• Title/Summary/Keyword: Frequency value

Search Result 4,713, Processing Time 0.032 seconds

Contrast Sensitivity as a Function of Spatial Frequency for 12 Year Old Child-Eye (눈의 공간주파수와 대비 민감도 함수(CSF) 특성에 대한 연구)

  • Kim, Yong Geun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.63-68
    • /
    • 1999
  • It was made of a chart by new method to be measured the contrast sensitivity for a spatial frequency, and the mean luminance of a lattice frequency was made to three forms of 25, 50, 75% and let it to be ready a CS value from 0 to $10^3$. As a result of measuring of the CS value for a spatial frequency on a target of 12 year old students, CS value decreased of according to down the average luminance value and also the peak position shift to low spatial frequency. The low visioned person decreased the CS value in side of high frequency or in space of total frequency. By the lattice adaptation, a measured CS value was decreased in circumstance regions of adapted space frequency.

  • PDF

A Study on Rancidity of Edible Soybean Oil by Cooking Frequency in Mass Meal Services and Homes (단체급식소 및 가정에서 식용유의 사용실태와 산패도에 관한 조사 연구)

  • 서은숙;한소현;문범수
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.4
    • /
    • pp.213-220
    • /
    • 1994
  • Customary usage of oil at homes and rancidity of edible soybean oil by cooking frequency at homes and mass meal services were investigated. 80% of house wives bought the cooking oil by 1.8ι unit container and 70% of them read either the manufactured date or explanatory note for use. 85% of house wives kept oil in the storage case under sink or in the pantry chest, and 80% of oils were used once or twice and 20% used three times for cooking. Acid value(AV), iodine value(IV), peroxide value(POV), carbonyl value(CoV) and thiobarbituric acid value(TBAV) of fresh soybean oil were lower than standard level. In the rancidity by cooking frequency, the acid value, peroxide value, carbonyl value and thiobarbituric acid value increased significantly when oil was used once and iodine value decreased significantly when used once and twice at both mass meal services and homes. The level of the acid value, iodine value, carbonyl value and thiobarbituric acid value of oil used at mass meal services did not show significant difference from those of oil used at homes. But, the peroxide value of oil used thrice at mass meal services was significantly higher than those of homes.

  • PDF

A Simulation for the Natural Frequencies of Curved Pipes Containing Fluid Flow with Various Elbow Angles (시뮬레이션에 의한 유체 유동 파이프 계의 곡관부의 각도 변화에 따른 고유진동수 고찰)

  • 최명진;장승호
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.1
    • /
    • pp.63-65
    • /
    • 2001
  • To investigate the natural frequencies of curved piping systems with various elbow angles conveying flow fluid, a simulation is performed considering Initial tension due to the inside fluid. The system is analyzed by finite element method utilizing straight beam element. Elbow part is meshed using 4 elements, and the initial tension is considered by inserting equivalent terms into the stiffness matrix. Without considering the initial tension, the system becomes unstable, that is, the fundamental natural frequency approaches to zero value fast, as the flow velocity reaches critical value. With the initial tension terms, the system becomes stable where there is no abrupt decrease of the fundamental natural frequency. The change rate of the natural frequency with respect to the flow velocity reduces. As elbow angle increases, the system becomes stiffer, then around 150 degrees of the elbow angle the natural frequency has the largest value, the value decreases after the angle of the largest natural frequency. When angle is between 170 degrees and 179 degrees, the natural frequency is very sensitive. This means that small change of angle results in great change of natural frequency, which is expected to be utilized in the control of the natural frequency of the piping system conveying flow fluid.

  • PDF

Performance Evaluation of Advanced Frequency Estimation Technique using 765kV Modeling Data (765kV 모델링 데이터에 의한 개선된 주파수 추정기법의 성능 평가)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.253-257
    • /
    • 2010
  • The frequency is an important operation parameter for the control, protection, and stability of a power system. The frequency as a key index of power quality can be indicative of system abnormal conditions and disturbances. Due to the sudden change in generation and loads or faults in power system, the frequency is supposed to deviate from its nominal value. It is essential that the frequency must be maintained very close to its nominal frequency. An accurate monitoring of the power frequency is essential to optimal operation and prevention for wide area blackout. As most conventional frequency estimation schemes are based on DFT filter, it has been pointed out that the gain error could cause defects when the frequency is deviated from nominal value. This paper presents an advanced frequency estimation technique using gain compensation to improve the performance of DFT filter based techniques. To evaluate performance of the proposed algorithm, the 765kV T/L system in Korea is simulated by EMTP-RV software. The proposed technique can reduce the gain error caused when the power system frequency deviates from nominal value.

Image Global K-SVD Variational Denoising Method Based on Wavelet Transform

  • Chang Wang;Wen Zhang
    • Journal of Information Processing Systems
    • /
    • v.19 no.3
    • /
    • pp.275-288
    • /
    • 2023
  • Many image edge details are easily lost in the image denoising process, and the smooth image regions are prone to produce jagged. In this paper, we propose a wavelet-based image global k- singular value decomposition variational method to remove image noise. A layer of wavelet decomposition is applied to the noisy image first. Then, the image global k-singular value decomposition (IGK-SVD) method is used to remove the random noise of low-frequency components. Furthermore, a constructed variational denoising method (VDM) removes the random noise in the high-frequency component. Finally, the denoised image is obtained by wavelet reconstruction. The experimental results show that the proposed method's peak signal-to-noise ratio (PSNR) value is higher than other methods, and its structural similarity (SSIM) value is closer to one, indicating that the proposed method can effectively suppress image noise while retaining more image edge details. The denoised image has better denoising effects.

