• 제목/요약/키워드: Fresh concrete

검색결과 665건 처리시간 0.029초

지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;박경순
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

Interaction of magnetic water and polypropylene fiber on fresh and hardened properties of concrete

  • Ansari, Mokhtar;Safiey, Amir
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.307-318
    • /
    • 2021
  • Utilizing fibers is an effective way to avoid the brittle behavior of the conventional concrete and can enhance its ductility. In particular, propylene fibers can improve concrete properties, including energy absorption, physical and mechanical properties, controlling shrinkage cracks. The increase of fiber density leads to an increase of the overlapping surface of the fiber of concrete and, in turn, a decrease of cracks developed in the concrete. However, the workability of fiber reinforced concrete tends to be lower than the conventional concrete owing mainly to the hairline thickness and excessive concentration of fibers. The low slump of concrete impedes the construction of reinforced concrete members. In this research, we study if the utilization of magnetic water can alleviate the workability issue of young fiber reinforced concrete. To this end, the compressive and flexural strength of four types of concrete (conventional concrete, fiber reinforced concrete, magnetic concrete, magnetic fiber-reinforced concrete) is studied and compared at three different ages of 7, 14, and 28 days. In order to study the influence of the fiber density and length, a study on specimens with three different fiber density (1, 2, 5 kg of fiber in each cubic meter of concrete) and fiber length (6, 12, 18 mm) is undertaken. The result shows the magnetic fiber concrete can result in an increase of the flexural and compressive strength of concrete at higher ages.

Characterization of Recycled Coarse Aggregate (RCA) via a Surface Coating Method

  • Ryou, J.S.;Lee, Y.S.
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권2호
    • /
    • pp.165-172
    • /
    • 2014
  • Recycled coarse aggregate (RCA) made from waste concrete is not a suitable structural material as it has high absorption of cement mortar, which adheres on the aggregate surface and on the tiny cracks thereon. Therefore, when using RCA made from waste concrete, much water must be added with the concrete, and slump loss occurs when transporting. Hence, its workability is significantly worse than that of other materials. In this study, surface of RCA was coated with water-soluble polycarboxylate (PC) dispersant so that its characteristics improved. Each possibility was evaluated: whether its slump loss can be controlled, by measuring its workability based on the elapsed time; and whether it can be used as a structural material, by measuring its strength. Moreover, the carbonation due to cement mortar adhesion was measured through a carbonation test. As a result, RCA coated with PC dispersant was found to be better than crushed coarse aggregate and RCA when the physical properties of the fresh concrete and the mechanical, durability of the hardened concrete were tested.

재생잔골재 대체가 콘크리트 성능에 미치는 영향 (Effect of Substitution of Recycled Fine Aggregate on Concrete Performance.)

  • 정용일;양은익;정기철;김학모;최중철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.233-238
    • /
    • 2002
  • In this paper, the characteristics of fresh and hardened recycled concrete were experimentally compared to investigate the applicability of the recycled fine aggregates with the substitution ratio. Test results show that the workability of the recycled concrete decreases with the increment of substitution ratio of the recycled fine aggregates except for type-D case which has a lower absorption ratio. Also air content was increased with increasing substitution ratio. It was found that the compressive strength and elastic modulus of recycled concrete were decreased with increasing substitution ratio of the recycled fine aggregates. And, the superplasticizer was more effective on the workability recovery of the recycled concrete.

  • PDF

온도조건에 따른 고로슬래그 미분말을 사용한 고강도.고유동콘크리트의 특성에 관한 연구 (A Study on Properties of High Strength and High Flowing Concrete using Blast Furnace Slag according tn the Temperature Condition)

  • 김용로;장종호;길배수;백철;남재현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.339-344
    • /
    • 2001
  • This study is to investigate properties of high strength.high flowing concrete using blast-furnace slag in temperature conditions of 5, 10, 15 and $20^{\circ}C$. The result of this study can be summarized as follows. 1) The use of blast-furnace slag leads to decrease of air content and increase of fluidity in the fresh concrete. 2) The early compressive strength of high strength.high flowing concrete containing blast-furnace slag is lower than the case with portland cement only. 3) The compressive strength development of incorporating in the concrete is poor at low temperature below about $15^{\circ}C$.

