• Title/Summary/Keyword: Frictional characteristics

Search Result 469, Processing Time 0.032 seconds

A Study on the Lunar Ground Temperature Profile for Investigation of Possible Condition of the Ice Layer Existence in Sub-surface of the Moon (달 지하 얼음 층 존재 가능조건 검토를 위한 달 지반 온도 프로파일 산정 연구)

  • Go, Gyu-Hyun;Lee, Jangguen;Shin, Hyu-Soung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.801-809
    • /
    • 2019
  • NASA's lunar polar exploration mission in 2009 confirmed the presence of ice-layer in the permanently shadowed regions (PSR) of the moon. Since then, studies have been actively conducted to evaluate the ground characteristics for exploring the ice-layer in the polar regions of the Moon. In this study, transient heat transfer analysis for the lunar ground was conducted to predict the ground's temperature that varies with the time and location. As a result of the numerical analysis, it was confirmed that the temperature under the lunar ground converged to below the ice sublimation reference temperature (≒112 K) at above 86° latitude. This model enabled us to identify the regions where there is a high possibility of ice being buried. Besides, we found that the ice-layer in the shallow region, where the temperature deviation is significant, makes ground temperature distribution heterogeneous. Lastly, this study suggested the maximum allowable frictional heat of a drill bit that can preserve the phase of buried ice.

Experimental Study on Vibration Reduction Characteristics of Polymer Concrete (폴리머 콘크리트의 진동저감 특성에 대한 실험적 연구)

  • Kim, Jeong-Jin;Shim, Hak-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.58-65
    • /
    • 2019
  • Polymer concrete is expected to be widely used as a building material because it has a shorter hardening time and excellent compression, tensile, bending, bond strength, frictional resistance and abrasion loss compared to general concrete. The polymer concrete has excellent vibration damping performance and research on the use of various reinforcing materials is being conducted. However, in order to completely replace the general concrete and the general anti-vibration reinforcement, such polymer concrete requires an overall review of vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio were compared with those of general concrete. It was appeared that compression, tensile, bending and bond strengths of polymer concrete by epoxy mixing were significantly higher than those of general concrete. Especially, the tensile strength was more than 4 ~ 6.5 times. Based on the basic physical properties of polymer concrete, the damping ratio, which is a dynamic characteristic according to the epoxy mixing ratio, was derived through analytical models and experiments. As a result, the dynamic stiffness of polymer concrete was 20% higher than that of general concrete and the loss rate was about 3 times higher.

Difference of holding power of concrete weight used in shellfish shell fishery by its shape characteristics (패류껍질어업에서 사용 중인 멍의 형태적 특성에 따른 고정력의 차이)

  • LEE, Gun-Ho;CHO, Sam-Kwang;KIM, In-Ok;CHA, Bong-Jin;JUNG, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • In this study, the differences of holding power according to the shape and weight distribution of concrete weight used in shellfish shell fishery were investigated through the experiments. To investigate the differences in shape, five bar-shaped concrete weights with the same length and different cross-sectional shapes were produced. The sectional shape of each weight was square, triangle, circle, small cross, and large cross (SQ, TR, CI, CR-S, CR-L). Ten rectangular parallelepiped weights with different bottom area and cross-sectional area were produced. To investigate the differences by the weight distribution, the holding power on the square model (SQ) with six 50 g weights at different positions was investigated. All the holding power was obtained by measuring the tensile force generated when the concrete weight was pulled at a constant speed on the sand. As a result, there were no differences in holding power between the ten rectangular weights. However, the experiment on weights with different cross-sectional shapes showed differences in holding power. The holding power was higher in the order of CR-L > CR-S > CI > TR > SQ. In the weight distribution test, the holding power was higher as the front side of the weight was heavier. Generally, the frictional force is the same even if the shape is different, when two objects have the same value in the weight and the roughness. On the other hand, it seems to have a large impact when the shape of the bottom is deformed in the course of pulling the object. Particularly, the larger the degree of protrusion like cruciform weights, the more the holding power increased while deeply digging the bottom. It is also likely that the holding power increases as the front weight increases.

