• Title/Summary/Keyword: Fuel Utilization

Search Result 433, Processing Time 0.03 seconds

Performance Predictions of the Planar-type Solid Oxide Fuel Cell with Computational Flow Analysis (II) - Non-isothermal Model - (유동 해석을 이용한 평판형 고체 산화물 연료전지의 성능 특성 분석 (II) - 비등온 모델 -)

  • Hyun, Hee-Chul;Sohn, Jeong L.;Lee, Joon-Sik;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.963-972
    • /
    • 2003
  • Performance characteristics of the planar-type solid oxide fuel cell (SOFC) are investigated by the analysis of flow fields coupled with heat and mass transfer phenomena in anode and cathode channels. For these purposes, performance analysis of the SOFC is conducted based on electrochemical reaction phenomena in electrodes and electrolyte coupled with flow fields in anode and cathode channels. In the present study, the isothermal model adopted in the previous paper prepared by the same authors is extended to the non-isothermal model by solving energy equation additionally with momentum and mass transfer equations using CFD technique. It is found that the difference between isothermal and non-isothermal models come from non-uniform temperature distribution along anode and cathode electrodes by solving energy equation in non-isothermal model. Non-uniform temperature distribution in non-isothermal model contributes to the increase of average temperature of the fuel cell and influences its performance characteristics.

Effects of Polyamidoamine Dendrimers on the Catalytic Layers of a Membrane Electrode Assembly in Fuel Cells

  • Lee Jin Hwa;Won Jongok;Oh In Hwan;Ha Heung Yong;Cho Eun Ae;Kang Yong Soo
    • Macromolecular Research
    • /
    • v.14 no.1
    • /
    • pp.101-106
    • /
    • 2006
  • The transport of reactant gas, electrons and protons at the three phase interfaces in the catalytic layers of membrane electrode assemblies (MEAs) in proton exchange, membrane fuel cells (PEMFCs) must be optimized to provide efficient transport to and from the electrochemical reactions in the solid polymer electrolyte. The aim of reducing proton transport loss in the catalytic layer by increasing the volume of the conducting medium can be achieved by filling the voids in the layer with small-sized electrolytes, such as dendrimers. Generation 1.5 and 3.5 polyamidoamine (PAMAM) dendrimer electrolytes are well-controlled, nanometer-sized materials with many peripheral ionic exchange, -COOH groups and were used for this purpose in this study. The electrochemically active surface area of the deposited catalyst material was also investigated using cyclic voltammetry, and by analyzing the Pt-H oxidation peak. The performances of the fuel cells with added PAMAM dendrimers were found to be comparable to that of a fuel cell using MEA, although the Pt utilization was reduced by the adsorption of the dendrimers to the catalytic layer.

A Study on Operation Characteristics of Planar-type SOFC System Integrated with Fuel Processor (연료개질기를 연계한 고체 산화물 연료전지 시스템의 운전 특성에 관한 연구)

  • Ji Hyun-Jin;Lim Sung-Kwang;Yoo Yung-Sung;Bae Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.731-740
    • /
    • 2006
  • The solid oxide fuel cell (SOFC) is expected to be a candidate for distributed power sources in the next generation, due to its high efficiency and high-temperature waste heat utilization. In this study, the 5-cell SOFC stack was operated with pure hydrogen or reformed gas at anode side and air at cathode side. When stack was operated with diesel and methane ATR reformer, the influence of the $H_2O/C,\;O_2/C$ and GHSV on performance of stacks have been investigated. The result shows that the cell voltage was decreased with the increase of $H_2O/C$ and $O_2/C$ due to the partial pressure of fuel and water, and cell voltage was more sensitive to $O_2/C$ than $H_2O/C$. Next, the dynamic model of SOFC system included with ATR reformer was established and compared with experimental data. Based on dynamic model, the operation strategy to optimize SOFC-Reformer system was suggested and simulated.

Full-bridge Soft-Switching PS-PWM DC-DC Converter for Fuel Cell Generation System (연료전지 시스템을 위한 풀-브리지 소프트 위상 천이 PWM DC-DC 컨버터)

  • Mun, S.P.;Suh, K.Y.;Lee, H.W.;Nakaoko, M.;Shin, H.B.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.371-376
    • /
    • 2005
  • In this paper, a new a new full-bridge soft-switching phase shift PWM DC-DC Converter has been proposed, which is suitable for fuel cell based power generation system. The proposed converter has outstanding advantage over the conventional DC-DC converter with respect to high efficiency, high power density, and hish component utilization. In special. the proposed converter has predominant high boosting output voltage and high efficiency characteristics under the inherently severs low output voltage of the fuel cell through the overall load conditions. Moreover, the developed converter has been experimentally tested with the help of a fuel cell simulator, and can generate the V-I characteristics of proton exchange membrane(PEM) fuel cell, so that the performance of the proposed converter could be effectively examined and the validity of the converter could be verified.

