• 제목/요약/키워드: Fuel cells

검색결과 1,456건 처리시간 0.026초

고분자전해질 연료전지 예지 진단 기술 (A Review on Prognostics of Polymer Electrolyte Fuel Cells)

  • 이원용;김민진;오환영;손영준;김승곤
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.339-356
    • /
    • 2018
  • Although fuel cell systems have advantages in terms of electric efficiency and environmental impact compared with conventional power systems, fuel cell systems have not been deployed widely due to their low reliability and high price. In order to guarantee the lifetime of 10 years, which is the commercialization goal of Polymer electrolyte fuel cells (PEFCs), it is necessary to improve durability and reliability through optimized operation and maintenance technologies. Due to the complexity of components and their degradation phenomena, it's not easy to develop and apply the diagnose and prognostic methodologies for PEFCs. The purpose of the paper is to show the current state on PEFC prognostic technology for condition based maintenance. For the prognostic of PEFCs, the model driven method, the data-driven, and the hybrid method can be applied. The methods reviewed in this paper can contribute to the development of technologies to reduce the life cycle cost of fuel cells and increase the reliability through prognostics-based health management system.

전산 유체 모델링을 이용한 평판형 고체산화물 연료전지 작동특성 전산모사 (Performance Simulation of Planar Solid Oxide Fuel Cells Characteristics: Computational Fluid Dynamics)

  • 우효상;정용재
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.69-79
    • /
    • 2004
  • 전산모사를 이용하여 특성을 정확하게 모사하기 위해서는 전지 내부에서 발생하는 다양한 물리적, 화학적 현상을 고려하여야 한다. 이를 위해, 본 연구에서는 다양한 전지 내부 현상에 대한 변수를 고려할 수 있는 전산유체 상용코드인 CFD-ACE+를 이용하여 평판형 고체산화물 연료전지의 작동 특성을 분석하였다. 단위 스택에서 발생하는 물질전달과 열전달 및 전기화학 반응에 의한 전하이동을 복합적으로 고려하여, 작동조건 하에서 각 공정적, 구조적 변수 변화에 따른 전지특성을 예측하였다. 이러한 전산모사 방법을 통하여 확산과 유동에 의한 전지 내 반응물과 생성물의 mass fraction 분포와 단위 스택의 내부 온도분포 그리고 전지 특성을 나타내는 polarization curve에 의한 고체산화물 연료 전지의 분극 특성을 정성, 정량적으로 제시하였다. 본 연구를 통해 평판형 단위 스택 내에서의 다양한 변수 변화에 따른 전지의 작동 특성에 대한 효율적 예측이 가능하였고, 고체산화물 연료전지 작동 시 발생하는 현상에 대한 전산모사 접근법을 체계적으로 제시할 수 있었다.

고체산화물 연료전지의 운전 조건에 따른 니켈 전극 황 피독 현상 (Sulfur Poisoning of Ni Anode as a Function of Operating Conditions in Solid Oxide Fuel Cells)

  • 이호성;이현미;임형태
    • 대한금속재료학회지
    • /
    • 제56권12호
    • /
    • pp.893-899
    • /
    • 2018
  • In the present study, we investigated the sulfur poisoning of the Ni anode in solid oxide fuel cells (SOFCs) as a function of operating conditions. Anode supported cells were fabricated, and sulfur poising tests were conducted as a function of current density, $H_2S$ concentration and humidity in the anode gas. The voltage drop was significant under the higher current density (${\sim}714mA/cm^2$) condition, while it was much reduced under the lower current density (${\sim}389mA/cm^2$) condition, at 100 ppm of $H_2S$. A secondary voltage drop, which occurred only at the high current density, was attributed to Ni oxidation in the anode. Thus, operation at high current density with high $H_2S$ concentration may lead to permanent deterioration in the anode. The effect of water content (10%) on the sulfur poisoning was also investigated through a constant current test (${\sim}500mA/cm^2$) at 10 ppm of $H_2S$. The cell operating with 10% wet anode gas showed a much smaller initial voltage drop, in comparison with a dry anode gas. The present study indicates that operating conditions, such as gas humidity and current density, should be carefully taken into account, especially when fuel cells are operated with $H_2S$ containing fuel.

A Strategy for Homogeneous Current Distribution in Direct Methanol Fuel Cells through Spatial Variation of Catalyst Loading

  • Park, Sang-Min;Kim, Sang-Kyung;Peck, Dong-Hyun;Jung, Doo-Hwan
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.331-337
    • /
    • 2017
  • A simple strategy is proposed herein for attaining uniform current distribution in direct methanol fuel cells by varying the catalyst loading over the electrode. In order to use the same total catalyst amount for a serpentine flow field, three spatial variation types of catalyst loading were selected: enhancing the cathode catalyst loading (i) near the cathode outlet, (ii) near the cathode inlet, and (iii) near the lateral areas. These variations in catalyst loading are shown to improve the homogeneity of the current distribution, particularly at lower currents and lower air-flow rates. Among these three variations, increased loading near the lateral areas was shown to contribute most to achieving a homogenous current distribution. The mechanism underlying each catalyst loading variation method is different; very high catalyst-loading is shown to decrease the homogeneity of the distribution, which may be caused by water management in the thick catalyst layer thereof.