  • PDF

미분의 효과적인 이용에 관한 연구 (Effective Use of Micro Fines)

  • 백신원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.73-78
    • /
    • 2001
  • Portland cement concrete is made with coarse aggregate, fine aggregate, portland cement, water and, in some cases, selected chemical admixtures such as air-entraining agents, water reducer, superplasticizer, and so on, and mineral admixtures such as fly ash, silica fume, slags, etc. Typically, in the concrete, the coarse aggregate and fine aggregate will occupy approximately 80 percent of the total volume of the final mix. Therefore, the coarse and fine aggregates affect to the properties of the portland cement concrete. As the natural sands are drained, it is necessary and economical to utilize crushed sands(manufactured fine aggregate). It is reported that crushed sands differ from natural sands in gradation, particle shape and texture, and the micro fines in the crushed sands affect to the quality of the portland cement concrete. Therefore, the purpose of this paper is to investigate the characteristics of fresh and hardened concrete with high content of micro fines. This study provides firm data for the use of crushed sands with higher micro fines.

  • PDF

폐유리를 혼입한 강섬유보강 콘크리트의 물리ㆍ역학적 특성에 관한 실험적 연구 (An Experimental Study on Physical and Mechanical Properties of Steel Fiber Reinforced Concrete Containing Waste Glass)

  • 박승범;이봉춘;조광연;이택우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.903-908
    • /
    • 2002
  • The production of waste glasses has been increased with the development of industry. The utilization of waste glass for concrete can cause the concrete to be cracked and to be weakened due to an expansion by alkali-silica reaction(ASR). When used the fibers with waste glass, there is an effect on reduction of expansion and strength loss due to ASR between the alkali in the cement paste and the silica in the waste glass. In this study, we conducted basic experimental research to analyze the possibilities of recycling of amber waste glass as fine aggregates for steel fiber reinforced concrete. Test results of fresh concrete. slump is decreased because grain shape is angular and air content is increased due to involving small size particles so much in waste glasses. Also. tensile and flexural strengths increased as the content of steel fibers increased. In conclusion, the content of waste glass below 40% is reasonable and usage of pertinent admixture is necessary to obtain workability or air content.

  • PDF

건식제조법에 의해 생산된 고품질 재생잔골재의 품질 및 재생콘크리트의 성상에 관한 연구 (A Study on the Qualities of Recycled Fine Aggregate and Properties of Recycled Concrete Producted by the Drying Manufacturing Method)

  • 장종호;이동혁;문형재;나철성;주지현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.364-367
    • /
    • 2004
  • The purpose of this study is to investigate quality of recycled fine aggregate manufactured by drying manufacturing system which is the manufacture method of high quality recycled fine aggregate, and to analyze on the fresh, hardened and durability properties of recycled concrete using it. Therefore it is to present the fundamental data for structural application of recycled concrete. The results of this study are as follows; Quality of recycled fine aggregate by drying manufacturing system is improved, and compressive and tensile strength of recycled concrete using high quality recycled fine aggregate are similar to those of normal concrete. But, durability such as carbonation, salt damage and dry shrinkage show decreased somewhat.

  • PDF

플라이애쉬 사용에 따른 콘크리트 품질변화에 관한 실험적 연구 (An experimental study on quality change of concrete according to fly ash using)

  • 박일용;백민수;손종규;최수;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.147-152
    • /
    • 1999
  • The purpose of this study is to offer foundmental information of fly ash concrete for field application. Through before study of fly ash concrete, various properties were checked. but when fly ash was added In concrete, entrained air quantity was decreased as fly ash substitution is increased in fresh concrete. so entrained air(below AE) quantity and a kind of AE according to fly ash substitution was tested basic properties. Also water-reducing efficiency was tested. And hydration heat according to fly ash substitution was tested by KR-100. As result of test, according to fly ash substitution increase, entrained air quantity is increase for target entrained air quantity, water-reducing efficiency and hydration heat are positive.

  • PDF

수중불분리콘크리트의 부착강도특성에 관한 연구 (A Study on the Bond Strength Properties of Antiwashout Underwater Concrete)

  • 김기동;윤재범;이상명;김명식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.153-159
    • /
    • 1999
  • The objective of this study was to investigate the bond strength properties of antiwashout underwater concrete. The fine aggregate(river sand, blended sand (river sand : sea sand = 1 : 1), condition of cast and cure(sea water, fresh water), and compressive strength of proportion(210kgf/$\textrm{cm}^2$ ~ 330kgf/$\textrm{cm}^2$) were chosen as the experimental parameters. The experimental results show that the underwater segregation resistance was increased, but flowability (slump flow) and air contents were decreased as the compressive strength of proportion increased. Bond strength of antiwashout underwater concrete was similar to plain concrete. From this study, rational analytic formula for the modulus of rupture and bond stress are to be from compressive strength of concrete.

  • PDF