• Title/Summary/Keyword: Frost prevention

Search Result 32, Processing Time 0.021 seconds

Investigation of Frost Reduction Effect using Mesh Net (그물망을 이용한 서리 저감 효과 구명)

  • Yu, Seok cheol;Kim, Yu yong;Lim, Seong yoon;Song, Ho sung
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.448-455
    • /
    • 2020
  • This study was carried out to investigate reduction of the frost damage using the mesh net used for the purpose of non-bagged cultivation. A device measuring the weight of frost was developed and installed in both the control and the experimental, and the effect of frost reduction was evaluated with their weights. As a result, weight of frost in the control was reduced from 37% to 59% with mesh net on the day the frost was observed. In addition, the device for automatically observing the amount of frost was developed and the height of the windbreak of the frost measuring device was determined to be 30 cm through wind tunnel experiment. The results of this study are expected to reduce frost damage during the flowering season of fruit trees by installing mesh net and it is expected to be used as basic data for agricultural use of mesh net.

Feasibility Study on the Frost Prevention and Delay by the Method of Alternating the function of Outdoor Coil Rows (실외기 기능 교번을 통한 착상 방지 및 지연에 대한 실증 연구)

  • Jeon, Chang Duk
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • The object of this experimental study is to investigate the effect on frost prevention and delay by the method of alternating the function of outdoor coil rows under the frost conditions ($2^{\circ}C/1^{\circ}C$). The heat pump system with the new method can make frost delay time longer and eliminate frost effectively. It is withstand over 280 minutes without a conventional defrosting method. Maximum COP in case of adopting new method is 13% higher than that in case of reverse cycle defrosting method. Also in case of moving air injection duct faster, the frost delay time is lengthened and its COP is enhanced more.

  • PDF

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreeze Solution

  • Chang Young-Soo;Yun Won-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.66-75
    • /
    • 2006
  • The effect of antifreeze solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreeze solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation while having small thermal resistance across the film. A porous layer coating technique is adopted to improve the wettability of the antifreeze solution on a parallel plate heat exchanger. The antifreeze solution spreads widely on the heat exchanger surface with $100{\mu}m$ thickness by the capillary force resulted from the porous structure. It is observed that the antifreeze solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by the thin liquid film are only $1{\sim}2%$ compared with those for non-liquid film surface.

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution (마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구)

  • Chang Young- Soo;Yun Won -Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

Frost Prevention of Fin-Tube Heat Exchanger by Spreading Antifreezing Solution (부동액 도포에 의한 핀-튜브 열교환기 착상방지)

  • Oh, Sang-Youp;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.477-485
    • /
    • 2006
  • A study on frost prevention of fin-tube heat exchanger is experimently performed by spreading antifreezing solution on heat exchanger surface. It is desirable that the antifreezing solution spreads completely on the surface forming thin liquid film to prevent frost nucleation and crystal growth and to reduce the thermal resistance across the liquid film. A small amount of antifreezing solution falls in drops on heat exchanger surface using two types of supplying devices, and a porous layer coating technique is adopted to enhance the wettedness of antifreezing solution on the surface. It is observed that the antifreezing solution liquid film prevents fin-tube heat exchanger from frosting, and heat transfer performance does not degrade through the frosting tests. The concentration of supplied antifreezing solution can be determined by heat transfer analysis of the first row of heat exchanger to avoid antifreezing solution freezing due to dilution by moisture absorption.

The Study about Reduction of Frost-heaving in Railway Small Structures (철도 소형구조물에서의 동상저감방안 연구)

  • Han, Chang-Young;Lee, Joon-Seok;Cho, Kook-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1129-1135
    • /
    • 2011
  • Recently, In Korea region becoming subtropical climate, freezing index values have been increasing in winter. The climate condition in Korean became polarized. Since freezing index is increased recently, track heaving from frost is often occurred, which is ignored in past couple of years. Methods to prevent frost-heaving are circumfusion of calcium chloride and replacement of gravel ballast in usual. The effects of those methods are minimal, incontinuous, and not eco-friendly. Therefore, maintenances are performed repeatedly every year. This study discussed utilizing the waste-tire-chips and insulators in the small structures(bridge and box etc) for prevention of frost-heaving. In order to prove effect of waste-tire-chips, laboratory and field tests were conducted with CBR and measurement of frost-heaving amount to prove and verify effect of insulators.

