• Title/Summary/Keyword: Frost ratio

Search Result 87, Processing Time 0.028 seconds

Evaluation of Frost Heave Prediction and Frost Susceptibility in Sample using JGS Test Method (일본 동상성판정기준을 적용한 시료의 동상예측 및 동상성 평가)

  • Kim, Young-Chin;Hong, Seung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.926-931
    • /
    • 2008
  • This paper show two different standardized test methods(Japanese Geotechnical Society; JGS 2003). One test is a "Test Method for Frost Heave Prediction Test, JGS 0171-2003", and the other test is a "Test Method for Frost Susceptibility, JGS 0172-2003". The purpose of this test is to obtain the freezing rate(freezing speed), frost heave ratio(heave to sample height), frost heave rate(heaving speed), and other parameters to be used for frost heave prediction and determine the frost susceptibility by freezing test with water intake. This method shall be used to predict the frost heave in frozen ground and evaluate the frost susceptibility of natural and replacement materials.

  • PDF

Experimental assessment of the effect of frozen fringe thickness on frost heave

  • Jin, Hyun Woo;Lee, Jangguen;Ryu, Byun Hyun;Shin, Yunsup;Jang, Young-Eun
    • Geomechanics and Engineering
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • A frozen fringe plays a key role in frost heave development in soils. Previous studies have focused on the physical and mechanical properties of the frozen fringe, such as overall hydraulic conductivity, water content and pore pressure. It has been proposed that the thickness of the frozen fringe controls frost heave behavior, but this effect has not been thoroughly evaluated. This study used a temperature-controllable cell to investigate the impact of frozen fringe thickness on the characteristics of frost heave. A series of laboratory tests was performed with various temperature boundary conditions and specimen heights, revealing that: (1) the amount and rate of development of frost heave are dependent on the frozen fringe thickness; (2) the thicker the frozen fringe, the thinner the resulting ice lens; and (3) care must be taken when using the frost heave ratio to characterize frost heave and evaluate frost susceptibility because the frost heave ratio is not a normalized factor but a specimen height-dependent factor.

An experimental study for reducing frost susceptibility using granulated used-tire (폐타이어분말 혼합이 동상억제에 미치는 영향에 관한 실험적 연구)

  • Kim, Hak-Sam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.147-154
    • /
    • 2006
  • The authors conducted field experiments of frost heave to evaluate a method for reducing frost susceptibility using granulated used-tire mixture for 3 winters. Qualitative analyses for the evaluation of restraint effect of frost susceptibility by utilizing granulated used-tire soil mixture were conducted with the segregation potential concept and frost heave ratio. By mixing soil with granulated tire, the frost susceptibility was decreased drastically. From the result of the analyses, it was confirmed that granulated tire is an excellent material in controlling the frost susceptibility.

  • PDF

Performance Simulation of a R744 Refrigeration System in a Refrigerator Truck under a Frost Condition (착상조건에서 R744 냉매 적용 탑차용 냉장시스템의 성능해석)

  • Kim, Sang Hun;Myoung, Chi Wook;Cho, Hong Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.499-505
    • /
    • 2013
  • R744 has been appropriated for substitute refrigerant, because of its high stability, and environment-friendly nature as a natural refrigerant. To analyze the cooling performance of a refrigeration system in a refrigerator truck using R744 according to the blocking ratio, an analytical model of the refrigeration system was developed under frost conditions, using EES. The performance of the refrigeration system was predicted with the indoor and outdoor air temperature, outdoor air velocity, and compressor speed. As a result, the system performance decreased, with the increase of frost growth. When the blocking ratio was 40.4% in the basic condition, the refrigeration capacity was decreased by 27.1%, compared to the non-frost condition.

Experimental Study about Reduction of Frost-heaving in Railway roadbed which using wasted tire chips (폐타이어 칩을 활용한 철도노반 동상저감에 대한 실험적 고찰)

  • Lee, Syeung-Youl;Kim, Young-Chul;Kim, Nam-Hong;Kim, Myoung-Soo
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.633-639
    • /
    • 2010
  • Cold area in korea, railway roadbed and gravel ballast was occurred frost-heaving. So during winter, track was rising and during thaw, track was sinking. In order to prevent the damage of frost-heaving, we have applied a few countermeasures which are circumfusion of calcium chloride and replacement of gravel ballast method. This countermeasures effect is feeble, not continuous and not eco-friendly. This study suggested that we use wasted tire-chips in frost-heaving area and considered appropriate new method to maintenance. This method was named "A Method of Wasted Tire-Chips Post". To prove effect of this method, we have tested in laboratory and field. The result of frost-heaving-ratio field test was decreased frost-heaving-ratio about 50% using "A Method of Wasted Tire-Chips Post".

