• Title/Summary/Keyword: Friction

Search Result 8,289, Processing Time 0.052 seconds

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

CO2 Exchange in Kwangneung Broadleaf Deciduous Forest in a Hilly Terrain in the Summer of 2002 (2002년 여름철 경사진 광릉 낙엽 활엽수림에서의 이산화탄소 교환)

  • Choi, Tae-jin;Kim, Joon;Lim, Jong-Hwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.70-80
    • /
    • 2003
  • We report the first direct measurement of $CO_2$ flux over Kwangneung broadleaf deciduous forest, one of the tower flux sites in KoFlux network. Eddy covariance system was installed on a 30 m tower along with other meteorological instruments from June to August in 2002. Although the study site was non-ideal (with valley-like terrain), turbulence characteristics from limited wind directions (i.e., 90$\pm$45$^{\circ}$) was not significantly different from those obtained at simple, homogeneous terrains with an ideal fetch. Despite very low rate of data retrieval, preliminary results from our analysis are encouraging and worthy of further investigation. Ignoring the role of advection terms, the averaged net ecosystem exchange (NEE) of $CO_2$ ranged from -1.2 to 0.7 mg m$^{-2}$ s$^{-1}$ from June to August in 2002. The effect of weak turbulence on nocturnal NEE was examined in terms of friction velocity (u*) along with the estimation of storage term. The effect of low uf u* NEE was obvious with a threshold value of about 0.2 m s$^{-1}$ . The contribution of storage term to nocturnal NEE was insignificant; suggesting that the $CO_2$ stored within the forest canopy at night was probably removed by the drainage flow along the hilly terrain. This could be also an artifact of uncertainty in calculations of storage term based on a single-level concentration. The hyperbolic light response curves explained >80% of variation in the observed NEE, indicating that $CO_2$ exchange at the site was notably light-dependent. Such a relationship can be used effectively in filling up the missing gaps in NEE data through the season. Finally, a simple scaling analysis based on a linear flow model suggested that advection might play a significant role in NEE evaluation at this site.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Effects of Limestone Powder and Silica Fume on the Hydration and Pozzolanic Reaction of High-Strength High-Volume GGBFS Blended Cement Mortars (고강도 고함량 고로슬래그 혼합 시멘트 모르터의 수화 및 포졸란 반응에 미치는 석회석 미분말과 실리카퓸의 영향)

  • Jeong, Ji-Yong;Jang, Seung-Yup;Choi, Young-Cheol;Jung, Sang-Hwa;Kim, Sung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • To evaluate the effects of limestone powder and silica fume on the properties of high-strength high-volume ground granulated blast-furnace slag (GGBFS) blended cement concrete, this study investigated the rheology, strength development, hydration and pozzolanic reaction characteristics, porosity and pore size distribution of high-strength mortars with the water-to-binder ratio of 20, 50 to 80% GGBFS, up to 20% limestone powder, and up to 10% silica fume. According to test results, compared with the Portland cement mixture, the high-volume GGBFS mixture had much higher flow due to the low surface friction of GGBFS particles and higher strength in the early age due to the accelerated cement hydration by increase of free water; however, because of too low water-to-binder ratio and cement content, and lack of calcium hydroxide content, the pozzolanic reactio cannot be activated and the long-term strength development was limited. Limestone powder did not affect the flowability, and also accelerate the early cement hydration. However, because its effect on the acceleration of cement hydration is not greater than that of GGBFS, and it does not have hydraulic reactivity unlikely to GGBFS, compressive strength was reduced proportional to the replacement ratio of limestone powder. Also, silica fume and very fine GGBFS lowered flow and strength by absorbing more free water required for cement hydration. Capillary porosities of GGBFS blended mortars were smaller than that of OPC mortar, but the effect of limestone powder on porosity was not noticeable, and silica fume increased porosity due to low degree of hydration. Nevertheless, it is confirmed that the addition of GGBFS and silica fume increases fine pores.

