pavement were measured under the loading condition. Three-dimensional finite element analysis was conducted to predict the behavior of bridge deck pavement and the predicted deflection and tensile strain values are compared with measured values from the wheel loading testing. RESULTS: Test results showed that the predicted deflections are 10% lower than measured ones and the error between predicted and measured horizontal tensile strain values is less than 2% in the critical location. CONCLUSIONS: The fact indicates that the proposed the analysis is found to be accurate for estimating the behavior of bridge deck pavements.

실물모형 프리텐션 PSC 거더의 구조성능 시험 (A Structural Performance Test of a Full-scale Pretension PSC Girder)

  • 김태균;이두성;이성철
    • 대한토목학회논문집
    • /
    • 제33권5호
    • /
    • pp.1741-1751
    • /
    • 2013
  • 본 연구에서는 프리텐션 공법으로 제작된 프리스트레스 콘크리트 거더의 정적거동을 조사하는 것이 주요 목적이다. 이동식 제작대를 이용하여 현장에서 제작된 지간 30m의 프리텐션 거더에 대한 재하시험이 수행되었다. 모든 시험결과는 수치해석결과와 비교되었으며, 거더의 중앙부에 대한 변위와 변형률이 측정되었다. 실험결과에서 실물모형 시험체의 초기균열발생 하중은 사용하중 보다 1.75배 증가된 하중에서 발생하였다. 또한 연성설계기준을 만족하여 시험체는 초기균열 발생후에 취성파괴하지 않고 연성 파괴될 것으로 판단되었다. 사용성 검토에서 균열발생시의 처짐값이 도로교설계기준(2010)에서 제시한 활하중 재하시의 허용처짐량을 만족하였다. 유한요소 해석결과와 시험결과는 전체적인 거동이 매우 유사하게 나타났으며, 현장제작 프리텐션 거더의 사용성과 안전성 측면에서는 큰 문제가 없는 것으로 판단된다.