• Title/Summary/Keyword: Frost Test

Search Result 173, Processing Time 0.023 seconds

Evaluation of Frost Heave Prediction and Frost Susceptibility in Sample using JGS Test Method (일본 동상성판정기준을 적용한 시료의 동상예측 및 동상성 평가)

  • Kim, Young-Chin;Hong, Seung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.926-931
    • /
    • 2008
  • This paper show two different standardized test methods(Japanese Geotechnical Society; JGS 2003). One test is a "Test Method for Frost Heave Prediction Test, JGS 0171-2003", and the other test is a "Test Method for Frost Susceptibility, JGS 0172-2003". The purpose of this test is to obtain the freezing rate(freezing speed), frost heave ratio(heave to sample height), frost heave rate(heaving speed), and other parameters to be used for frost heave prediction and determine the frost susceptibility by freezing test with water intake. This method shall be used to predict the frost heave in frozen ground and evaluate the frost susceptibility of natural and replacement materials.

  • PDF

A Study of Frost Formation on Different Hydrophilic Surfaces (다른 친수성능을 가진 두 표면에서의 착상에 관한 연구)

  • 김철환;신종민;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.519-524
    • /
    • 2002
  • An experimental study has been conducted to investigate the effects of surface energy on frost formation. Test samples with two different surfaces are installed in a wind tunnel and exposed to a humid airflow. Dynamic contact angles (DCA) for these surfaces are $23^{\circ}\;and\;88^{\circ}$, respectively. The thickness and the mass of frost layer are measured and used to calculate the frost density while frost formation is visualized simultaneously with their measurements. Results show that frost density increases as time increases at specific test conditions. The air Reynolds number, the airflow humidity and the cold plate temperature are maintained at 12,000, 0.0042 kg/kg and $-21^{\circ}C$, respectively. The surface with a lower DCA shows a higher frost density during two-hour test, but no differences in the frost density have been found after two hours of frost generation. Empirical correlations for thickness, mass and density are assumed to be the functions of the test time and DCA.

Characteristics and Trends of Spatiotemporal Distribution of Frost Occurrence in South Korea for 21 Years (21년간 한국의 서리발생 시·공간 분포 특성과 경향)

  • Jo, Eunsu;Kim, Hae-Min;Shin, Ju-Young;Kim, Kyu Rang;Lee, Yong Hee;Jee, Joonbum
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.2
    • /
    • pp.83-94
    • /
    • 2022
  • In order to actively prepare to frost damage that occurs in the process of growing crops, the spatial and temporal distribution of frost occurrence in South Korea was derived using frost observation data from 20 regions over the past 21 years (2000~2020). The main products are the number of frost days, first frost day, and last frost day by region. And the climatic trends of these results were identified by performing the Mann-Kendall trend test and Sen's slope estimator. In South Korea, a lot of frost occurs in the inland area to the west of the Taebaek and Sobaek Mountains. Relatively closer to the coastal area, the number of frost days is small, the first frost day is slow, and the last frost day is early. The east coast region has fewer frost days, the first frost day is later, and the last frost day is earlier than the west coast region. The southern sea, the southeastern sea region, and the island region rarely experience frost. As a result of the annual time series trend analysis, although South Korea is a country where climate warming is progressing, there was no trend in reducing the number of frost days and slowing the first frost day, and it was found that the last frost day is delayed by 0.5 days per year.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

Stiffness change measurement for subgrade soils at freezing and thawing using impact resonance test (충격공진시험을 이용한 노상토의 동결.융해시 강성도 변화 측정)

  • Lee, Jae-Hoan;Kweon, Gi-Chul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.686-691
    • /
    • 2009
  • Damage due to frost action in pavement structure system is creating either frost heave or stiffness-weakening of subgrade soil follow melting. The formation of ice lenses requires a frost-susceptible soil, freezing temperatures, and continuous water supply. Eliminating one of these conditions suffices to significantly reduce the intensity of frost action. It is important to know characteristics of subgrade soil in frost susceptibility or decide degree of freezing permission. Also, study on the stiffness variation of subgrade soil during freezing and thawing cycle is very important. In this study, Impact resonance test for subgrade soil at freezing and thawing confirms that is applied for.

