• Title/Summary/Keyword: Frequency-Tuning

Search Result 694, Processing Time 0.029 seconds

Self-Oscillating Switching Technique for Current Source Parallel Resonant Induction Heating Systems

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This paper presents resonant inverter tuning for current source parallel resonant induction heating systems based on a new self oscillating switching technique. The phase error is suppressed in a wide range of operating frequencies in comparison with Phase Locked Loop (PLL) techniques. The proposed switching method has the capability of tuning under fast changes in the resonant frequency. According to this switching method, a multi-frequency induction heating (IH) system is proposed by using a single inverter. In comparison with multi-level inverter based IH systems, the advantages of this technique are its simple structure, better transients and wide range of operating frequencies. A laboratory prototype was built with an operating frequency of 35 kHz to 55 kHz and 300 W of output power. The performance of the IH system shows the validity of the new switching technique.

Development of IDS Program for Tuning Power System Controllers (전력시스템 제어기 튜닝을 위한 IDS 프로그램 개발)

  • Kim, D.J.;Kim, J.S.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.38-40
    • /
    • 2003
  • This paper describes the integrated dynamic stability(IDS) program for tuning the power system controllers, such as PSS, AVR and so on. IDS consists of three modules; power flow module, PWRLF, to calculate large scale power system load flow solutions, IDS/PSS module to calculate eigenvalues and frequency response in the range of frequency from 0.2Hz to 2Hz, and IDS/NEA module to calculate eigenvalues in the range of frequency from 5.0Hz to 55Hz. In addition, IDS provides graphic user interface(GUI) in order to let the user handle and analyze the input data and the results of calculation with convenience.

  • PDF

Revisiting the "T" in TMD

  • Strobel, Kurt;Salcedo, Victor
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.2
    • /
    • pp.109-116
    • /
    • 2021
  • This paper explores the meaning and importance of tuning amongst other Tuned Mass Damper (TMD) parameters and describes processes to help ensure that an as-built TMD is properly tuned to the as-built high-rise building. A summary of key TMD components and TMD implementations will be presented as an introduction and review. Next, it will be shown that tuning is a means for optimizing TMD performance. A process using modal characterization tests during tower construction to estimate natural frequencies of the completed tower will be described. Finally, the use of a Frequency Response Function (FRF) as a means for verifying the frequency of a TMD will be proposed.

Optimum parameters and performance of tuned mass damper-inerter for base-isolated structures

  • Jangid, Radhey Shyam
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.549-560
    • /
    • 2022
  • The optimum damping and tuning frequency ratio of the tuned mass damper-inerter (TMDI) for the base-isolated structure is obtained using the numerical searching technique under stationary white-noise and filtered white-noise earthquake excitation. The minimization of the isolated structure's mean-square relative displacement and absolute acceleration, as well as the maximization of the energy dissipation index, were chosen as the criteria for optimality. Using a curve-fitting technique, explicit formulae for TMDI damping and tuning frequency for white-noise excitation are then derived. The proposed empirical expressions for TMDI parameters are found to have a negligible error, making them useful for the effective design of base-isolated structures. The effectiveness of TMDI and its optimum parameters are influenced by the soil condition and isolation frequency, according to the comparison made of the optimized parameters and response with different soil profiles. The effectiveness of an optimally designed TMDI in controlling the displacement and acceleration response of the flexible isolated structure under real and pulse-type earthquakes is also observed and found to be increased as the inertance mass ratio increases.

AN ANALYSIS OF EMBEDDING IMPEDANCE FOR Q-BAND WAVEGUIDE GUNN OSCILLATOR WITH RESONANCE POST (공진 포스트 구조를 갖는 Q-band 도파관형 건 발진기의 임베딩 임피던스 해석)

  • 김현주;한석태;김태성;김광동;이창훈;정문희;김용기
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.119-128
    • /
    • 2001
  • The oscillation frequency tuning range of waveguide Gunn oscillator and its stability depend sensitively on the dimensions of the resonator. Therefore the embedding impedances with the various dimensions of the resonator for Q-band (33 ∼ 50 GHz) Gunn oscillator are calculated by using HFSS (High Frequency Structure Simulator). In this paper the comparisons between theoretical results of embedding impedances as a function of frequency and that of experimental results are described. And the oscillation frequency range could be predicted by using the theoretical evaluation methods which were proposed in this paper It shows that post size has an effect on the frequency tuning characteristics of Gunn oscillator.