  • PDF

Frost Heave of Frost Susceptible Soil According to Performance of Thermo-syphon (열 사이펀 성능에 따른 동상민감성 지반의 거동 비교)

  • Park, Dong-Su;Shin, Mun-Beom;Seo, Young-Kyo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.27-40
    • /
    • 2021
  • The construction method to prevent the frost heave or thaw settlement is called the ground stabilization method, and the thermo-syphon is one of the typical ground stabilization methods. The thermo-syphon has recently been developed with a simple analysis model and thermal analysis has been carried out, but the frost heave of frost susceptible soil was not considered. This study was conducted using ABAQUS internal user subroutine to develop the numerical analysis model (Coupled thermo-mechanical) that can simultaneously perform thermal analysis for the temperature change of the soil according to the thermo-syphon and structural analysis to predict the frost heave of the soil accordingly. As a result of the numerical analysis, the frost heave of the soil decreased as the performance of the thermo-syphon increased. As for the main results, when the thermo-syphon which has contain 25%, 50%, and 100% of refrigerant filling ratio was applied, the reduction ratio of the frost heave was 5.5%, 14.4%, and 21% respectively.

An Experimental Study on the Effects of Design Factors for the Performance of Fin-Tube Heat Exchanger Under Frosting Conditions (착상시 설계인자에 따른 핀-관 열교환기의 성능변화에 관한 실험적 연구)

  • 이관수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2657-2666
    • /
    • 1995
  • In this study, the effects of design factors of finned-tube heat exchanger, such as fin spacing and fin array on the frost growth and heat exchanger performance are investigated under a frosting condition. The results show that the amount of frost, frost density and blockage ratio of air flow passage increase with decreasing fin spacing. Heat transfer rate increases momentarily at the initial stage of frosting and then decreases. After that heat transfer rate continues to increase again to reach a maximum value and then decreases dramatically. It is shown that the time required for heat transfer rate to reach a maximum value becomes shorter with decreasing fin spacing, and after a maximum value, heat transfer rate decreases very fast. The maximum allowable blockage ratio is introduced to determine the operation limit of a finned-tube heat exchanger operating under frosting condition and is obtained as a function of fin spacing. It is also shown that heat transfer rate of heat exchanger with staggered fin array increases about 17% and the amount of pressure drop of air increases about 1~2 mmH$_{2}$O, compared with those of in-line type heat exchanger under frosting condition.

Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck (이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구)

  • Myung, Chi-Wook;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

The Frost-Susceptibility of Compacted Coal Ash with Proper Mixing Ratio of Fly Ash to Bottom Ash (비회와 저회의 적정 혼합비로 다짐한 석탄회의 동상성)

  • Chun, Byung Sik;Gang, In Sung;Koh, Yong Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.173-178
    • /
    • 1993
  • The most appropriate mixing ratio of fly ash to bottom ash obtained from compaction characteristics and CBR values is varying from 5:5 to 6:4. But these mixed ashes are frost-susceptible materials according to judging by the paticle-size distribution because of a lot of silty-size paticles. In this study, the frost-susceptibility of compacted coal ash with proper mixing ratio is examined experimentally for use of subgrade materials. And, the efforts have been made to find proper cement addition in making these mixed ashes frost-insusceptible. It was revealed that these mixed ashes are frost-susceptible, and 4% of cement content is required to be made frost-insusceptable. It was found that amount of frost heave of these mixed ashes decreases with the unconfined compressive strength, and increases with log k if the permeability coefficient k is as low as the water into the freezing front of these mixed ashes is restricted.

  • PDF

An ExperimentalStudy on the Freeze-Thaw Resistance Properties of High Strength Concrete (고강도 콘크리트의 동결융해 저항 특성에 관한 실험적 연구)

  • 송태경;이남주;김제원;설광욱;정환욱;부척량
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.456-461
    • /
    • 1997
  • The purpose of this experimental study are to produce a durable concrete and to investigate the various factors that can deteriorate the concrete when freezing and thawing activity. Among the various factors that can influence the frost resistance of concrete, this study examined mainly the relationship of the frost resistance with the water-cement ratio, admixture and admixture replacement ratio and propose the available water-cement ratio, admixture and admixture replacement ratio.

  • PDF