• Title/Summary/Keyword: Frost layer

Search Result 98, Processing Time 0.022 seconds

Temperature History of Slab Concrete Depending on Insulation Curing Method in Cold Weather Concreting (한중시공시 단열양생방법 변화에 따른 슬래브 콘크리트의 온도이력 특성)

  • Kim Jong-Back;Lim Choon-Goun;Park Koo-Byoung;Kim Seoung-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.17-20
    • /
    • 2005
  • This paper reported the temperature history of concrete placed at deck plate slab under cold climate condition by varying with surface insulating type. No curing sheet and simple insulation curing including non-woven fabric, double layer bubble sheet, the combination of double layer bubble sheet and non-woven fabric dropped temperature below zero within 24 hours, which caused frost damage at early age. On the other hand, the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam maintained minimum temperature above $4^{\circ}C\;and\;8^{\circ}C$, respectively. Based on core test results compressive strength of concrete with the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam was higher than those with other curing method due to good insulation effect.

  • PDF

Earth Hummocks on the Crater Floor of Baegnokdam at Mt. Halla (한라산 백록담 화구저의 유상구조토)

  • 김태호
    • Journal of the Korean Geographical Society
    • /
    • v.36 no.3
    • /
    • pp.233-246
    • /
    • 2001
  • Topography and soil characteristics of earth hummocks are examined in the summit crater of Mt. Halla in order to evaluate their morphoclimatic significance as an indicator of a periglacial environment. The hummocks are generally oval in outline, and they have a diameter of 42 to 200 cm and a height of 9 to 27 cm Seventeen hummocks are distributed In a 5$\times$5 m quadrat at an interval of 20 to 40 cm Excavation reveals the cryoturbated soil profiles which consist of upper dark brown layer and lower brown layer. The dark brown layer has 61.8% total clay and silt content, implying Its high frost susceptibility Earth hummocks have the dry density of 0.761 to 1.009 g/㎤ the void ratio of 1420 to 2.008, and the moisture content of 24.2 to 68.8% by weight, respectively. The hummocky soils become compacted and desiccated downward. Earth hummocks are frozen as a hard solid mass during winter and early spring, and freezing fronts reach about 45 cm below their apices. The layer with high lute content appears in the upper horizon of dark brown soil. but Ice lenses are not so much segregated The moisture content of hummocky soils generally increases up to 73.9 to 118.80% for dark brown layer and 49.9 to 82.8% for brown layer during thins period Because the cohesive soil of earth hummocks indicates 72.8% of the moisture content as a liquid limit, the dark brown layer is highly fluid and consequently subject to cryoturbation processes.

  • PDF

Establishment of Database for Anti-Frost Heave Layer (동상방지층 설계를 위한 현장 계측자료의 데이터베이스(DB) 구축)

  • Lee, Bum-Woo;Kim, Nak-Seok;Nam, Young-Kug
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.90.1-90.1
    • /
    • 2010
  • 우리나라는 계절적 특성으로 인하여 겨울에서 봄에 이르기까지 도로포장의 동결 융해가 반복되어 도로 파손을 유발 시키고 있다. 동결 융해로 인한 피해를 줄이기 위하여 도로포장 설계시 동상방지층을 별도로 설치를 하고 있으나 실효성 검증 없이 무분별하게 적용되고 있어 국가적으로 예산을 낭비하고 있다. 본 연구에서는 효과적인 동상방지층의 설계를 목적으로 계측된 온도 및 함수비 데이터를 효율적으로 관리하고 모니터링하는 기반을 마련하고자 한다.

  • PDF

Effect of XPS and Polyethylene Aggregates in Model Tests for Prevention of Frost Heave in Railroad Track (철도에서의 동상방지를 위한 모형시험에서 XPS 및 PE골재의 설치 효과)

  • Kim, Donggwan;Yoon, Yeowon;Kim, Youngchin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.10
    • /
    • pp.5-13
    • /
    • 2014
  • In this research, in order to study insulation effect of commercial XPS and recycled PE aggregates for prevention of frost heave in the roadbed of railroad track from the freezing temperature, model tests were carried out in the large freezing room. For this, thermal conductivities were measured for various dry densities, water contents, temperatures and mixing ratios of PE aggregates. From the tests, it can be seen that thermal conductivities of roadbed decrease with the increase of the ratio of mixed PE aggregates. However it was sensitive to the changes of temperature and water content due to the amount of water in the voids. From the model test of railroad track, it can be seen that the time to reach $0^{\circ}C$ was longer for XPS than that for the PE aggregates. Also the test shows best insulation effect can be achieved when XPS board was installed above the PE aggregate layer rather than the opposite order.

Field Application of the Mass Concrete Using Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열보온양생공법의 한중매스콘크리트 현장적용)

  • Lee, Dong-Gyu;Kim, Jong;Kim, Ki-Hoon;Hwang, Yin-Seong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.1-4
    • /
    • 2007
  • This study investigated the applicability of insulation curing method with double layer bubble sheets to the man concrete subjected to cold weather. Temperature history of the mass concrete indicated that the highest temperature of center section was exhibited at $34^{\circ}C$ while the that of surface section was $25^{\circ}C$. Difference between center and surface was shown to be less $10^{\circ}C$ when the temperature of center section was peak section, and thereby associated temperature cracking index was calculated 1.5, and occurrence probability of temperature cracking was 5%, so there was no temperature cracking caused by internal restraint. No temperature crack was observed by naked eye. It was clear that early frost demage and temperature cracking could be restrained due to reducing temperature difference between inner part and outside in the case double bubble sheets applied to insulation curing method in cold weather. The maturity of mass concrete is higher than outside about $72\sim89^{\circ}$ DD, so it was demonstrated to prevent early frost demage and ensure strength excellently. Insulation curing method with double bubble sheets was more economic than heating curing method.