  • PDF

A Numerical Study on Acoustic Behavior in Combustion Chamber with Acoustic Cavity (음향공이 장착된 로켓엔진 연소실의 음향장 해석)

  • Sohn, Chae-Hoon;Kim, Young-Mog
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.28-37
    • /
    • 2002
  • Acoustic behavior in combustion chamber with acoustoc cavity is numerically investigated by adopting linear acoustic analysis. Helmholtz-type resonator is employed as a cavity model to suppress acoustic instability passively. The tuning frequency of acoustic cavity is adjusted by varying the sound speed in acoustic cavity. Through harmonic analysis, acoustic pressure responses of chamber to acoustic oscillating excitation are shown and the resonant acoustic modes are identified. Acoustic damping effect of acoustic cavity is quantified by damping factor. As the tuning frequency approaches the target frequency of the resonant mode to be suppressed, mode split from the original resonant mode to lower and upper modes appears and thereby damping effect is degraded significantly. Considering mode split and damping effect as a function of tuning frequency, it is desirable to make acoustic cavity tuned to maximum frequency of those of the possible splitted upper modes.

A Design of Wide-Range Digitally Controlled Oscillator with an Active Inductor (능동 인덕터를 이용한 광대역 디지털 제어 발진기의 설계)

  • Pu, Young-Gun;Park, An-Soo;Park, Hyung-Gu;Park, Joon-Sung;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.3
    • /
    • pp.34-41
    • /
    • 2011
  • This paper presents a wide tuning range, fine-resolution DCO (Digitally Controlled Oscillator) with an active inductor. In order to control the frequency of the DCO, the transconductance of the active inductor is tuned digitally. In addition, the DCO gain needs to be calibrated digitally to compensate for gain variations. To cover the wide tuning range, an automatic three-step coarse tuning scheme is proposed. The DCO total frequency tuning range is 1.4 GHz (2.1 GHz to 3.5 GHz), it is 58 % at 2.4 GHz. An effective frequency resolution is 0.14 kHz/LSB. The proposed DCO is implemented in 0.13 ${\mu}m$ CMOS process. The total power consumption is 6.6 mW from a 1.2 V supply voltage. The phase noise of the DCO output at 2.4 GHz is -120.67 dBc/Hz at 1 MHz offset.

Design of the Electromagnetically Coupled Broadband Microstrip Antennas with Radial Tuning Stub (방사형 동조 스터브를 갖는 전자기결합 광대역 마이크로스트립 안테나의 설계)

  • 김정렬;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.1
    • /
    • pp.26-35
    • /
    • 1996
  • In this paper, characteristics of the electromagnetically coupled broadband microstrip antennas are analyzed by the Finite Difference Time Domain (FDTD) method, and antenna para- meters are optimized to get maximum bnadwidth. By using short radial tuning stub in microstrip feedline, electromagnetically coupled microstrip antenna shows broadband ($\simeq$13%) characteristics, and the characteristics are varied as a function of radius, radial angle, and position of the radial tuning stub. Operating frequency, return loss, VSWR and input impedance are calculated by Fourier transforming the time domain results. After optimization of the parameters, maximum bandwidth of the radial stub tuning microstrip antenna is about 15% and the ripple char- acteristic of the VSWR is better than the rectangular tuning stub microstrip antenna.

  • PDF

A Study on Varactor Tuning Gunn Oscillator for X Band (Varactor 튜닝 X 밴드 Gunn 발진기에 관한 연구)

  • 박한규;천장호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.5
    • /
    • pp.39-45
    • /
    • 1978
  • This paper described on the varactor tuning Gunn oscillator for X band. Analyzed the coplanar 2 post case using the dyadic Green's function then derived the obstacle network for the incident TE10 mode. For the electronical tuning, used the tuning varactor diode which has a high speed dynamic response characteristic and high Q. Oscillation frequency, switching mode, and stable oscillation point were calculated by the computer simulation. In the expriments, switching mode was occurred at 18 mm, 32.5 mm of the short tcircuit position, respectively. The general characteristics of the varactor tuning Gunn oscillator were abruptly changed by the moving of the short circuit and the variation of the bias voltage.

  • PDF

Development of ETMD for Improving TMD Control Performance (TMD 제어성능 개선을 위한 ETMD 개발)

  • Jeon, Seung gon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.157-164
    • /
    • 2022
  • The TMD has a simpler structure than other vibration control devices and shows excellent control performance for the standardized vibration occurring in the structure. However, when the vibration cycle of the structure coincides with the vibration cycle of the TMD due to the sudden external loads, the off-tuning occurs, which threatens the structure while increasing the vibration width of the TMD. Therefore, Electromagnetic Tuned Mass Damper (ETMD) was developed as a semi-active TMD that prevents off-tuning while exhibiting excellent control performance like TMD. To verify the control performance of the developed ETMD, the bending behavior control performance evaluation experiment using a simple beam bridge was performed. The experimental method compared the mutual control power by experimenting with the existing TMD method and the developed ETMD under nine excitation frequency conditions. As a result, it was confirmed that the control effect of ETMD was about 4.85% higher than that of TMD at 3.02Hz, which generates the maximum displacement in the simple beam bridge. Also, the off-tuning occurred in some excitation conditions when using TMD, although the off-tuning did not occur when using ETMD. Therefore, the excellent control performance of the ETMD developed in this study was verified.