• Title/Summary/Keyword: Frequency range

Search Result 7,096, Processing Time 0.032 seconds

Effects of $Ca^{2+}-antagonists$ on the electrical activity of guinea-pig taenia coli (결장뉴 전기활동도에 대한 칼슘 길항제의 영향)

  • Kim, Ki-Whan;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 1985
  • The influences of $Ca^{2+}-antagonists$, verapamil and $Mn^{2+}$, upon the spontaneous electrical activity and contractions were studied in guinea-pig taenia coli. Spontaneous contractions were recorded with force transducer, and spike action potentials were measured extracellularly by use of suction electrode. All experiments were performed in tris-buffered Tyrode solution Which was aerated With 100% $O_2$ and kept at $35^{\circ}C$. The results obtained were as follows : 1) Verapamil suppressed the frequency and amplitude of spontaneous contractions dose dependently, and blocked completely mechanical responses at the concentration of 1 mg/1. 2) The frequency of bursts of spike discharge(bursts frequency) and the number of spikes in a burst(spikes frequency) were reduced in a dose·dependent manner within the concentration range of $10^{-5}$ to $10^{-3}g/l$, and bursts frequency was affected more readily at a low concentration of $10^{-5}g/l$ verapamil. 3) The verapamil_induced suppression of spontaneous contractions in the Tyrode solution containing 1 mM $Ca^{2+}$ was completely antagonized by the addition of extra $Ca^{2+}$ to the Tyrode solution $(2\;m\;MCa^{2+})$. 4) $Mn^{2+}$ suppressed the amplitude of spontaneous contractions, whereas $Mn^{2+}$ accelerated the frequency dose-dependently within the range of low concentrations$(10^{-7}\;to\;10^{-4}\;M\;Mn^{2+})$. 5) The bursts frequency determining frequency of spontaneous contractions was increased in a dose-dependent manner, whereas the spikes frequency known to determine the contractions amplitude was reduced within the range of low concentrations. At a high concentration of 1 mM $Mn^{2+}$, however, all spontaneous contractile responses were blocked simultaneously with the disapperance of electrical activity. 6) The frequency and amplitude of spontaneous contractions altered by $Mn^{2+}$ in 1mM $Ca^{2+}$ Tyrode were increased by extra $Ca^{2+}(2mM)$.

  • PDF

Optical frequency locked loop using quadricorrelator (Quadricorrelator 방식을 이용한 광주파수 잠김루프 제작)

  • 유강희;박창수;박진우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3286-3292
    • /
    • 1996
  • An experimental results of optical requency locked loop with DFB semiconductor laser as VCO are presented. Using quadricorrelator as frequency difference detector and frequency off-set locking technique with 1GHz reference frequency, frequency locking range of 140MHz was achieved. This paper reports the design and realization details of the loop.

  • PDF

Vocal acoustic characteristics of speakers with depression (우울증 화자 음성의 음향음성학적 특성)

  • Baek, Yeon-Sook;Kim, Se-Joo;Kim, Eun-Yeon;Choi, Yae-Lin
    • Phonetics and Speech Sciences
    • /
    • v.4 no.1
    • /
    • pp.91-98
    • /
    • 2012
  • The purposes of this paper is to study the characteristics of compared to the speakers voice without depression and speakers with depression, and to propose a objective method for the measurement of the therapeutic effects as well as for diagnostics of depression based on the characteristics. The voice samples obtained from 11 female speakers with depression, aged from 20 to 40, diagnosed as having major depressive disorder by an psychiatrist were compared with those from 12 normal controls with matched sex, age, height, weight, education, smoking, and drinking. The voice samples are taken by a portable digital recorder(TASCAM DR-07, Japan) and analysed using the MDVP(Multi-Dimentional Voice Program) software module from CSL(Computerized Speech Lab, kay elemetrics, co, model 4100). The result of the investigation are as following. First, the average speaking fundamental frequency and loudness range of the speakers with depression group was statistically significantly lower than that of the control group. The pitch range of the control group was rather higher than that of the speakers with depression group, but without statistical significance. Overall speech rates have no statistical difference between two groups. Second, the average speaking fundamental frequency and loudness range have statistically significant negative correlation with Beck Depression Inventory, i. e. more severe depression exhibits lower average speaking fundamental frequency and loudness range. Other vocal parameters such as pitch range and overall speech rate have no statistically meaningful correlations with Beck Depression Inventory.