Soil Mechanical Properties and Stability Analysis on Fill Slope of Forest Road (임도성토사면(林道盛土斜面)의 토질역학적(土質力學的) 특성(特性)과 안정해석(安定解析))

  • Ji, Byoung Yun;Oh, Jae Heun;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.275-284
    • /
    • 2000
  • This study was carried out to analyze the mechanical properties of soil and the slope stability on the fill slope of forest road constructed in the regions which consist of igneous and metamorphic rock area. The results were summarized as follows. 1) Soil type by Unified Soil Classification System(USCS) was classified as SW in soil slope, GP in weathered rock slope, GP in soft rock slope for both types of parent rock, but gravelly soil slopes in igneous and metamorphic rock area were classified as SP and GW, respectively. 2) Dry unit weight was $1.34g/cm^2{\sim}1.59g/cm^2$, specific gravity 0.57~0.61, and void ratio 0.66~0.93 in the case of igneous rock area, a dry unit weight was $1.35g/cm^2{\sim}1.51g/cm^2$, specific gravity 2.67~2.77, and void ratio 0.78~1.01 in the case of metamorphic rock area. 3) The strength parameters such as internal friction angle(${\phi}$) and cohesion(c) were selected and tested for slope stability analysis. ${\phi}$ and c of soil in igneous rock area were within the range of $29.51^{\circ}{\sim}41.82^{\circ}$ and $0.03kg/cm^2{\sim}0.38kg/cm^2$, respectively, and $21.43^{\circ}{\sim}41.43^{\circ}$ and $0.05kg/cm^2{\sim}0.44kg/cm^2$ in metamorphic rock area, respectively. 4) Result of the slope stability analysis of forest road showed that, in the weathered rock slope of igneous rock and the weathered rock and soil slope of metamorphic rock area, the possibility of slope failure was high as safety factor was below 1.0.

  • PDF

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.

On the Nighttime Correction of CO2 Flux Measured by Eddy Covariance over Temperate Forests in Complex Terrain (복잡지형의 온대산림에서 에디 공분산으로 관측된 CO2 플럭스의 야간 자료 보정에 관하여)

  • Kang, Minseok;Kim, Joon;Kim, Hyun-Seok;Thakuri, Bindu Malla;Chun, Jung-Hwa
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.3
    • /
    • pp.233-245
    • /
    • 2014
  • Nighttime correction of $CO_2$ flux is one of the most important and challenging tasks in eddy covariance measurements over a complex mountainous terrain. In this study, we have scrutinized the quality and the credibility of the $CO_2$ flux datasets which were produced by employing three different methods of nighttime correction, i.e., (1) friction velocity ($u^*$) correction, (2) light response curve (LRC) correction, and (3) advection-based van Gorsel (VG) correction. The whole year datasets used in our analysis were collected at the two KoFlux tower sites (i.e., GDK deciduous forest site at the upper hill and GCK coniferous forest site at the lower hill) located in the valley of Gwangneung National Arboretum in central Korea. The resultant magnitudes and patterns of ecosystem respiration ($R_E$), gross primary productivity (GPP), and net ecosystem exchange (NEE) of $CO_2$ showed marked differences among the datasets produced with three different correction methods, which were also site-specific. The examination from micrometeorological and ecological perspectives suggests that the major cause of some inconsistency seems to be associated with the advection of $CO_2$ along the sloping terrain and the inappropriate selection of the correction data that might have been already affected by advective flows. The comparison with the results from other studies indicated that the overall characteristics of the corrected $CO_2$ fluxes at GDK and GCK (except those with LRC correction) were well within the ranges reported in the literature for various ecosystems in East Asia in similar latitudes. However, our study also implies that there will be always a room for further improvement in the present datasets. Therefore, caution must be exercised for the data users in order to properly use the updated version of datasets through transparent, open and participatory communication with data producers.

A Study on the Administration for the Han River Water Quality Control (漢江 水質保全 行政에 관한 硏究)

