• 제목/요약/키워드: Frequency stability

검색결과 1,991건 처리시간 0.044초

Estimating Stability of MTDC Systems with Different Control Strategy

  • Nguyen, Thai-Thanh;Son, Ho-Ik;Kim, Hak-Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.443-451
    • /
    • 2015
  • The stability of a multi-terminal direct current (MTDC) system is often influenced by its control strategy. To improve the stability of the MTDC system, the control strategy of the MTDC system must be appropriately adopted. This paper deals with estimating stability of a MTDC system based on the line-commutated converter based high voltage direct current (LCC HVDC) system with an inverter with constant extinction angle (CEA) control or a rectifier with constant ignition angle (CIA) control. In order to evaluate effects of two control strategies on stability, a MTDC system is tested on two conditions: initialization and changing DC power transfer. In order to compare the stability effects of the MTDC system according to each control strategy, a mathematical MTDC model is analyzed in frequency domain and time domain. In addition, Bode stability criterion and transient response are carried out to estimate its stability.

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

3차원 ID-FDTD 알고리즘의 Stability Condition과 광대역 특성 분석 (Analysis of Stability Condition and Wideband Characteristics of 3D Isotropic Dispersion(ID)-FDTD Algorithm)

  • 김우태;고일석;육종관
    • 한국전자파학회논문지
    • /
    • 제22권4호
    • /
    • pp.407-415
    • /
    • 2011
  • 본 논문에서는 등방성(isotropic) 특성과 작은 분산 오차(low dispersion error)를 갖는 3차원 등방성 시간 영역 유한 차분법(ID-FDTD: Isotropic Dispersion Finite Difference Time Domain) 방법의 stability condition과 광대역 해석 특성에 대해 논의하였다. 3차원 ID-FDTD 방법은 기존의 Yee FDTD 방법의 비등방성 특성과 큰 분산 오차를 개선하기 위해 제안되었다. 기존 연구에서는 3차원 ID-FDTD 방법의 stability condition을 수치적으로 계산하였지만, 이에 대한 검증이 충분히 이뤄지지 않은 상태이다. 이에 본 논문에서는 단일 주파수와 광대역 주파수 신호를 입력원으로 한 모의 실험 환경에서 3차원 ID-FDTD 방법의 stability condition 검증을 수행하였다. 또한 광대역 특성에 대해 3차원 ID-FDTD 방법과 유사한 알고리즘들을 비교 분석해 해보았고, 마지막으로 3D ID-FDTD을 적용하여 대형 크기 구 모델에 대해 radar cross section(RCS) 해석을 수행함으로써, 실질적 해석을 통한 알고리즘 검증 및 분석을 마무리 하였다.

On-line 발전기 주파수응답시험 개발 및 적용에 관한 연구 (Study on Development & Implementation of Online Generator Frequency Response Test)

  • 오창수;곽월환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.48-49
    • /
    • 2006
  • Recently, Importance of Generator's Active/Reactive Power Control Capability is highly emphasized for prevention of Large Blackout. Especially, Generator's frequency Response Capability is important to the Power System Frequency Stability. This paper deals with the Development & Implementation of Each Generator Frequency Response Capability Test via the Injection of Artificial Frequency to the Online Generator. Actual On-line Generator's frequency Response Test was successfully implemented to 13 Generator having various fuel source.

  • PDF

족관절 근육에 인가한 전기 자극의 특성에 따른 자세안정성 평가 (Evaluation of Postural Stability according to characteristics of Electrical Stimulation on the ankle muscles)

  • 이선연;유미;김남균;김동욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.521-528
    • /
    • 2009
  • This study is about to evaluation of postural stability according to characteristics of electrical stimulation on the ankle muscles. We measured body sway(center of pressure, COP) when various parameters of electrical stimulation was applied to ankle muscles in stable and unstable posture. Subjects consisted of 10 young adults, and electrical stimulation was delivered on right and left of tibialis anterior and Achilles tendon. The body sway was measured during electrical stimulation of three duty cycle and frequencies in stable posture and three amplitudes of sensory threshold in unstable posture. Consequently, the COP Shift is higher during electrical stimulation of 1/30(duty ratio) and 100Hz(frequency) in stable posture. In unstable posture, 100% amplitude of sensory threshold induced postural stability. These findings are important for the rehabilitation system of postural stability and the use of electrical stimulation as somatosensory information.

