• Title/Summary/Keyword: Frequency weighting

Search Result 326, Processing Time 0.029 seconds

A Study on Adequacy of Pipe Deterioration Evaluation Methods using the Endoscope of Water Distribution Pipe (배수관 내시경 조사를 통한 간접적인 관 노후도 평가방법의 적정성 연구)

  • Choi, Tae Ho;Kang, Sin Jae;Choi, Jae Ho;Koo, Ja Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.669-683
    • /
    • 2012
  • The water supply pipes are buried across wide range of areas, so it is hard to spot them using excavation and takes a large amount of expense. Thus, there is a high risk for direct research and application, accompanying many difficulties in implementation of them. Therefore, it is more economical and convenient to use indirect evaluation variables than direct evaluation of the buried pipes in assessing the degree of pipe deterioration. To assess the degree of pipe deterioration using the indirect evaluation variables, it should be done first to identify how and to what extent they affect the degree of deterioration. This study measured the evaluation variables for pipe deterioration using the pipe endoscope and analyzed the measurement results and the degree of impact on the pipes. In addition, this study attempted to evaluate the adequateness of the pipe deterioration evaluation using the indirect variables based on the analysis results. The evaluation variables measured through the pipe endoscope were the thickness of sediments, size of scale, degree of desquamation and condition of connections. For the indirect evaluation variables, the data such as the property data from GIS pipe network map as well as the material, diameter, age and pipe lining material of the pipe, road type, leakage frequency, average water velocity and water pressure using the leakage repair records was collected. Using the collected data, this study comparatively analyzed the indirect evaluation variables for the degree of pipe deterioration and the results from the pipe endoscope to choose appropriate variables for pipe deterioration evaluation and calculated the weights of the indirect variables on the degree of deterioration. The results showed that the order of the impact of indirect variables on deterioration was pipe age > pipe lining material > road type > leakage frequency > average water velocity with their weights of 0.45, 0.20, 0.15, 0.10, and 0.10, respectively. Conclusively, the results suggest that the measures of sediment thickness, scale size, degree of desquamation and condition of connections are appropriate for the evaluation of pipe deterioration and sufficient for the analysis of the impact of the indirect variables on deterioration.

ESD(Exponential Standard Deviation) Band centered at Exponential Moving Average (지수이동평균을 중심으로 하는 ESD밴드)

  • Lee, Jungyoun;Hwang, Sunmyung
    • Journal of Intelligence and Information Systems
    • /
    • v.22 no.2
    • /
    • pp.115-125
    • /
    • 2016
  • The Bollinger Band indicating the current price position in the recent price action range is obtained by adding/substracting the simple standard deviation (SSD) to/from the simple moving average (SMA). In this paper, we first compare the characteristics of the SMA and the exponential moving average (EMA) in the operator's point of view. A basic equation is obtained between the interval length N of the SMA operator and the weighting factor ${\rho}$ of the EMA operator, that makes the centers of the 1st order momentums of each operator impulse respoinse identical. For equivalent N and ${\rho}$, frequency response examples are obtained and compared by using the discrete time Fourier transform. Based on observation that the SMA operator reacts more excessively than the EMA operator, we propose a novel exponential standard deviation (ESD) band centered at the EMA and derive an auto recursive formula for the proposed ESD band. Practical examples for the ESD band show that it has a smoother bound on the price action range than the Bollinger Band. Comparisons are also made for the gap corrected chart to show the advantageous feature of the ESD band even in the case of gap occurrence. Trading techniques developed for the Bollinger Band can be straight forwardly applied to those for the ESD band.

The basic experiments for the fabrication of the SPUDT type Inter using the SFIT type filter (SFIT형태를 이용한 SPUDT형 필터제작에 관한 기초실험)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1916-1923
    • /
    • 2007
  • We have studied to obtain the SAW filter for the passband was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and thin we performed computer-simulated by simulator. We cm fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift of the SAW filter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000\;{\AA}$ and $3.6{\mu}m$ respectively. And we have employed that the distances from the hot electrode to the reflector are $2.0{\mu}m$, $2.4{\mu}m$ and the distance from the hot electrode to the ground is $1.5{\mu}m$ respectively. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7,8MHz. And we could obtain that return loss is less then -18dB, ripple characteristics is probably 3dB and triple transit echo is less then -25dB after when we have matched impedance.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

