• 제목/요약/키워드: Friction heat

검색결과 947건 처리시간 0.025초

적층형 판 열교환기의 U턴부 유동해석 (An analysis of fluid flow In U-bend area of laminated plate heat exchanger)

  • 이관수;박철균;정지완
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.348-357
    • /
    • 1998
  • The flow characteristics inside U-bend tube of the laminated plate heat exchanger were numerically investigated. The behavior of fluid flow, and the variations of the faulty area and friction factor are examined according to the distance between the span and the wall and the diameter of the round attacked to the end of span. The results show that the diameter(d) of the round attached to the span is mainly associated with the smooth circulation of fluid flow rather than the size of faulty area and the friction factor. As the distance($\ell$) between the span and the wall decreases, the faulty area decreases, however the friction factor dramatically increases. It is also found that one can obtain a good result in the view of the flow characteristics and pressure drop at d=7.5mm and $\ell$=30.5mm.

  • PDF

An Experimental Studies on Heat Transfer and Friction Factor in a Square Channel with Varying Number of Ribbed Walls

  • Oh Se-Kyung;Kim Won-Cheol;Ahn Soo-Whan;Kang Ho-Keun;Kim Myoung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.281-289
    • /
    • 2005
  • An experimental study on the heat transfer and friction characteristics of a fully developed turbulent air flow in a square channel with $45^{\circ}$ inclined ribs on one, two, and four walls is reported. Tests were performed for Reynolds number ranging from 7,600 to 24,900. The pitch-to-rib height ratio, p/e, was kept at 8 and rib height-to-channel hydraulic diameter ratio, $e/D_h$, was kept at 0.0667. The heat transfer coefficient and friction factor values were enhanced with the increase in the number of ribbed walls. Results of this investigation could be used in various applications of internal channel turbulent flows involving different number of roughened walls.

확대모형 열교환기를 이용한 공기측 열전달 성능에 관한 연구 (A Study on Beat Transfer Characteristics in the Air Side of Large-scaled Heat Exchanger)

  • 변주석;이진호;홍만기;전창덕
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.1032-1041
    • /
    • 2005
  • This study is performed to investigate the heat transfer characteristics of heat exchanger according to the arrangement of fins as well as fin configuration by using the four times enlarged model. Friction factor, Colburn j factor and goodness factors are compared to each other to estimate performance of each case for 4 different kinds of fins, which are plain, single side slit, double side slit and louver fin. Results show that heat transfer would be altered by fin arrangement and that friction loss is more affected by fin configurations than by the fin arrangements. In particular, heat transfer depends more on the shape of front row than that of rear row. The heat transfer rate of combined fin arrangement increases a lot more under the same pressure drop than that of conventional fin arrangement. This indicates that the heat exchanger of higher efficiency would be designed by the proper combination of fins, of different shapes.

발포 알루미늄이 삽입된 환형관에서의 열전달 및 유동특성 (Heat Transfer and Flow Characteristics in an Annulus Filled with Aluminum Foam)

  • 노주석;한영희;이계복;이충구
    • 에너지공학
    • /
    • 제15권1호
    • /
    • pp.60-66
    • /
    • 2006
  • 발포 알루미늄이 삽입된 환형관에서의 유동과 대류 열전달 특성을 실험적 연구를 수행하여 분석하고 heat sink로서의 실현 가능성을 검토하였다. 다른 기공밀도를 갖는 두 종류의 발포 알루미늄을 사용하여 유동과 열전달 특성을 파악하고 마찰계수와 열전달 관련 Nusselt수를 Darcy 수, Reynolds수, Prandtl수의 함수로 상관식을 구하였다. 발포 알루미늄이 없는 경우에 비해 마찰계수는 증가하지만 Nusselt수에서도 6에서 10배의 증가를 나타낸다. 따라서 열교환기의 크기가 제한되는 경우 열교환기에 발포알루미늄을 삽입하면 전열면적을 감소시킬 수 있으므로 열교환기를 소형화할 수 있다.

미시적/준미시적 방법을 이용한 자동차용 열교환기 해석기법 (A Numerical Process for the Underhood Thermal Management with the Microscopic and Semi-microscopic Heat Transfer Method)

  • 이상혁;김주한;이나리;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.75-79
    • /
    • 2008
  • In this study, the numerical process for analyzing the automotive louver fin heat exchanger was developed with a 3D microscopic and semi-microscopic analysis. In the microscopic analysis, the simulation with the detailed meshes was performed for obtaining the characteristics of the heat exchanger. From this simulation, the numerical correlations of the heat transfer and flow friction were obtained. In the semi-microscopic analysis, the Semi-microscopic Heat Exchanger (SHE) method, which is characterized by a conjugate heat transfer and porous media analysis was used with the numerical correlation from the microscopic analysis. This analysis predicted the flow and heat transfer characteristics of the louver fin heat exchanger in the wind tunnel and vehicle. In the design of the louver fin heat exchanger, this numerical process can predict the performance and characteristic of the louver fin heat exchanger.