A Study on the Applicability of Smart-phone Accelerometer for the Measurement of Dynamic Behavior in Bridges (교량의 동적 거동 계측을 위한 스마트폰 가속도센서의 적용성에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.747-756
    • /
    • 2020
  • In recent years, measurement in a smart-phone environment is attracting attention in various fields due to its easy set-up process, various functions, convenience and expandability. Even in the field of safety evaluation and maintenance of large-scale infra-structures, the appropriate application of these effective and convenient measurement techniques can be of great help. In this paper, an experimental study was conducted to investigate the effectiveness, problems and complementary methods of applying smart-phone accelerometers to the measurement in infra-structure such as bridges. In model bridge subjected to impact and moving loads, the measured accelerations using a smart-phone and a professional accelerometer were directly compared in time domain. And the statistical and frequency characteristics of the measured signal and transfer function were also examined in frequency domain. The results show that the accuracy of measurement using smart-phone sensor is primarily affected by its incomplete sampling performance. In conclusion, smart-phone sensors cannot be considered suitable for precise assessment, where measurements must be accurate over a wide frequency range, but we can say that the technique is still useful and fairly accurate for some purpose over a limited frequency range, such as the low pass frequency range, which is a major concern for civil structures.

A Research on Time-Dependent Fundamental Frequency Variations after Waking up in the Morning (기상 후 시간에 따른 음도 변화에 대한 연구)

  • Ahn, Jong-Bok;Nam, Hyun-Wook;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.169-176
    • /
    • 2008
  • This study was intended to analyze difference of vocal folds movements between upon wakeup and in several hours later in the morning. The difference of vocal fold movements was compared with fundamental frequency and a range of fundamental frequencies from maximum to minimum. The participants were 30 female adults between 20 and 29 years old. Voice samples were collected from their reading sentence (Jeong, 1993). The first sampling was conducted within 5 minutes after wakeup, while the second on 1 hour after the first sampling. Finally, the third voice sample was collected on 6 hours after the second sampling. The results of this study were as follows: First, fundamental frequency of the participants were by hour significantly time-dependent(F=7.843). Post-hoc multiple comparison (LSD) was conducted to determine when the difference could be observed. The result showed significant differences between upon wakeup and 6 hours later (p< .001) and between 1 hour later and 6 hours later (p< .05). Second, there were a significantly time-dependent ranges of fundamental frequencies of participants by hour (F=3.130). According to the results of the LSD analysis the significant differences in range of fundamental frequencies were found between upon wakeup and 1 hour later and also between wakeup and 6 hours later (p< .05). The results above indicate that vocal fold movements upon wakeup is different from those of several hours later.

  • PDF

Analysis of Frequency Characteristics of Writing Instruments Due to Friction (필기구 마찰의 주파수 특성 분석)

  • Shin, JaeUn;Park, JinHwak;Lee, YoungZe
    • Tribology and Lubricants
    • /
    • v.33 no.4
    • /
    • pp.148-152
    • /
    • 2017
  • The feel of writing is important to customers when they buy smart devices with stylus such as smartphones and tablet computers. With an aim to reproduce the tactile sensibility of writing instruments when people write on the glass display using a stylus, this study focuses on the frequency characteristics of writing instruments that can describe the vibrations of writing instruments sliding over counter surfaces. In addition, this study includes the effect of various factors influencing the friction of writing instruments such as lubricant, nib material, and contact type. We perform sliding experiments with six types of writing instruments and a sheet of paper to understand the relation between the friction conditions of the nib and the frequency characteristics. As this research focuses on the tactile perception of human skin when people use a writing instrument, the analysis of frequency characteristics is performed in the perceptible frequency range of mechanoreceptors in the human skin. As a result, three types of frequency characteristics are identified. Low frequency peaks are observed for a metal nib with ink; high frequency peaks are observed for a nib without ink; and, middle frequency peaks with a wide range of distribution occurs for fabric nibs with ink. Therefore, to implement the proper feel of writing, at least three types of vibrations have to be made.