Spatio-Temporal Variability of Temperature and Precipitation in Seoul

  • Choi, Hyun-Ah;Lee, Woo-Kyun;Kim, So-Ra;Kwak, Han-Bin
    • Spatial Information Research
    • /
    • v.16 no.4
    • /
    • pp.467-478
    • /
    • 2008
  • This study analyzes the spatial and temporal variability of temperature ($^{\circ}C$) and precipitation (mm) in Seoul, Korea. The temperature and precipitation data were measured at 31 automatic weather stations (AWSs) in Seoul for 10 years from 1997 to 2006. In this study, inverse distance squared weighting (IDSW) was applied to interpolate the non-measured spaces. To estimate the temperature and precipitation variability, the mean values and frequencies of hot and cold days were examined. The maximum and minimum temperatures were $32.80^{\circ}C$ in 1999 and $-19.94^{\circ}C$ in 2001, respectively. The year 2006 showed the highest frequency of hot temperatures with 79 hot days, closely followed by 2004 and 2005. The coldest year was in 2001 with 105 cold days. The annual mean temperature and precipitation increased by about $1^{\circ}C$ and 483mm during the 10-year period, respectively. The temperature variability differed between high-elevation forested areas and low-elevation residential areas. However, the precipitation variability showed little relation with the topography and land use patterns.

  • PDF

Impedance-matching Method Improving the Performance of the SAW Filter (탄성표면파 필터의 성능 개선을 위한 임피던스 정합의 해석적 방법)

  • 이영진;이승희;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.69-75
    • /
    • 2001
  • In this paper, a fast and easy impedance matching method, which could give the impedance matching component for the general 1 or 2-port network was introduced. First, the entire network structure was defined which consists of the network part to be matched and the impedance matching part composed of inductors and capacitors. Next, the transmission matrix and input and output impedances of the entire network from the terminal impedance conditions were calculated, then the exact solutions for the matching components were obtained. To verify the efficiency of this method, this method was applied to the CDMA If band withdrawal weighted SAW transversal filter, and investigated the effects of the impedance matching before and after, through the simulation and experiment. As the result, the performance of a fractional bandwidth of 1.2%, insertion loss of 29 dB, and VSWR of 80 have improved to a factional bandwidth of 1.8%, insertion loss of 9 dB, VSWR of 3 at 85.38 MHz center frequency. The result shows that this impedance matching method could be used in the SAW devices and other types of 1 or 2-port network.

  • PDF

Appropriate Size and Dish Combination of Nutritional-Balanced Lunch Boxes Delivered to Children Under the Government-Funded Meal Service Program in Korea (영양적으로 균형 있는 아동급식사업용 도시락의 적정한 용기 크기 및 음식 구성)

  • Asano, Kana;Yoon, Ji-Hyun;Yoon, Bo-Rham
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.5
    • /
    • pp.565-575
    • /
    • 2009
  • The purpose of this study was to propose the appropriate sizes and dish combination for nutritional-balanced lunch boxes delivered to children under the government-funded meal service program in Korea. The study was based on the 3 : 1 : 2 Meal Box Magic, a nutrition education method developed in Japan. A total of 290 lunch menus, comprising of 10 day menus from 29 organizations having delivered lunch boxes to children during summer vacation of 2008, were analyzed and used as the base data for lunch box combination. Dishes of the menus were classified into 6 groups: Rice group, Protein side dish group (including meat, fish, egg, and bean dishes), Vegetable side dish group, Kimchi group (including kimchi and jangajji), Soup stew group, and the other group. Nutrient analysis was conducted for 100 ml of these dishes by CAN Pro 3.0 utilizing volume and weight conversion data used for analysis of the Korea Health and Nutrition Examination Survey and those from the Nutrient Composition of Food for Consumers. All the possible combinations of 5 dishes, comprising of 3 dishes from Rice group, Protein side dish group, and Kimchi group, respectively, and 2 dishes from Vegetable side dish group, were made using the frequently served dishes from the respective dish group. Nutrient analysis of each combination was conducted based on the assumption that a lunch box was 600 ml and filled up to 80% by dishes using the volume ratio of 3 : 1 : 1.5 : 0.5 for Rice group : Protein side dish group : Vegetable side dish group : Kimchi group. The mean and standard deviation of energy and nutrients of all combinations calculated by weighting the serving frequency of each dish selected for the combinations were $621\pm81$ kcal for Energy, $22.1\pm5.0$ g for Protein, $120\pm45$ mg for Calcium, $4.1\pm1.1$ mg for Iron, $201\pm130\;{\mu}g$ RE for Vitamin A, $0.34\pm0.10$ mg for Thiamin, $0.27\pm0.10$ mg for Riboflavin, and $24.3\pm9.6$ mg for Vitamin C. The energy percentages from Carbohydrate, Protein and Fat were 66%, 14% and 20%. The analysis results met the nutrition standard of lunch boxes for male elementary students in grades 4 through 6 under the government-funded meal service program regarding calories, nutrients except calcium and riboflavin, and macronutrient distribution ranges. Accordingly appropriate box sizes were suggested for different age and sex groups to meet the respective nutrition standards. In addition, milk or dairy products were suggested to accompany lunch boxes to supplement calcium and riboflavin intake. The method of selecting box sizes and making dish combination suggested in this study could be useful for the organizations preparing lunch boxes under the government-funded children's meal service program where nutrition professionals are not available.

