• Title/Summary/Keyword: Frequency response analysis(FRA)

Search Result 8, Processing Time 0.023 seconds

A high Efficient Solver for High-Frequency Response Analysis of MEMS Resonators (MEMS 공진기의 고주파 응답해석을 위한 고효율 해석기)

  • Ko, Jin-Hwan;Bai, Zhaojun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.467-472
    • /
    • 2007
  • A modern MEMS resonator is a micro-scale structure operated over a high frequency range. In order to predict its resonant behavior in a design process, High-frequency response analysis (Hi-FRA) is demanded. Algebraic substructuring (AS) is known as a fast numerical technique to construct an eigenspace for FR and frequency sweep (FS) algorithm efficiently solves the frequency response system projected on the eigenspace. However, the existing FS algorithm using AS is developed for low-FRA, say over the range 1Hz-2KHz. In this work, we extend the FS algorithm using AS for FRA over an arbitrary frequency range. Therefore, it can be efficiently applied to systems operated at a high frequency, say over the range 230MHz-250MHz. The success of the proposed method is demonstrated by Hi-FRA of a checkerboard resonator.

  • PDF

A fault prevention diagnostic of power transformer using Frequency Response Analysis (주파수 응답 분석(FRA)을 이용한 전력용 변압기 고장예방 진단)

  • Cho, Yun-Haeng;Lim, Tae-Young;Kim, Jong-Seon;Kim, Gi-Il;Ahn, Kwang-Won;Lim, Seong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.463-464
    • /
    • 2011
  • Currently, different kinds of diagnosis and inspection technologies are applied to prevent the internal mechanical transformation of transformers. For example, examination of internal Partial Discharge of transformer, analysis of transformer oil gas, and measurement Frequency Response Analyzer(FRA) are used to diagnose defect. Especially, diagnosis technique through Frequency Response Analyzer(FRA) has been used and developed from 1960, when it was first introduced, till now to become an important tool to examine presence of defect and to prove quality of machines for the most electric machine producers electric power company in the world. However, diagnosis through FRA is still in introduction level in Korea and the application method for FRA is not established yet. For that reason, study about the application of domestic electric installation according to the FRA is needed. It is expected that the study play an important part in the prevention of defect due to the internal transformation of transformer by introducing measurement theory, providing measurement method, and analyzing application cases.

  • PDF

Study on Failure Diagnosis of Power Transformer Using FRA

  • Sano, Takahiro;Miyagi, Katsunori
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.324-329
    • /
    • 2006
  • As the average usage period of transformers increases, it is becoming increasingly necessary to know the internal condition of transformers. It is therefore critically important to establish monitoring and diagnostic techniques that can perform transformer condition assessment. Frequency response analysis, generally known as FRA, is one of the technologies to diagnose transformers. Using case studies, this paper presents the effectiveness of FRA as measurements for detecting transformer failures. This paper introduces the fact that FRA waveforms have useful information about diagnosis of failure on core earths and winding shield, and that the condition outside transformers can affect frequency response characteristics.

Research on Assessment Method of Deterioration Condition for Power Transformer Using Sweep Frequency Response Analyzer (주파수응답분석기를 이용한 전력용 변압기 열화상태 평가방법 연구)

  • Gil, Hyoung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.30-35
    • /
    • 2013
  • This paper describes the assessment method of deterioration condition for a power transformer using SFRA. Frequency Response Analysis(FRA) is a method to evaluate the mechanical and geometrical integrity of the core and windings within a power transformer by measuring the electrical transfer functions over a wide frequency range. SFRA is sweep frequency response analyzer for power transformer winding diagnosis. The FRA is a comparative method, that evaluates the transformer condition by comparing the obtained set of FRA results to reference results on the same, or a similar, unit. FRA techniques were widely used and much more sensitive than the traditional and internationally accepted method of impedance measurements, but that work was required on standardization and interpretation. In order to analyze the deterioration condition for power transformer, overvoltage test and mechanical distortion test were carried out. The deterioration condition for power transformer was evaluated by SFRA. It is intended to present the elemental technology of assessment method for power transformer using SFRA.

Effects of the Insulation Quality on the Frequency Response of Power Transformers

  • Abeywickrama Nilanga;Ekanayake Chandima;Serdyuk Yuriy V.;Gubanski Stanislaw M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.534-542
    • /
    • 2006
  • This paper presents results of frequency domain spectroscopy (FDS) measurements on oil-impregnated pressboard insulation, their analyses and use of the data for modeling high frequency response (FRA) of transformers. The dielectric responses were measured in a broad frequency range, i.e. from 0.1 mHz to 1 MHz, on model samples containing different amount of moisture. The responses were parameterized with terms representing dc conductivity, low frequency dispersion and Cole-Cole polarization mechanisms and they were thereafter used to model the FRA response of a three-phase transformer.

Beating phenomena in spacecraft sine testing and an attempt to include the sine sweep rate effect in the test-prediction

  • Nali, Pietro;Bettacchioli, Alain
    • Advances in aircraft and spacecraft science
    • /
    • v.3 no.2
    • /
    • pp.197-209
    • /
    • 2016
  • The Spacecraft (S/C) numerical sine test-predictions are usually performed through Finite Element Method (FEM) Frequency Response Analysis (FRA), that is the hypothesis of steady-state responses to harmonic excitation to the S/C base is made. In the test practice, the responses are transient and may be significantly different from those predicted through FRA. One of the most significant causes of discrepancy between prediction and test consists in the beating phenomena. After a brief overview of the topic, the typical causes of beating are described in the first part of the paper. Subsequently, focus is made on the sine sweep rate effect, which often leads to have beatings after the resonance of weakly damped modes. In this work, the approach illustrated in the literature for calculating the sine sweep rate effect in the case of Single-Degree-Of-Freedom (SDOF) oscillators is extended to Multi-Degrees-Of-Freedom (MDOF) systems, with the aim of increasing the accuracy of the numerical sine test-predictions. Assumptions and limitations of the proposed methodology are detailed along the paper. Several assessments with test results are discussed and commented.

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

A Evaluation on the Effect of Vibration for the Application of PEMFC Stack to Unmanned Aircraft (고분자 전해질 연료전지 스택의 무인기 적용을 위한 진동 영향 평가)

  • KANG, JUN-YOUNG;OH, GUN-WOO;KIM, MIN-WOO;LEE, JUNG-WOON;LEE, SEUNG-KUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.587-595
    • /
    • 2018
  • Recently, research is being conducted to use a fuel cell as a power source of unmanned aircraft. However, safety standards about applying fuel cells to unmanned aircraft are insufficient. In this paper, to improve the safety of the fuel cells for unmanned aircraft is experimentally studied. For this reason, standards for safety of fuel cells were analyzed. And influence of vibration among the evaluation items related to the safety of the fuel cell for unmanned aircraft was discussed. In order to, at constant intervals, vibration was applied to the fuel cell, then the performance was measured, the measurement items were gas tightness, polarization curve, frequency response analysis (FRA). A total of 220 hours was experimented at 20 hour intervals. the result of vibration test, gas leakage rate was a maximum of -0.04826 kPa/min and Polarization curve reached a maximum of 1.0103 times of the initial value, the charge transfer resistance reached a maximum of 1.0104 times of the initial value. This research indicate that performance of fuel cell is affected by vibration and this study is expected to contribute to the safety of fuel cell for unmanned aircraft.