  • PDF

An Experimental Study on Frost Heaving Characteristics of Soil Stabilized with the Additives (안정처리토의 동상특성에 관한 실험적 연구)

  • Kim, Jae-Young;Ju, Jae-Woo;You, Byung-Ok;Yang, Sung-Kee
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.215-218
    • /
    • 2003
  • In order to study the frost heaving characteristics of soil stabilitized with a quick lime, a cement and a briquette ash, frost heaving tests were performed with 2 kinds of soil sampled at Chonbuk-Do area. Frost heaving of no-stabilizing soil compacted with water content greater than optimum water content was increased as the frost period was increased but in case of samples with water content smaller than optimum water content, the frost period gave no affect about increase and decrease of the frost heaving. Both frost heaving of stabilizing and no-stabilizing soil with water content greater than optimum water content was decreased with the increase of the repetition number of freezing and thawing. There was no increase or decrease of frost heaving in the frost heaving test after 5 times of freezing and thawing.

  • PDF

Experimental Evaluation on JGS Frost Susceptibility Testing Method (일본 동상민감성 판정 기준에 관한 고찰)

  • Jangguen Lee;Hyunwoo Jin;Zheng Gong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.7
    • /
    • pp.21-27
    • /
    • 2024
  • Frost heave, a significant engineering aspect of frozen ground, leads to various damages in Korea during the winter. Both the United States and Japan, encompassing regions with frozen ground, have actively researched frost heave and possess standardized experimental methods. Particularly, the Japanese Geotechnical Society (JGS) has introduced a frost heave standard testing method, offering the advantage of relatively simple specimen preparation and experimental procedures. However, issues persist regarding the ambiguous engineering interpretation of frost heave test results and the lack of clear criteria for frost heave susceptibility assessment. This paper presents laboratory testing results following the JGS testing method on sand and silt mixtures using a triaxial temperature-controllable cell, and thoroughly analyzes the frost heave rate calculation process. Furthermore, it evaluates the applicability of frost heave susceptibility criteria proposed in the United States to frost heave rates based on the JGS testing method.

Correlations of Frost Properties Considering the Environmental Parameters over a Cold Flat Plate (수평편판에서의 착상인자를 고려한 서리 물성치의 상관식)

  • Lee, Kwan-Soo;Kim, Yong-Chul;Jhee, Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1046-1052
    • /
    • 2001
  • This study has been performed experimentally to measure the frost properties over a cold flat plate in order to obtain the correlations of the frost properties with various environmental parameters. Correlations of the frost surface temperature, thickness, density, and thermal conductivity are presented along with the experimental results as a function of environmental parameters, distance from the leading edge of test plate, and time. These correlations can be used to predict the frost properties with a maximum error of 8% in the following ranges : air temperature 15∼25$\^{C}$, relative humidity 60∼80%, air velocity 1∼3m/s and cooling plate temperature -15∼-25$\^{C}$.

Evaluation on the Reliability of Frost Susceptibility Criteria (동상민감성 판정 기준 신뢰성에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.12
    • /
    • pp.37-45
    • /
    • 2017
  • Structural instability and damage are caused by frost heave during the winter when atmospheric temperature maintains below $0^{\circ}C$. Frost heave is the most representative engineering characteristics of frozen ground and there are various frost susceptibility criteria. Frost susceptibility criteria can be roughly divided into three categories. First, frost susceptibility is determined from particle size distribution, which is practically useful and many countries are adopting. In this paper, several particle size distributions (PSDs) are applied to the frost susceptibility criteria but PSD seems to be not enough to determine whether soils are frost susceptible. Second, it is judged from laboratory frost heave testing results. Laboratory frost heave tests were performed with newly developed thermal controlled triaxial cell and the reliability of frost susceptibility criteria is evaluated. New testing apparatus and method are suitable to meet the existing frost susceptibility criteria. Third, it is compositive frost susceptibility criteria envelope including the particle size distribution, soil classification, and frost heave test. The compositive frost susceptibility criteria envelope should be supplemented based on additional data on various soil types.

Analysis Study of Performance of CO2 Microchannel Evaporator According to Frost Growth (서리성장에 따른 이산화탄소용 마이크로채널 증발기의 성능에 관한 해석적 연구)

  • Shin, Eun-Sung;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.724-732
    • /
    • 2012
  • The microchannel evaporator with louver fin using carbon dioxide are analyzed according to the frost growth. To predict the performance of microchannel evaporator with the frost growth under low temperature, the simulation condition of previous studies was applied. As a result, the frost thickness increases and its increasing rate is reduced when the operating time increases. Frost thickness increases gradually below the quality of 0.74, and then it decreases rapidly. In addition, the frost growth of present model under same surface temperature is very similar trends with Moallem's test results. In case of low temperature application, the dimensionless frost thickness increases dramatically and it is about 0.86 after 10 minutes.