Turbo FLASH NRI Using Optimized Flip Angle Pattern: Application to Inversion-Recovery T1-Weighted Imaging (최적화된 Flip Angle Pattern을 사용한 Turbo FLASH MRI: Inversion-Recovery T1-Weighted Imaging에의 응용)

  • Oh, C.H.;Choi, H.J.;Yang, Y.J.;Lee, D.R.;Ryu, Y.C.;Hyun, J.H.;Kim, S.R.;Yi, Y.;Jung, K.J.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.55-56
    • /
    • 1998
  • The 3-D Fast Gradient Echo (Turbo FLASH, Turbo Fast Low Angle Shot) sequence is optimized to achieve a good T1 contrast using variable excitation flip angles. In Turbo FLASH sequence, depending on the contrast preparation scheme, various types of image contrast can be established. While proton density contrast is obtained when using a short repetition time with a short echo time and small flip angles, T1 or T2 weighting can be obtained with proper contrast preparation sequences applied before the above proton density Turbo FLASH sequence. To maximize the contrast to noise ratio while retaining a sharp impulse response (smooth frequency domain response), the excitation flip-angle pattern is optimized through simulation and experiments. The TI (the delay after the preparation sequence which is a 180 degree inversion RF pulse in the IR T1 weighted imaging case), TD (the delay time between the Turbo FLASH sequence and the next preparation), and TR are also optimized fur the best image quality. The proposed 3-D Turbo FLASH provides $1mm\times1mm\times1.5mm$ high resolution images within a reasonable 5-8 minutes of imaging time. The proposed imaging sequence has been implemented in a Medison's Magnum 1.0T system and verified through simulations as well as human volunteer imaging. The experimental results show the utility of the proposed method.

  • PDF

Interpretation of Subsurface Fracture Characteristics by Fracture Mapping and Geophysical Loggings (단열조사 및 물리검층을 통한 지표 하 단열특성 해석)

  • Chae, Byung-Gon;Lee, Dae-Ha;Kim, Yu-Sung;Hwang, Se-Ho;Kee, Weon-Seo;Kim, Won-Young;Lee, Seung-Gu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.1
    • /
    • pp.37-56
    • /
    • 2001
  • As a preliminary study to establish fracture network model in crystalline rocks, detail investigation on fracture characteristics were performed. Five fracture sets were determined on the basis of regional survey of geological structures and fractures on outcrops. Among the fracture sets, S1 set has the highest density and longest trace length of fractures which was identified on surface in the study area. S4 and S5 sets are composed of foliations and foliation parallel shear joints of gneisses, which are very important sets at the aspect of weighting of fracture length. For characterization of subsurface fractures, detail core logging was performed to identify fractures and fracture zones from five boreholes. Acoustic televiewer logging and borehole geophysical loggings produced images, orientations and geophysical properties of fractures which intersect with boreholes. According to the result of the investigations, subsurface fractures can be grouped as three preferred orientations(B1, B2 and B3), which correspond to S1, S2 and S4/S5 of surface fracture sets, respectively. Actually, B1 set is expected to be intensely developed at subsurface. However, it has low frequency of intersection with boreholes due to its parallel or sub-parallel direction to boreholes. According to the inference of conductive fractures, B1 and B3 sets have possibilities of water flow and their intersection lines are also thought to consist of important conduits of groundwater flow. In particular, faults which are parallel to foliations control major groundwater flow in the study area.

  • PDF