Design of PLL Frequency Synthesizer for a 915MHz ISM Band wireless transponder using CPFSK communication (CPFSK communication 사용한 915MHz ISM Band 위한 PLL Frequency Synthesizer 설계)

  • Kim, Seung-Hoon;Cho, Sang-Bock
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.286-288
    • /
    • 2007
  • In this paper, the fast locking PLL Frequency Synthesizer with low phase noise in a 0.18um CMOS process is presented. Its main application IS for the 915MHz ISM band wireless transponder upon the CPFSK (Continuous Phase Frequency Shift Keying) modulation scheme. Frequency synthesizer, which in this paper, is designed based on self-biased techniques and is independent with processing technology when damping factor and bandwidth fixed to most important parameters as operating frequency ratio, broad frequency range, and input phase offset cancellation. The proposed frequecy synthesizer, which is fully-integrated and is in 320M $^{\sim}$ 960MHz of the frequency range with 10MHz of frequency resolution. And its is implemented based on integer-N architecture. Its power consumption is 50mW at 1.8V of supply voltage and core area is $540{\mu}m$ ${\times}$ $450{\mu}m$. The measured phase noises are -117.92dBc/Hz at 10MHz offset, with low settling time less than $3.3{\mu}s$.

  • PDF

A Study of the Current-Diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency (가변주파수에 있어서 유도잔동기특성의 도식산정법에 관한 연구 제3보)

  • Min Ho Park
    • 전기의세계
    • /
    • v.18 no.5
    • /
    • pp.20-25
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustable frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frequency source of which frequency is adjustable over the speed range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction motor etc. at any optional frequency. Although the characteristics can be obtained by means of the conventional methods, they require very complicated precedures of calculations. The Current Diagram Method in this paper suggests a new approach to simpler calculations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: 1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagram Method. 2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. 3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF

Design of an AM Radar Module with Improved Range Accuracy (거리 측정 정확도를 개선한 AM 레이더 모듈 설계)

  • Choi, Mun-Gak;Woo, Dong-Sik;Kang, Il-Heung;No, Hyung-Woo;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.8
    • /
    • pp.911-918
    • /
    • 2010
  • With limitation of frequency bandwidth, the range accuracy of typical radars is limited. In this paper, for short distance measurements, the use of an AM(Amplitude Modulated) radar which provides improved range accuracy is proposed. The AM radar signal consists of a carrier frequency signal and double-sideband components. The fabricated AM radar operates with +10 dBm output power and 35 dB receiver gain at 24.128 GHz center frequency with 20 MHz bandwidth, and the range accuracy is measured as ${\pm}15\;cm$.

Influence of Sustain Pulse-width on Electrical Characteristics and Luminous Efficiency in Surface Discharge of AC-PDP

  • Jeong, Yong-Whan;Jeoung, Jin-Man;Choi, Eun-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.276-279
    • /
    • 2005
  • Influences of sustain pulse-width on electrical characteristics and luminous efficiency are experimentally investigated for surface discharge of AC-PDP. A square pulse with variable duty ratio and fixed rising time of 300 ns has been used in the experiment. It is found that the memory coefficient is significantly increased at the critical pulse-width. And the wall charges and wall voltages as well as capacitances are experimentally measured by Q- V analysis method along with the voltage margin relation, in terms of the sustain pulse-width in the range of $1{\mu}s$ to $5{\mu}s$ under driving frequency of 10 kHz to 180 kHz. And the luminous efficiency is also experimentally investigated in above range of sustain pulse-width with driving frequency of 10 kHz to 180 kHz. It is noted that the luminous efficiency for 10 kHz and 180 kHz are 1.29 1m/W and 0.68 1m/W respectively, since the power consumption for 10 kHz is much less than that for 180 kHz. It has been concluded that the optimal sustain pulse-width is in the range of $2.5 {\~}4.5{\mu}s$ under driving frequency range of 10 kHz and 60 kHz, and in the range of $1.5 {\~} 2.5{\mu}s$ under driving frequency range of 120 kHz and 180 kHz based on observation of memory coefficient, and wall voltage as well as luminous efficiency.