Study on Advanced Frequency Estimation Technique using Gain Compensation

  • Park, Chul-Won;Shin, Dong-Kwang;Kim, Chul-Hwan;Kim, Hak-Man;Kim, Yoon-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.439-446
    • /
    • 2011
  • Frequency is an important operating parameter for the protection, control, and stability of a power system. Thus, it must be maintained very close to its nominal frequency. Due to the sudden change in generation and loads or faults in a power system, however, frequency deviates from its nominal value. An accurate monitoring of the power frequency is essential for optimum operation and prevention of wide area blackout. Most conventional frequency estimation schemes are based on the DFT filter. In these schemes, the gain error could cause defects when the frequency deviates from the nominal value. We present an advanced frequency estimation technique using gain compensation to enhance the DFT filter-based technique. The proposed technique can reduce the gain error caused when the frequency deviates from the nominal value. Simulation studies are performed using both the data from EMTP-RV software and the user-defined arbitrary signals to demonstrate the effectiveness of the proposed algorithm. Results show that the proposed algorithm achieves good performance under both steady state tests and dynamic conditions.

The Childrens′Value Orientation and Preservation Behavior on Environment (아동의 환경에 대한 가치지향과 보전행동)

  • 황경혜
    • Korean Journal of Human Ecology
    • /
    • v.3 no.1
    • /
    • pp.40-50
    • /
    • 2000
  • The purpose of this study is to investigate the influential variables related to the value orientation and environmental preservation behavior. This study is also to provide data for environment education. The subjects were 538 children, in June. 1998, in Kwangju. The data obtained were analyzed by Pearson's correlation. Cronbach's u coefficient. multiple regression. and Path analysis. The major findings were as follows : 1) The influential variables for childrens'egoistic value orientation were grade level of children and education level of mother The influential variables for childrens'altruistic orientation were the frequency of contact for environmental information and age of mother. The influential variables for childrens'biospheric orientation were education level of mother and the frequency of contact for environmental information. 2) The influential variables for the childrens'behavior on the environmental preservation were the frequency of contact for environmental information. biospheric orientation. grade level of children and education level of mother.

  • PDF

Advanced Frequency Estimation Technique using Gain Compensation (이득 보상에 의한 개선된 주파수 추정 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • Frequency is an important operating parameter of a power system. Due to the sudden change in generation and loads or faults in power system, the frequency is supposed to deviate from its nominal value. It is essential that the frequency of a power system be maintained very close to its nominal frequency. And monitoring and an accurate estimation of the power frequency by timing synchronized signal provided by FDR is essential to optimum operation and prevention for wide area blackout. As most conventional frequency estimation schemes are based on DFT filter, it has been pointed out that the gain error by change in magnitude could cause the defects when the power frequency is deviated from nominal value. In this paper, an advanced frequency estimation scheme using gain compensation for fault disturbance recorders (FDR) is presented. The proposed scheme can reduce the gain error caused when the power frequency is deviated from nominal value. Various simulation using both the data from EMTP package and user's defined arbitrary signals are performed to demonstrate the effectiveness of the proposed scheme. The simulation results show that the proposed scheme can provide better accuracy and higher robustness to harmonics and noise under both steady state tests and dynamic conditions.

A Temperature Analysis Study of East Asia for Generation of Temperature Specification (온도규격 설정을 위한 동아시아 온도 분석연구)

  • 김인수;강치우
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.11-22
    • /
    • 2002
  • In this paper, a statistical meaning that the 1% frequency value which is used as a basis for the temperature specification generation for weapon systems is similar to $3{\sigma}$ frequency value of a year is presented, and the theoretical reference for temperature specification generation is made. The new method which extracts the 1% frequency value from general weather data, not depending on long term temperature hour data, is established, and the temperature analysis result of East Asia is also presented by using this method. On the basis of these result, operational temperature for the weapon systems to be used in the area of East Asia is recommended.

A Study on the Optimal Frequency for Precise Measurement of Fracture Velocity by Ultrasonic Fractography (초음파 Fractography에 의한 파괴속도의 첨밀측정을 위한 최적주파수 선정에 관한 연구)

  • Lee, B.S.;Han, E.K.;Song, C.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.154-160
    • /
    • 1993
  • A mothod to decide the optimal frequency for the fracture velocity measurement by ultrasonic fractography is presented. A theoretical formula to decide the optimal frequency for ultrasonic fractography testing is made and it is compared with experimental value. According to the formula the optimal frequency is shown to be depending on the attenuation coefficient and size(width) of the specimen. In the case of PMA specimen with ligament 43mm the theoretical value for the optimal frequency is about 260 KHz and it is good agreement with experimental value.

  • PDF