• Title/Summary/Keyword: Frost layer

Search Result 98, Processing Time 0.025 seconds

An experimental study of frost forming on the horizontal cylinder under cross flow (직교유동 내에 놓인 수평 실린더에서 서리 생성에 관한 실험적 연구)

  • 이윤빈;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.448-456
    • /
    • 1999
  • Variations of thickness and effective thermal conductivity of frost forming on the horizontal] cylinder with respect to time were measured under cross flow. The local heat flux around the cylinder was determined by measuring the radial temperature distribution in the cylinder having small holes drilled axially in which T-type thermocouples were inserted, then by using one dimensional cylindrical heat conduction equation. The thickness and the surface temperature of the frost layer around the cylinder were measured periodically while developing the frost. Each experiment was peformed by varying the Reynolds number, the temperature, and the humidity condition. Specially the dew point temperature of the most cases was below the freezing point. Experimental data showed that the frost layers on the front and the rear surface were thicker than those on the top and the bottom one which was near the separation point. The thickness and effective thermal conductivity of the frost layer were affected by inlet air velocity, temperature, and humidity. Moreover, the effective thermal conductivity and the effective thermal resistance increase with respect to time.

  • PDF

Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition (착상조건하에서 평행 평판 열교환기의 열 및 물질전달)

  • Lee, K.S.;Lee, T.H.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

A Study on The Frost Penetration Depth of Pavement with Field Temperature Data (도로포장 현장계측 온도데이터를 이용한 도로포장체의 동결깊이 연구)

  • Shin, Eun-Chul;Lee, Jae-Sik;Cho, Gyu-Tae
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.21-32
    • /
    • 2011
  • The frost penetration depth of pavement is usually estimated from the freezing index that made temperature data analysis of 30 years and decided the thickness of anti-frost layer. The field monitoring region in study was divided into five regions by freezing index 550~650$^{\circ}C{\cdot}$day, 450~550$^{\circ}C{\cdot}$day and 350~450$^{\circ}C{\cdot}$day. Each region has three-section of road pavement such as cutting area, boundary area of cutting and banking, and lower area of banking. The field monitoring system was established both in the section of anti-frost layer and in the section without anti-frost layer. The data analysis was conducted for determination of frost penetration depth within the paved road by the field monitoring system. The result showed that The temperature of subgrade without anti-frost layer shows below zero in centigrade for the region of freezing index 550~650$^{\circ}C{\cdot}$day, up and down around zero degree in subgrade for the region of freezing index 450~550$^{\circ}C{\cdot}$day, and there is no place existed below zero degree in subgrade for the region of freezing index below 450$^{\circ}C{\cdot}$day. With comparison of field frost penetration depth for the cross-sections of pavement, the cutting area shows the greatest frost penetration depth, and less influence of frost penetration depth for the boundary area of cutting and banking, and the least influenced for the lower area of banking.

A Study of Frost Formation on Different Hydrophilic Surfaces (다른 친수성능을 가진 두 표면에서의 착상에 관한 연구)

  • 김철환;신종민;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.519-524
    • /
    • 2002
  • An experimental study has been conducted to investigate the effects of surface energy on frost formation. Test samples with two different surfaces are installed in a wind tunnel and exposed to a humid airflow. Dynamic contact angles (DCA) for these surfaces are $23^{\circ}\;and\;88^{\circ}$, respectively. The thickness and the mass of frost layer are measured and used to calculate the frost density while frost formation is visualized simultaneously with their measurements. Results show that frost density increases as time increases at specific test conditions. The air Reynolds number, the airflow humidity and the cold plate temperature are maintained at 12,000, 0.0042 kg/kg and $-21^{\circ}C$, respectively. The surface with a lower DCA shows a higher frost density during two-hour test, but no differences in the frost density have been found after two hours of frost generation. Empirical correlations for thickness, mass and density are assumed to be the functions of the test time and DCA.

Analisys on Freezing Characteristics of Pavement Layer Using the Feild Pavement Model test (현장 모형 도로 축소 실험을 이용한 포장구성층의 동결 특성 분석)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Moon, Yong-Soo;Park, Jeong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1164-1171
    • /
    • 2010
  • Korea is considered to be a seasonal frozen soil area that is thawed in the spring, and most of the area is frozen in winter as to the characteristic of geography. In the current design codes for anti-freezing layer, the thickness of anti freezing layer is calculated by freezing depth against the temperature condition. Therefore, they have a tendency of over-design and uniform thickness without the considerations of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential for studying the appropriateness and bearing capacity besides the seasonal and mechanical properties of pavement materials to take a appropriate and reasonable design of the road structure. In this research, the evaluation of frost susceptibility on subgrade, ant-freezing layer, sub base was conducted by means of the mechanical property test and laboratory field road model downed scale experiment. The temperature, heaving amount, heaving pressure and unfrozen water contents of soil samples, the subgrade, anti-freezing layer, sub base soils of highway construction site, were measured to determine the frost susceptibility.