  • PDF

휜-히트파이프로 구성된 채널에서 히트파이프의 엇갈림배열에 따른 유동 및 열전달 특성 (Flow and Heat Transfer Characteristics due to Staggered Arrangement of Heat Pipes in Channels with Heat Pipes and Fins)

  • 김성훈;진윤근;김철주
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.871-879
    • /
    • 2002
  • The characteristics of flow and heat transfer in the heat exchanger of heat pipes with fins have been studied numerically for cooling enhancement of electronic components of KTX (Korea Train eXpress). Numerical analysis and methodology have been conformed by comparing the experimental results for inlined array of heat pipes. The staggered arrangement of heat pipes has been proposed in order to achieve heat transfer enhancement. As results, the geometry change to the staggered array is conformed to increase the heat transfer of the system accompanied by an increase of pressure drop. The current results of friction factor and Colburn j factor are presented in terms of Reynolds number and staggered distance, and are expected to use for design and manufacture of such a system.

수차용 봉수장치의 마찰.마모특성에 관한 실험적 연구 (Experimental Study on the Friction and Wear Characteristics of Contact Sealing Unit for a Water Turbine)

  • 김청균;신인철;임광현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.515-518
    • /
    • 2006
  • This paper presents the friction and wear characteristics of contact type sealing unit for a water turbine of a small hydro-power generation, which Is to stop a leakage of a circulating water from a outside of an impeller to an inside of a rolling bearing. The surface wear strongly affect to the seal life of a mechanical face seal. In this study, the hardness of a stainless steel in which is a heat-treated is 892.8 in Vickers hardness and the hardness of silicone carbide of SiC is 714.1 in Vickers hardness. The surface hardness of a heat-treated stainless steel is 25% high compared with that of a ceramic material of SiC. The contact modes of rubbing surfaces aye a dry friction a water film friction and a mixed friction that is contaminated by a dust, silt and moistures, etc. These two factors of a contact rubbing modes and a material property are very important parameters on the tribological performance such as a friction and wear between a seal ring and a seal seat. The experimental result shows that the surface hardness of a seal material is very important on the friction coefficient and a wear volume. Thus, the results recommend higher hardness of a seal material, which may reduce a friction loss and increase a wear life of primary seal components

  • PDF

열화된 스테인리스강의 마모특성에 관한 연구 (A Study on Wear Characteristics of Degraded Stainless Steel)

  • 조승덕;안석환;남기우
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.21-30
    • /
    • 2017
  • This study deals with the characteristics of degraded stainless steel. Stainless steel is heat treated to ensure mechanical properties when designing or manufacturing machinery parts or equipment. In this study, the mechanical properties and wear characteristics of three kinds of stainless steels after artificially heat-treated at 753 K~993 K, where chrome depletion occurs near the grain boundary, were evaluated. The microstructure and fracture surface were also observed. From the results, friction coefficient and wear loss decreased with increasing the heat treatment temperature regardless of the type of stainless steel. Also, as the tensile strength increased, the friction coefficient and wear loss decreased. Wear loss showed proportional to a tendency to increase with increasing friction coefficient.

채널유동에서 거친벽면이 열전달에 미치는 효과 (Effects of Rough Surfaces on Heat Transfer in Channel Flow)

  • 안수환
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.30-35
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one wall roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at $e/D_e=0.0476$, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicate that the triangular type rib has a substantially higher efficiency index than any other ones in the range we studied.

  • PDF

기관배기 밸브용 강 ( SCr4-21-4N , SUH3-21-4N ) 의 마찰압접과 열처리에 관한 실험적 연구 (An Experimental Study on Friction Welding and Heat Treatment of Engine Exhaust Valve Steels ( SCr4-21-4 N , SUH3-21-4-N)

  • 오세규
    • 수산해양기술연구
    • /
    • 제14권2호
    • /
    • pp.79-87
    • /
    • 1978
  • 기관밸브용접 SCr4-21-4N 및 SUH3-21-4N을 연구선정된 최적마찰압접조건 하에서 마찰압접을 하고 이때 생기는 압접부의 잔류응력 및 경도의 peak 등 압접결함의 제거 및 압접성능개선을 위한 열처리에 관하여 실험연구한 결과 다음과 같은 결론을 얻었다. (1) 배기 valve용강 SCr4-21-4N 및 SUH3-21-4N의 마찰압접을 위한 최적조건으로서 회전수 3,000rpm, 마찰가열압 p 하(1)=8 kg/mm 상(2), upset 압 p 하(2)=20 kg/mm 상(2), 압접가열시간 t 하(1)=3초, upset 시간 2.5초를 선정한 것이 매우 타당함이 실험적으로 입증되었다. (2) 이종재질 SUH3-SUH31, SCr4-SUH31, SCr4-SUH3, SUH3-CRK22, SCr4-21-4N 및 SUH3-21-4N의 마찰압접에 관한 저자의 종래 연구와 본연구 결과는 압접부의 압접 특성이 서로 매우 일치하였다. (3) SCr4-21-4N 및 SUH3-21-4N의 마찰압접부의 잔류응력 및 전도의 peak를 제거하기 위한 최적열처리조건은 $600^{\circ}C$$\times$30min.$\times$room air cooling의 normalizing임이 확인되었다. (4) 이때 열처리 후에는, 열처리전의 인장강도의 약 20%가 감소했으나, 파단 위치는 열영향부로부터 모재 SCr4 및 SUH3 측으로 이동하였다. (5) 상기 최적조건 하에서 마찰압접되고 열처리된 압접부의 현미경 조직검사 결과, 압접부가 매우 좁고 압접결함이 없으며, 치밀하고 조밀한 조직의 우수한 압접이었음이 확인되었다. (6) 상기 최적조건은, 기관 valve 생산을 위한 타이종재질의 마찰압접조건으로도 응용될 수 있을 것이다.

  • PDF