Proceedings of the Korean Geotechical Society Conference (한국지반공학회:학술대회논문집)
- 2010.09a
- /
- Pages.546-552
- /
- 2010
Mechanical Behavior of Buried Pipe Line with Frost Prevention Materials
동상방지재료를 활용한 온도에 따른 매설관 거동 특성에 대한 연구
- Kang, Jae-Mo (Dept. of Infrastructure Research, KICT) ;
- Kim, Hak-Seung (Dept. of Infrastructure Research, KICT) ;
- Kim, Young-Seok (Dept. of Infrastructure Research, KICT) ;
- Lee, Jang-Keun (Dept. of Infrastructure Research, KICT) ;
- Hong, Sung-Seo (Dept. of Infrastructure Research, KICT)
- Published : 2010.09.09
Abstract
Seasonal frozen ground affects structural behavior in South Korea. Frost and heaving of seasonal frozen ground results in the critical damage of roadway, railroad, and buried pipeline. It has been widely used to substitute frost susceptible soils with granular soils. This paper presents experimental investigation on the effectiveness of soil-shredded tire and soil-expanded polystylene (EPS) mixtures to reduce frost depth and force around a buried pipeline. Experimental data such as measured temperature profile and the deformation of buried pipeline were carefully observed and provide the evidence of the effectiveness of soil mixtures.