용융탄산염연료전지 및 주변기기의 동적시뮬레이션 (Dynamic Simulation of Molten Carbonate Fuel Cell and Mechanical Balance of Plant)

  • 성태홍;김경천
    • 대한기계학회논문집B
    • /
    • 제38권2호
    • /
    • pp.121-128
    • /
    • 2014
  • 본 연구의 목적은 용융탄산염연료전지와 같은 고온연료전지에 동반하는 기계적 주변기기의 타당성을 검토할 수 있는 동적 시뮬레이션 모델을 개발하는 것이다. 연료전지를 운송수단과 같은 독립적인 동력기관에서 사용하기 위해서는 동반하는 기계적 주변기기를 최적화 및 소형화할 필요가 있다. 본 연구에서는 유입가스의 조성, 압력, 유량 및 스택의 온도에 따른 용융탄산염연료전지 내부의 화학반응의 동적 모델링을 구현하고 정상상태 시뮬레이션을 수행하여 실험결과와 비교 분석하였다. 또 연료전지의 전류밀도 제어에 따른 on/off 시뮬레이션을 수행하여 동적 시뮬레이션 모델의 타당성을 분석하였다.

메탄 내부개질 반응을 통한 고체산화물 연료전지의 탄소침적 억제에 관한 연구 (A Study on the Suppression of Carbon Deposition in Solid Oxide Fuel Cells Through Methane Internal Reforming)

  • 강윤혁;임성광;유영성;박진우;배중면
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.473-481
    • /
    • 2007
  • Compared to other types of fuel cells, SOFC has advantages like a wide output range and the direct use of hydrocarbon fuel without the process of external reforming. Particularly because the direct use of fuel without reforming reaction is closely linked to overall system efficiency, it is a very attractive advantage. We tried the operation with methane. However, although methane has a small number of carbons compared to other hydrocarbon fuels, our experiment found the deposition of carbon on the surface of the SOFC electrode. To overcome the problem, we tried the operation through activating internal reforming. The reason that internal reforming was possible was that SOFC runs at high temperature compared to other fuel cells and its electrode is made of Ni, which functions as a catalyst favorable for steam reforming.

고온형 고분자 전해질막 연료전지(HT-PEMFC) 구동환경에 따른 탄소 담지체 부식 평가 (Effect of operating conditions on carbon corrosion in High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs))

  • 이진희;김한성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • The influence of potential and humidity on the electrochemical carbon corrosion in high temperature polymer electrolyte membrane fuel cells(HT-PEMFCs) is investigated by measuring $CO_2$ emission at different potentials for 30 min using on-line mass spectrometry. These results are compared with low tempterature polymer electrolyte membrane fuel cells(LT-PEMFCs) operated at lower temperature and higher humidity condition. Although the HT-PEMFC is operated at non humidified condition, the emitted $CO_2$ in the condition of HT-PEMFC is more than LT-PEMFC at the same potential in carbon corrosion test. Thus, carbon corrosion shows a stronger positive correlation with the cell temperature. In addition, the presence of a little amount of water activate electrochemical carbon corrosion considerably in HT-PEMFC. With increased carbon corrosion, changes in fuel cell electrochemical characteristics become more noticeable and thereby indicate that such corrosion considerably affects fuel cell durability.

  • PDF

신구조 금속지지체형 고체산화물 연료전지 (Study on metal-supported solid oxide fuel cells)

  • 이창보;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.129-132
    • /
    • 2007
  • Advanced structure of metal-supported solid oxide fuel cells was devised to overcome sealing problem and mechanical instability in ceramic-supported solid oxide fuel cells. STS430 whose dimensions were 26mm diameter, 1mm thickness and 0.4mm channel width was used as metal support. Thin ceramic layer composed of anode(Ni/YSZ) and electrolyte(YSZ) was joined with STS430 metal support by using a cermet adhesive. $La_{0.8}Sr_{0.2}Co_{0.4}Mn_{0.6}O_{3}$ perovskite oxide was used as cathode material. It was noted that oxygen reduction reaction of cathode governed the overall cell performance from oxygen partial pressure dependance.

  • PDF

운전 조건에 따른 PEM 연료전지 모델링 및 성능 분석 (Modeling and parametric studies of PEM fuel cell performance)

  • 노영우;김세훈;정귀성;손익제;한국일;안병기
    • 한국수소및신에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.209-216
    • /
    • 2008
  • In the present study, a mathematical model has been formulated for the performance of polymer electrolyte fuel cells. Modify the concentration polarization equation using concentration coefficient that represents the characteristics of bipolar plate reactant distribution. The model predictions have been compared with experimental results and good agreement has been demonstrated for the cell polarization curves. The effects of operating parameters on the performance of fuel cells have been studied. Increases of operation pressure reduce the effect of temperature on the performance.

Concept, Manufacture and Results of the Microtubular Solid Oxide Fuel Cell

  • Sammes, Nigel;Galloway, Kevin;Yamaguchi, Toshiaki;Serincan, Mustafa
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권1호
    • /
    • pp.1-6
    • /
    • 2011
  • This paper summarized concept, manufacture and results of the micro-tubular solid oxide fuel cells (SOFCs). The cells were fabricated by co-sintering of extruded micro-tubular anode support and electrolyte coating layer, and then additional cathode coating. The cells showed quick voltage rising within 1 minute, and the electrochemical performances were closely related to the balance of fuel utilization and performance loss. And a thermal-fluid simulation model was also reported in combination with the electrochemical evaluation results on the GDC-based micro-tubular SOFCs.