  • PDF

Mechanical Behavior of Buried Pipe Line with Frost Prevention Materials (동상방지재료를 활용한 온도에 따른 매설관 거동 특성에 대한 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung;Kim, Young-Seok;Lee, Jang-Keun;Hong, Sung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.546-552
    • /
    • 2010
  • Seasonal frozen ground affects structural behavior in South Korea. Frost and heaving of seasonal frozen ground results in the critical damage of roadway, railroad, and buried pipeline. It has been widely used to substitute frost susceptible soils with granular soils. This paper presents experimental investigation on the effectiveness of soil-shredded tire and soil-expanded polystylene (EPS) mixtures to reduce frost depth and force around a buried pipeline. Experimental data such as measured temperature profile and the deformation of buried pipeline were carefully observed and provide the evidence of the effectiveness of soil mixtures.

  • PDF

Bridge Road Surface Frost Prediction and Monitoring System (교량구간의 결빙 예측 및 감지 시스템)

  • Sin, Geon-Hun;Song, Young-Jun;You, Young-Gap
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.42-48
    • /
    • 2011
  • This paper presents a bridge road surface frost prediction and monitoring system. The node sensing hardware comprises microprocessor, temperature sensors, humidity sensors and Zigbee wireless communication. A software interface is implemented the control center to monitor and acquire the temperature and humidity data of bridge road surface. A bridge road surface frost occurs when the bridge deck temperature drops below the dew point and the freezing point. Measurement data was used for prediction of road surface frost occurrences. The actual alert is performed at least 30 minutes in advance the road surface frost. The road surface frost occurrences data are sent to nearby drivers for traffic accidents prevention purposes.

Investigation of the ASTM International frost heave testing method using a temperature-controllable cell

  • Hyunwoo, Jin;Jangguen, Lee;Byung-Hyun, Ryu
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp. 583-597
    • /
    • 2022
  • Frost heave can cause uneven ground uplift that may damage geo-infrastructure. To assist damage-prevention strategies, standard frost heave testing methods and frost susceptibility criteria have been established and used in various countries. ASTM International standard testing method is potentially the most useful standard, as abundant experimental data have been acquired through its use. ASTM International provides detailed recommendations, but the method is expensive and laborious because of the complex testing procedure requiring a freezing chamber. A simple frost heave testing method using a temperature-controllable cell has been proposed to overcome these difficulties, but it has not yet been established whether a temperature-controllable cell can adequately replace the ASTM International recommended apparatus. This paper reviews the applicability of the ASTM International testing method using the temperature-controllable cell. Freezing tests are compared using various soil mixtures with and without delivering blow to depress the freezing point (as recommended by ASTM International), and it is established that delivering blow does not affect heave rate, which is the key parameter in successful characterization of frost susceptibility. As the freezing temperature decreases, the duration of supercooling of pore water shortens or is eliminated; i.e., thermal shock with a sufficiently low freezing temperature can minimize or possibly eliminate supercooling.

Effects of planting date for the prevention of frost-pillar damage and replanting of damaged plant on onion (Allium cepa L.) (양파 정식시기별 서릿발 피해 방지 및 피해주 재이식 효과)

  • Kwon, Young-Seok;Choi, In-Hu;Kim, Cheol-Woo;Choi, Min-Seon;Kwak, Jung-Ho;Lim, Yong-Pyo
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.4
    • /
    • pp.313-318
    • /
    • 2015
  • In the year 2013, onions cultivation in Jeonnam province suffered by frost-pillar damage. To reveal the aspects of the cause and outbreak, we surveyed those damaged areas. Usually the frost-pillar damage occurred in February. But the outbreak aspect is so unforeseeable. In 2013, the damage was shown as 10.6% in onion fields including paddy fields, but no damage was noticed in 2014. The damage was noticed as 77.8% in paddy fields and 30.1% in upland. And, by the difference of the onion transplanting date, it occurred as 0.7% by the middle of November to the early of November, 22% by the middle of November and 69.0% by the early of December. If one performed the supplementary planting at $3^{rd}$ week of February, the highest survival percent was observed as 53.3%. If the date is early, another frost-pillar damage was occurred. If it's late, the damaged plant was perished with dry. In any case, we found improper transplanting caused the yield decrease. Therefore, we recommend the timely transplanting is the most important way for the prevention of frost-pillar damage in the onion cultivation.