파랑 중 실린더형 구조물의 동적 안정성에 대한 연구 (Study on Dynamic Stability of Cylindrical Structure in Waves)

  • 장민석;조효제;황재혁;김재희;이병성;박충환
    • 한국해양공학회지
    • /
    • 제31권3호
    • /
    • pp.196-201
    • /
    • 2017
  • A cylindrical structure has a very long period of heave and pitch motion response in ocean waves. To obtain the dynamic stability of a cylindrical structure, it is necessary to obtain the suitable metacentric height (GM). However, in a structure with sufficient metacentric height, Mathieu instability can occur if the natural frequency of the heave motion is double the natural frequency of the roll and pitch motion. This study carried out numerical calculations and experiments for vertical-axis wind turbines with cylindrical floaters, which had three different centers of gravity. In the regular wave experiment, the divergence of the structure motion without yaw was observed when the natural frequency of the heave motion was double the natural frequency of the roll and pitch motion. In the irregular wave experiment, the motion spectra of the structures with the different centers of gravity were compared, and one was very high when the natural frequency of the heave motion was double the natural frequency of the roll and pitch motion.

배플이 장착된 로켓 연소기의 선형 안정성 해석 (Linear Stability Analysis of a Baffled Rocket Combustor)

  • 이수용
    • 한국추진공학회지
    • /
    • 제22권3호
    • /
    • pp.46-52
    • /
    • 2018
  • 액체산소 및 탄화수소를 사용하는 연소기의 고주파 연소불안정을 해석하기 위해 단순모델로서 Crocco의 $n-{\tau}$ 시간지연 연소모델을 적용하고, 음향과 커플된 연소기 내 유동에 대해 선형해석을 수행하였다. 변수분리를 통해 편미분 포텐셜함수 식을 원통좌표계 미분방정식으로 만들고, 연소기의 접선방향 공진모드에 대한 고유 값을 계산하였다. 분사면 및 노즐입구를 경계조건으로 적용하여 미분식의 해를 구했다. 시스템의 안정성 판정을 위해 전달함수를 주파수 해석 하였으며, 관심 영역 주파수인 1T 모드 주변 주파수에서 시스템 게인 및 위상각으로 안정성 여유를 평가하였다. 또한 1T 모드 안정성 향상을 위해 배플 길이 및 형상에 대한 영향을 평가하였다.

135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석 (An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator)

  • 옥연호;이은웅;변일환;오석영
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.

Frequency response of film casting process

  • Hyun, Jae-Chun;Lee, Joo-Sung;Jung, Hyun-Wook
    • Korea-Australia Rheology Journal
    • /
    • 제15권2호
    • /
    • pp.91-96
    • /
    • 2003
  • The sensitivity of the product to the ongoing sinusoidal disturbances of the process has been investigated in the film casting of viscoelastic polymer fluids using frequency response analysis. As demonstrated for fiber spinning process (Jung et al., 2002; Devereux and Denn, 1994), this frequency response analysis is useful for examining the process sensitivity and the stability of extensional deformation processes including film casting. The results of the present study reveal that the amplification ratios or gains of the process/product variables such as the cross-sectional area at the take-up to disturbances exhibit resonant peaks along the frequency regime as expected for the systems having hyperbolic characteristics with spilt boundary conditions (Friedly, 1972). The effects on the sensitivity results of two important parameters of film casting, i.e., the fluid viscoelasticity and the aspect ratio of the casting equipment have been scrutinized. It turns out that depending on the extension thinning or thickening nature of the fluid, increasing viscoelasticity results in enlargement or reduction of the sensitivity, respectively. As regards the aspect ratio, it has been found that an optimum value exists making the system least sensitive. The present study also confirms that the frequency response method produces results that corroborate well those by other methods like linear stability Analysis and transient solutions response. (Iyengar and Co, 1996; Silagy et al., 1996; Lee and Hyun, 2001).

Thirty-two-tupling frequency millimeter-wave generation based on eight Mach-Zehnder modulators connected in parallel

  • Xinqiao Chen;Siyuan Dai;Zhihan Li;Wenyao Ba;Xu Chen
    • ETRI Journal
    • /
    • 제46권2호
    • /
    • pp.194-204
    • /
    • 2024
  • A new method is proposed to generate a 32-tupling frequency millimeter wave (MMW) with eight Mach-Zehnder modulators (MZMs) connected in parallel. Theoretical analyses and simulation experiments are conducted. The optical sideband suppression ratio (OSSR) of the obtained ±16th order optical sidebands are 61.54 dB and 61.42 dB, and the radio frequency spurious suppression ratios (RFSSRs) of the generated 32-tupling frequency MMW are 55.52 dB and 55.27 dB based on the theoretical analysis and simulation experiments, respectively; these outcomes verified the feasibility of the new method. The main parameters used to affect the stability of the generated signal are the modulation index and extinction ratio of MZM. Their effects on the OSSR and RFSSR of the generated signals are investigated when they deviate from their designed values. Compared with the other proposed methods for the generation of 32-tupling frequency MMW by MZM, our method has the best spectral purity and stability, and it is expected to have important MMW over fiber applications.