  • PDF

The Effect of Environmental Parameters on Frost Formation on a Horizontal Cylinder (수평 실린더에서의 서리 생성에 대한 환경 변수들의 영향)

  • Lee, Yun-Bin;Ryu, In-Sang;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.253-260
    • /
    • 2002
  • It is known that frost formation on surfaces of the heat exchanger seriously affects the performance of the refrigeration system. Accordingly, defrosting should follow, and effective defrosting is possible only when both analytic tools and comprehensive experimental data on frost formation are assailable. An experimental investigation was undertaken to characterize the effect of environmental parameters on frost formation on a horizontal cylinder in cross uniform flow. Several experiments were carried out with various environmental parameters such as inlet air temperature, inlet air humidity, air velocity and cooling surface temperature. Frost thickness, mass, surface temperature and cylinder inner and outer temperature were measured at front and rear positions of the cylinder. Thickness, mass, density, and effective thermal conductivity of the frost layer were obtained from measured data and effects of environmental parameters on the frost formation were analyzed. Data from experiments were correlated using dimensionless variables.

Experimental Study for Development of Air Eject Defrost Equipment (공기분사식 제상장치 개발에 관한 실험적 연구)

  • Han, In-Geun;Kim, Chang-Yeong;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

The Freezing Characteristics of Pavement Layer Using the Field Road Model Test (현장도로 모형실험을 이용한 포장구성층의 동결 특성 분석)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.71-80
    • /
    • 2010
  • Korea is considered to be a seasonal frozen soil area that thaws in the spring, and freezes in winter. In the current design codes for anti-freezing layer, the thickness of anti-freezing layer is calculated by the depth frozen due to the temperature condition. Therefore, there is a tendency of over-design and applying uniform thickness without the consideration of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential to study the structural appropriateness of pavement layer and bearing capacity besides the seasonal and mechanical properties of pavement materials to take an appropriate and reasonable design of the road structure. In this paper, the evaluation of frost susceptibility on subgrade, ant-freezing layer, subbase was conducted by means of the mechanical characteristics and model experiment. The temperature, heaving amount, unfrozen water contents and freezing depth of soil samples, the subgrade, anti-freezing layer, subbase soils of road construction site were measured to determine the frost susceptibility.

Evaluation of Ground Water Level Effect on Frost Heaving in Road Pavements (도로 포장체에서 동상에 대한 지하수위 영향 평가)

  • Kweon, Gichul;Lee, Jaehoan
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.47-56
    • /
    • 2013
  • PURPOSES: This study is to evaluate a ground water level effect on frost heaving in road pavements. METHODS: The effects of water table on frost heaving in pavement systems were evaluated from the mechanical analysis using FROST program. The input parameters and boundary conditions were determined by considering climates, pavement sections, and material properties specially subgrade soil types in Korea. RESULTS: When the water table located above the freezing depth, amount of frost heaving caused by freezing the water in pavement itself was big enough to damage in pavement system, although pavement system consists of fully non-frost-susceptible materials with sufficient thickness of anti-freezing layer. The amount of frost heaving was decreased rapidly with increasing the distance between the water table and freezing depth. CONCLUSIONS: It was concluded that there is no engineering problems related with frost heaving in practical sense when the distance between freezing depth and water table is over 1.5m for having subgrade soils less than 50% of #200 sieve passing to meet specification on quality control in Korea.

Frost Behavior on a One-Dimensional Fin Considering Heat Conduction of Heat Exchanger Fins (열교환기 휜의 열전도를 고려한 1차원 휜에서의 착상 거동)

  • Kim, Jung-Soo;Kang, Soo-Jin;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.727-732
    • /
    • 2008
  • This paper presents a mathematical model to predict the behavior of frost formed on an one-dimensional fin of heat exchanger, considering fin heat conduction under frosting conditions. The computational domain consists of air-side, the frost layer, and fin region, and they are coupled to the frost layer. The frost behavior is more accurately predicted with fin heat conduction considered (Case A) than with constant fin surface temperature assumed (Case B). The results indicate that for Case B, the frost thickness and heat transfer are overpredicted in most regions of the fin, as compared with those for Case A. In addition, for Case A, the maximum frost thickness varies little with the fin length variations, and the extension of the fin length after 30mm contributes insignificantly to heat transfer.