Vertical Load Transfer Mechanism of Bucket Foundation in Sand (사질토 지반에 설치된 버킷기초의 수직 하중전이 특성)

  • Park, Jeong-Seon;Park, Duhee;Yoon, Se-Woong;Jang, Hwa-Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.7
    • /
    • pp.29-39
    • /
    • 2015
  • The vertical load imposed on the bucket foundation is transferred from the soil inside the bucket to the bottom of the foundation, and also to the outer surface of the skirt. For the design of a bucket foundation installed in sand, the vertical load transfer characteristics have to be clearly identified. However, the response of bucket foundations in sand subjected to a vertical load has not been investigated. In this study, we performed two-dimensional axisymmetric finite element analyses and investigated the vertical load transfer mechanism of bucket foundation installed in sand. The end bearing capacity of bucket foundation is shown to be larger than that of the shallow foundation, whereas the frictional resistance is smaller than that for a pile. The end bearing capacity of the bucket foundation is larger than the shallow foundation because the shear stress acting on the skirt pushes down and enlarges the failure surface. The skin friction is smaller than the pile because the settlement induces horizontal movement of the soil below the tip of the foundation and reduces the normal stress acting at the bottom part of the skirt. The calculated bearing capacity of the bucket foundation is larger than the sum of end bearing capacity of shallow foundation and skin friction of pile. This is because the increment of the end bearing capacity is larger than the reduction in the skin friction.

Software Development of the Traffic Noise Prediction Based on the Frictional Interaction between Pavement Surface and Tire (포장노면과 타이어간의 마찰음 분석을 통한 교통소음예측 소프트웨어 개발)

  • Mun, Sung-Ho;Lee, Kwang-Ho;Cho, Dae-Seung
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.67-75
    • /
    • 2011
  • Domestic economic development, industrialization, and urbanization have brought along not only increased highway traffic but also elevated traffic noise levels. Thus, it is necessary to accurately predict the traffic noise levels in order to address the public demand of alleviating the noise levels in urban areas. In this study, the method of evaluating the sound power level of road traffic was investigated in terms of considering the types of road surface and vehicle, based on previous researches. Regarding CPX (Close Proximity Test) and Pass-by test, the measured noise data of Test Road of Korea Highway Corporation were utilized in order to construct the database of sound power levels of various vehicles. Specifically, the 38 noise measurement and analysis in 1/1-octave band frequencies at 12 pre-selected sites were carried out, considering topography and road surface. Finally, the comparison study was conducted between predicted and measured data in terms of traffic noise. The traffic noise prediction was based on the KRON (Korea Road Noise) program, which was developed being equipped wit 3-dimensional GUI. In addition, the traffic noise characteristics were evaluated in terms of vehicle types and pavement surface conditions.

The Slope Stabilization of Solid Waste Landfill Liner System (폐기물매립장의 사면차수체계 안정화 연구)

  • Shin, Eunchul;Kim, Jongin;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.21-28
    • /
    • 2009
  • As the natural aggregates such as sand and clay are getting exhausted, the quantity of utilizing geosynthetics is being increased in the solid waste landfill. Especially, the waste landfills have been constructed at the gorge in the mountainous area and reclaimed land from the sea in the Korean Peninsula. Those areas are not favorable for construction of waste landfill in geotechnical engineering aspect. In this study, the frictional characteristics of geosynthetics that used in the waste landfill were estimated. Then, the studies of the behavior of geosynthetics and stability of LDCRS (Leachate Detection, Collection, and Removal System) of side slope were conducted in the waste landfill by means of the pilot test, and numerical analysis. Geocomposite which is combined type or separated type is influenced on the strain itself, and also implicated in the stress and strain of geomembrane at the lower layer. The strain on the combined type of geocomposite is about 50% smaller than that of the separated type at the side slope. The lateral displacement and settlement of top at the slope with the separated type are three times greater than that of the combined type. In the numerical analysis, discontinuous plans in between ground and geosynthetic, geosynthetic and geosynthetic, goesynthetic and waste have been modeled with the interface element. The results gave a good agreement with the field large-scale model test. The relative displacements of geosynthetics were also investigated and hence the interface modeling of liner system is appropriate for analysis of geosynthetics liner system in the waste landfill.

  • PDF

Study on Softness of an EO Adducted Amine Oxide Zwitterionic Surfactant (EO가 부가된 아민 옥사이드 양쪽성 계면활성제의 유연력에 관한 연구)

  • Kim, JiSung;Mo, DaHee;Lee, JinSun;Park, JunSeok;Han, DongSung;Lim, JongChoo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.960-968
    • /
    • 2012
  • In this study, the measurement of physical properties of 3 different ethylene oxide adducted zwitterionic surfactants were measured such as critical micelle concentration, surface tension, interfacial tension, contact angle, viscosity and foam stability. Also, the dual function characteristics of the zwitterionic surfactants were investigated by determining an isoelectric point, which were obtained using zeta potential measurement and QCM (quartz crystal microbalance) experiments. The isoelectric point of the synthesized zwitterionic surfactant determined by zeta potential measurement was close to that obtained by QCM experiment and both results have shown almost the same trend as that determined by the frictional property measured using an automated mildness tester. In particular, it has been observed that all three surfactants used during this study provide better softening effect at a pH of neutral condition than at an acidic or an alkaline condition. This result indicates that the synthesized surfactants act as a cationic surfactant at a pH of neutral condition and thus provide good softening effect during a rinsing cycle in the detergency process.