  • PDF

Status of Technology and Policy for the Utilization of Biomass in Japan (일본 바이오매스 활용 정책 및 기술현황)

  • Yoon, Young-Man;Yoo, Ho-Chun;Kim, Chang-Hyun;Choi, Eun-Hee;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.4
    • /
    • pp.459-474
    • /
    • 2012
  • Based on the general policy called "Green Growth", the Korean government planed to establish a biomass town in South Korea in order to recover energy from organic waste and to substitute for fossil fuel at rural region. Technical and financial support for the establishment of biomass town was insufficient so far. There are some policies to support biomass town establishment, however financial support from several Korean ministries seemed not to have been used efficiently. Some policies are planned excessively so that they cannot be realized on time. Therefore, there is a need to analyze the status of biomass utilization technology and policy in Japan from the point of view of an external biomass expert, since biomass utilization technology and policy of Japan take good achievement during the many developed countries. For the analyzing of technology and policy in Japan, literatures concerned biomass management policy and biomass town design were collected by visiting Japan Ministry of Agriculture, Forestry and Fisheries and interview of public officials in charge was carried out. There are several implications for the promotion of Korean policy concerned with biomass utilization and biomass town establishment.

System Development of a 100 kW Molten Carbonate Fuel Cell II (Design of Stack and System) (100 kW급 용융탄산염 연료전지 시스템 개발 II(스택 및 시스템 설계))

  • Lim, Hee-Chun;Ahn, Kyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1322-1324
    • /
    • 2002
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately 170 cells are required to generate 100 kW at a current density of 125 mA/$cm^2$ with 6000 $cm^2$ cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at 125 mA/$cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. Also system efficiency was calculated at various type of system and operation conditions.

  • PDF

Effect of Water Induction on the Performance and Exhaust Emissions in a Diesel Engine (II)

  • Ryu, Kyunghyun;Oh, Youngtaig
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1640-1647
    • /
    • 2004
  • This study was to investigate the effects of water induction through the air intake system on the characteristics of combustion and exhaust emissions in an IDI diesel engine. The fuel injection timing was also controlled to investigate a method for the simultaneous reduction of smoke and NOx when water was injected into the combustion chamber. The formation of NOx was significantly suppressed by decreasing the gas peak temperature during the initial combustion process because the water played a role as a heat sink during evaporating in the combustion chamber, while the smoke was slightly increased with increased water amount. Also, NOx emission was significantly decreased with increase in water amount. A simultaneous reduction in smoke and NOx emissions was obtained when water was injected into the combustion chamber by retarding more 2$^{\circ}C$A of the fuel injection timing than without water injection.

Fuel Cell Stack Cell Monitoring Method (연료전지 셀 전압 모니터링 방법에 관한 연구)

  • Kim, Dong-Rak;Kim, Hyun;Ichinose, Toshihiko
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1031_1032
    • /
    • 2009
  • The voltages of unit cells of a fuel cell stack are one of the most significant factors to detect failure conditions and thereof safely control and operate the fuel cell system. In this paper, we describe two methods to monitor the voltages of the unit cells of a stack in consideration of data accuracy, circuit extensibility to various numbers of cells, and cost. The reported methods are approached by (i) the power isolation of cell voltage monitoring part from the communications part and (ii) the utilization of a commercially available cell monitoring integrated circuit IC of a Li-ion battery.

  • PDF

Effect of air flow channel configuration on performance of direct methanol fuel cells. (공기극 채널 형상이 직접 메탄올 연료전지의 성능에 미치는 영향)

  • Hwang, Yong-Sheen;Choi, Hoon;Cha, Suk-Won;Lee, Dae-Young;Kim, Seo-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.137-140
    • /
    • 2007
  • We consider the optimum air flow channel design for DMFC's in the present study. The effect of pressure drop across the inlet and outlet of a stack on the performance of a DMFC is the optimization of such geometric parameters is crucial to minimize the parasitic power usage by the auxiliary devices such as fuel pumps and blowers. In this paper, we present how the pressure drop control can optimize the driving point of a DMFC stack. Further, we show how the optimal fuel utilization ratio can be achieved, not degrading the performance of DMFC stacks. Overall, we discuss how the flow channel design affects the selection of balance of plant(BOP) components, the design of DMFC systems and the system efficiency.

  • PDF

Characteristics of Flame Stabilization of the LFG Mixing Gas (LFG 혼합 연료의 화염 안정화 특성)

  • Kim, Sun-Ho;Oh, Chang-Bo;Lee, Chang-Eon;Lee, In-Dae
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.165-172
    • /
    • 1999
  • Landfill gas has merely half heating value compared with liquified natural gas but can be greatly utilized as a commercial fuel. The authors have examined emission characteristics as well as measured burning velocity of LFG mixed gas which contains plenty of $CO_{2}$. With the viewpoint of fuel utilization, flame stability could be one of important characteristics of LFG. In this study, the comparison experiments are conducted between $CH_{4}$ and LFG for searching the region of flame stabilization based upon the flame blowout at maximum fuel stream velocity. As a result, it is found that stabilization region of LFG is not improved with that of $CH_{4}$ in non-swirl/or weak swirl jet diffusion flame. However, it is also known that flame stability is hardly affected by inert gas in the strong swirl with considering widened flame stabilization region of LFG rather than LNG.

  • PDF