  • PDF

Evaluation of Freeze-Thaw Effect on the Modulus of Subgrade Soils from Impact Resonance Test (충격공진시험을 이용한 동결.융해에 따른 노상토의 탄성계수 평가)

  • Lee, Jae-Hoan;Kweon, Gi-Chul
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.71-77
    • /
    • 2010
  • Anti-freezing layer does not used in case of non frost heaving in subgrade soils. In this case, the modulus of subgrade soils were varied with freezing and thaw cycles under non frost heaving. That effect should be properly considered in pavement design. Impact resonance test that is nondestructive testing method was used for continuously determining the modulus of subgrade soils during freezing and thaw cycle. The modulus of subgrade soils was identical with freezing and thaw cycles under closed freezing and thaw system which is no water supplement into specimen during testing. There was also no difference in the modulus of subgrade soil between before and after freezing-thaw cycles for all specimens with different water content and density. That is thaw-weakening of subgrade soils do not occur under closed freezing and thaw system. The moduli at freezing conditions are varied with water content and density, but it can be ignored in practical design sense.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

Effect of Temperature and Plow Pan on Water Movement in Monolithic Weighable Lysimeter with Paddy Sandy Loam Soil during Winter Season

  • Seo, Mijin;Han, Kyunghwa;Jung, Kangho;Cho, Heerae;Zhang, Yongseon;Choi, Seyeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.4
    • /
    • pp.300-309
    • /
    • 2016
  • The monolithic weighing lysimeter is a useful facility that could directly measure water movement via layers, drainage, and evapotranspiration (ET) with precise sensors. We evaluated water movement through layers and water balance using the lysimeter with undisturbed paddy sandy loam soil, Gangseo soil series (mesic family of Anthraquic Eutrudepts classified by Soil Taxonomy) during winter season from Dec. 2014 to Feb. 2015. Daily ET indicated up to 1.5 mm in December and January and 2 mm in February. The abrupt increase of soil water tension at the depth of 0.1 m, when soil temperature at the same depth was below $2^{\circ}C$, was observed due to temporary frost heaving. The surface evaporation was less than reference ET below -15 kPa of soil water potential at the depth of 0.1 m. The maximum drainage rate was similar to the saturated hydraulic conductivity of a plow pan layer. Both upward and downward water movement, related to ET and drainage, were retarded by a plow pan layer. This study demonstrated that the lysimeter study could well quantify water balance components even under frost heaving during winter season and that a plow pan with low permeability could act as a boundary that affects drainage and evapotranspiration.

Evaluation of Horizontal Force on Pile Shaft Surrounded by Vertical PET Aggregate Layer for Fluid Machinery Structure Installation in Cold Region's Plant (동토 플랜트 유체기계 구조물 설치를 위한 PET 골재적용 말뚝의 주면작용 수평력 평가)

  • Ji, Subin;Jang, Sung Min;Hwang, Soon Gap;Lee, Kicheol;Kim, Dongwook
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.43-47
    • /
    • 2016
  • Pile foundations constructed on extremely cold regions cause serviceability problems of superstructures from repeated actions of ground freezing and thawing. Oil sand module plants are mainly constructed on seasonal frozen ground. Due to the freezing and thawing actions of grounds, vertical movements of piles have been observed. To solve these erratic pile movement problems, thin vertical layer of PET aggregates is installed around the pile shaft to prevent potential unfavorable pile movements. There is no known method to calculate "thin PET aggregate layer" -surrounded pile shaft resistance (capacity) against vertical loads; therefore, this experimental research is conducted. Specifically, in this study, horizontal (normal) pressures on pile shaft were assessed varying PET aggregate layer thickness based on the experiment.

Cytogenetic and Physiological Studies in Natural Populations of Torreya nucifera (비자나무 천연생집단(天然生集團)의 세포유전학적(細胞遺傳學的) 및 생리학적(生理學的) 연구(硏究))

  • Kim, Yeung Du;Kwon, Yeong Cheol
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.1
    • /
    • pp.42-54
    • /
    • 1989
  • These studies were carried out to examine the anatomical, karyological characteristics, the variation of isozymes in needle and the frost damage of tissue for the purpose of investigating the relationships among the three natural Torreya nucifera populations of Cheju-do, Namhae, and Mt. Naejang in Korea. The results obtained can be summed up as follows : 1. The numbers of endodermal cells and inner layer cells of mucilage canal of needle conductive tissue were different in each population. The number of those of Cheju-do population was the largest. 2. In somatic chromosome, Namhae population showed one more secondary constriction. The values of $b^{arm}/a^{arm}$ were the same in all the three populations, but Cheju-do population particularly showed a different minimum value. And the karyotype formulas of each population showed difference. 3. During the meiosis, each population showed no significant difference in the irregular phenomena of chromosome. 4. In isoperoxidase and esterase variations of needle, each population showed its particular number and variation of bands. Cheju-do population showed the largest number and greatest variation of bands. 5. Under the same freeging conditions, the frost damage of Mt. Naejang population was comparatively slight, and Cheju-do population suffered from a greater frost damage than the others.

  • PDF