  • Kim, Kwang Hyop
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.2
    • /
    • pp.9-40
    • /
    • 1984
  • This thesis purports to overview the diverse administrative and organizational factors and plannings developed by the government organizations, municipal or otherwise, to tackle the Han River water pollution issues in the past years. This thesis also looks into the ever-worsening Han River water pollution problems, in particular, in terms of the various government plans ostensibly designed to reduce the pollution level but with little success. Also dealt with are the efficiencies with which the laws and decrees on water pollution the administrative organizations put to use in the prosecution of the diverse antiwater pollution projects involving the Han River basin. From the early 1960's up to the 1970's the government had concentrated on the growth-oriented economic policy with the result that little attention had been paid to the water pollution and other environmental issues that are bound to arise from the massive economic growth. Belatedly, the five-year Hah River Development Project was initiated in 1982 with emphasis on reducing the water pollution level at Hah River to the minimum. The following are the gists of the thesis and recommendations for the future antiwater pollution plans by the administrative organizations: 1. Documents to date indicate that the irrigation projects along the Han River area had been the main focus of attention during the Yi Dynasty and under the Japanese rule of the country. 2. Despite that the water pollution issue became the subject of many debates among the academic and research institutions in the 1960's and in the 1970's, the administrative organizations in charge of the Han River water quality control failed to come up with a concrete plan for the river's water quality control. 3. Nevertheless, the water pollution of the Han River area in fact began in the 1950's, with the unprecedented concentration into Seoul of population and the industrial facilities on a larger scale, in particular, enforced by the government's strong growthoriented policy in its Economic Development plans in the 1960's. 4. Starting in the 1960's, the Han River water pollution level dramatically increased, but the government was reluctant to promulgate or put into effect strong measures to curb the many factors contributing to the river water pollution, thus worsening the environmental issues along the Han River basin. 5. The environmental protection law and other laws and decrees relating to the antiwater and air pollution issues that were subsequently put into effect underwent so many changes that efficient anti-water pollution policies could not be effected for the Han River basin. The frequent organizational reshuffle within the administrative units concerned with environmental problems has resulted in the undue waste in personnel management and finance. 6. The administration on the environmental protection could not be efficiently carried out due to the organizational overlapping. Under the existing law, frequent organizational frictions and inefficiency are bound to occur among the central government offices themselves, as well as between the central government and the Seoul city administration, and among the city's administrative offices over the conservation of the Han River basin and over the river's anti-water pollution issue. 7. In the planning and prosecution of the Han River project, political influences from the president down to the lower-level politicious appear to have been involved. These political influences in the past had certainly had negative influence on the project, nevertheless, it appears that in the recent years, these political influences are not all that negative in view of the fact that they serve as a positive contributing factor in developing a better water quality control project along the Han River basin. The following are a few recommendations based on the data from the thesis: First, officials in charge of the Han River water quality control should pay attention to a careful screening of the opinions and recommendations from the academic circles and from the public should be made so that the government could better grasp the core issues in the environmental problems that require preventive and other necessary measures. Second, vigorous redistribution policies of population and industrial facilities away from the Seoul area should be pursued. Third, the government should refrain from revising or revamping too frequently the laws and decrees on the anti-water pollution, which is feared to cause undue inconveniences in the environmental administration. Fourth, a large-scale streamlining should be made to the existing administrative organization in an effort to do away with the inter- and intra-organizational friction. It is recommended that a secretariat for the Hah River basis conservation be established. Fifth, High-level administrative officials, with a thorough knowledge and vision on the Han River water quality control, should be prepared to better deal with the budgeting and personnel management for the Han River water pollution control not only at the control government, but also at the Seoul city municipal government levels. Environmental issues should be kept distinct from political issues. Environmental issues should not serve as a window-dressing for sheer political purposes. Sixth, the Hah River proiect should also include, along with the main Han River basin, those areas covering North Han River, South Han River, and the tributaries to the main river basin. The 'Han River Basin Water Quality Control Board' should be established immediately as a means of strengthening the current Han River basin water quality control policy. Seventh, in drawing up the Han River proiect, the administrative officials should be aware that Han River basin is a life line for those people in the region, providing them with not only a sheer physical space, but with a psychological living space for their everyday life.

  • PDF

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

A Spatial Statistical Approach to Migration Studies: Exploring the Spatial Heterogeneity in Place-Specific Distance Parameters (인구이동 연구에 대한 공간통계학적 접근: 장소특수적 거리 패러미터의 추출과 공간적 패턴 분석)

  • Lee, Sang-Il
    • Journal of the Korean association of regional geographers
    • /
    • v.7 no.3
    • /
    • pp.107-120
    • /
    • 2001
  • This study is concerned with providing a reliable procedure of calibrating a set of places specific distance parameters and with applying it to U.S. inter-State migration flows between 1985 and 1900. It attempts to conform to recent advances in quantitative geography that are characterized by an integration of ESDA(exploratory spatial data analysis) and local statistics. ESDA aims to detect the spatial clustering and heterogeneity by visualizing and exploring spatial patterns. A local statistic is defined as a statistically processed value given to each location as opposed to a global statistic that only captures an average trend across a whole study region. Whereas a global distance parameter estimates an averaged level of the friction of distance, place-specific distance parameters calibrate spatially varying effects of distance. It is presented that a poisson regression with an adequately specified design matrix yields a set of either origin-or destination-specific distance parameters. A case study demonstrates that the proposed model is a reliable device of measuring a spatial dimension of migration, and that place-specific distance parameters are spatially heterogeneous as well as spatially clustered.

  • PDF