Study on Changes of Hair and Scalp Characteristics by Keratin Peptides (케라틴 펩타이드에 의한 모발 및 두피 특성 변화 연구)

  • Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.4
    • /
    • pp.353-361
    • /
    • 2019
  • Using Fervidobacterium islandicum AW-1, keratin peptides were produced and confirmed factors related to the scalp and hair. The cytotoxicity and proliferation tests as a function of the concentration of the keratin peptide did not show toxicity and effect on the cellular proliferation in the immortalized human hair dermal papilla cell line. Hair shampoos and hair essences containing keratin peptides were produced, and conducted human patch test. Result showed no skin irritation. The shampoo and the essence were apploed to 2 groups of 30 healthy adults for 4 weeks and showed statistically significant positive results for gloss, hair loss, scalp trouble, and hair roughness by visual assessment. The scalp water content was significantly increased after 2 and 4 weeks compared to before using the shampoo or the essence. Trans-epidermal water loss (TEWL) and the sebum secretion amount in the scalp were significantly decreased after 4 weeks compared to before. The frictional force against combing before and after using the hair shampoo and the essence for normal hair tress and damaged hair tress was significantly changed. The combing force was increased for normal hair tress and decreased for damaged hair tress. In conclusion, we suggest that keratin peptides are appropriated as cosmetic ingredients to be used in hair and scalp related products.

Characteristics of velocity-dependent shear behavior of saw-cut rock joints at different shear velocities (편평한 암석절리면의 속도 의존적 전단거동 특성)

  • Park, Byung-Ki;Lee, Chang-Soo;Jeon, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.121-131
    • /
    • 2007
  • Recently, the probability of rock joints being exposed to free faces is getting higher for the scale of rock mass structures gets larger. Also, the frequency of occurring dynamic events such as earthquakes and blasting has been increasing. Thus, the shear behavior of rock joints under different conditions needs to be investigated. In this study, a series of direct shear tests were carried out under various conditions to examine the velocity-dependent shear behavior of saw-cut rock joints. Two types of direct shear test were carried out. The first was to examine the velocity-dependent shear behavior of saw-cut rock joints at seven different shear velocities, each with three different normal stresses. The second was to examine the shear behavior of saw-cut rock joints when three different instantaneous shear velocities changed. As a result, the coefficient of friction was affected by normal stress. The breakpoint velocity, the point when the change of shear velocity starts to affect the frictional behavior, became lower as normal stress increased. Also, as the shear velocity became lower, the degree of stress-drop on stick-slip behavior became larger. As a result of examining the changes of friction coefficient, velocity weakening (decrease of friction coefficient) was observed. The decrement of friction coefficient due to the changes of shear velocity under slow shear velocity was larger than that under fast shear velocity.

  • PDF

Measurement of an Isoelectric Point and Softness of a Zwitterionic Surfactant (양쪽성 계면활성제의 등전점 및 유연력 측정에 관한 연구)

  • Lim, Jongchoo;Kim, Jisung;Mo, Dahee;Lee, Jinsun
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.112-118
    • /
    • 2012
  • In this study, physical properties of synthesized DE7-OSA82-AO and DEP52-OSA82-AOQ82 zwitterionic surfactants were measured such as critical micelle concentration, surface tension, interfacial tension, contact angle and viscosity. Phase behavior study was also performed. The dual function characteristics of a zwitterionic surfactant were investigated by determining an isoelectric point, which was attained using zeta potential measurements and QCM (quartz crystal microbalance) experiments. The isoelectric point of DE7-OSA82-AO surfactant determined by the zeta potential measurement and QCM experiment was about 7.2 and 7.4, respectively. On the other hand, the isoelectric point of DEP52-OSA82-AOQ82 surfactant determined by the zeta potential measurement and QCM experiment was about 10.9 and 11.0, respectively. The frictional property measured using an automated mildness tester showed that DE7-OSA82-AO surfactant can provide a good softening effect at an acidic or neutral condition. On the other hand, DEP52-OSA82-AOQ82 was found to provide a good softening effect to a fabric surface at a pH below its isoelectric point of 11.