• 제목/요약/키워드: Frequency of application

검색결과 4,301건 처리시간 0.041초

Effects of Transcutaneous Electrical Nerve Stimulation depending on Frequency and Intensity for Postural Sway during Sit to Stand with Stroke Patients

  • Byun, Dong-Uk;Shin, Won-Seob
    • The Journal of Korean Physical Therapy
    • /
    • 제25권3호
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: The application of transcutaneous electrical nerve stimulation (TENS) is beneficial for joint movements, inhibition of spasticity, and the improvement of walking ability in patients with chronic hemiplegia. This study aimed to identify the effect of the application of TENS to the knee extensor on the affected side with respect to postural-sway distance and velocity during the sit-to stand movement. Methods: We included 19 patients with post-stroke hemiplegia in this study. They underwent measurements during the sit-to stand movement on a force plate with 5 different stimulation dosages applied over 7 s:No TENS, high-frequency and high intensity TENS, high-frequency and low intensity TENS, low-frequency and high intensity TENS, and low-frequency and low intensity TENS The 5 different condition were administered in random order. Results: The group that received TENS application exhibited a significant decrease in path length and average velocity of center of pressure (COP) displacement compared with the group that did not receive TENS application. TENS dosage at low frequency (3Hz) and high intensity yielded a significant decrease in path length, average velocity, mediolateral distance and anteroposterior distance of COP displacement (p<0.05). Conclusion: Our results demonstrated the effectiveness of the application of low-frequency TENS on STS performance. These findings provide useful information on the application of TENS for the reduction of postural sway during the sit-to-stand movement after stroke.

Ethychlozate 살포가 하우스 밀감의 품질에 미치는 영향 (Effects of Ethychlozate on the Fruit Quality of Satsuma Mandarin(Citrus unshiu Marc. cv. Miyagawa Early) in the Plastic House)

  • 김용호
    • 생물환경조절학회지
    • /
    • 제7권4호
    • /
    • pp.276-282
    • /
    • 1998
  • 하우스 밀감의 품질을 향상시키고자 궁천조생 8년생을 공시하여 1월 20일부터 가온하였는데 2월 21일에 만개되었다. 만개후 100일, 115일, 145일에 ethychlozate 100mg.L$^{-1}$을 각각 1회, 2회, 3회를 살포하여 품질조사를 한 결과, 과피의 착색도 a는 살포횟수가 많아질수록 높았으며 a/b값도 이와 유사한 경향으로 살포횟수가 많아질수록 증가되어 과피의 착색이 촉진되었으나 b값은 반대의 경향으로 오히려 낮아졌다. 과육의 glucose는 ethychlozate 살포횟수간에 차이를 나타내지 않았으나 fructose는 살포횟수가 많아질수록 증가되었다. Sucrose는 fructose와 유사한 경향으로 살포횟수가 많아질수록 증가 경향이 뚜렷하였고 이러한 결과로 총당도 증가하였다 당도(Brix)는 무처리에 비해 증가되었으나 살포횟수간에는 큰 차이가 없었으며 산도도 살포횟수가 많아질수록 증가되는 경향이었으나 유의차는 없었다.

  • PDF

쇼핑 애플리케이션의 정보제공성이 애플리케이션의 선호도와 재구매의도에 미치는 영향에 관한 연구 -이용빈도를 조절효과로- (A Study on the Effect of Shopping Application Information Offering on Application Preference and Repurchase Intention : mediating effect of frequency of utilization)

  • 곽동성;임기흥;권진희
    • 디지털융복합연구
    • /
    • 제12권11호
    • /
    • pp.113-121
    • /
    • 2014
  • 최근 주요 기업들은 쇼핑 애플리케이션을 마케팅 전략으로 개발하고, 이러한 전략을 효과적으로 실행하는데 무게를 두고 있다. 이러한 애플리케이션의 특성 중 주요한 요인을 정보제공성으로 설정하고 애플리케이션 선호도가 재구매의도에 미치는 영향과 이용빈도의 조절효과에 대해 알아보고자 한다. 그 결과 쇼핑 애플리케이션의 정보제공성은 쇼핑 애플리케이션의 선호도에 영향을 미치고, 쇼핑 애플리케이션의 선호도는 재구매의도에 긍정적인 영향을 미친다. 또한 쇼핑 애플리케이션의 특성이 재구매의도에 직접 영향을 미칠 때와, 선호도를 매개로 하여 재구매의도에 미치는 영향을 비교해본 결과 선호도를 매개로 하여 미치는 영향이 더 큰 것으로 나타났다. 그리고 이용빈도의 조절 효과를 검증한 결과 이용빈도가 낮은 경우 보다 이용빈도가 높은 경우가 더 유의하다는 결과가 나타났다.

간호사의 정보기술(IT)활용이 지식관리활동에 미치는 영향 (The Effect of Information Technology Application on Knowledge Management Process in Clinical Nurses)

  • 정석희
    • 간호행정학회지
    • /
    • 제10권1호
    • /
    • pp.141-159
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the degree of information technology application, and to identify the effect of information technology application en knowledge management process in clinical nurses. Method: Participants were 629 regular clinical nurses who had worked for over 1 year in general units of 9 tertiary medical hospitals including 2 national university hospitals, 5 university hospitals, and 2 hospitals founded by business enterprises. Data were collected from March to May 2003 through questionnaires. Thee structured instruments were used to collect the data: Information Technology Application scale, Knowledge Management Process Scale(Jeong, Lee, Lee, & Kim, 2003), and one for general characteristics. The data were analyzed using reliability analysis, descriptive analysis, one-way ANOVA, $Scheff{\acute{e}$ test, correlation analysis, partial correlation analysis, and multiple regression analysis with the SPSS for Windows 10,0 program. Result: 1) The HIS application degree, IT application ability, and IT application frequency were significantly correlated with the degree of knowledge management process activation and 4 elements of knowledge management process, Knowledge Creation, Knowledge Storage, Knowledge Sharing, and Knowledge Utilization(p=.000). 2) The 3 variables, HIS application degree, IT application ability, and IT application frequency explained 47.2% of the total variance of the degree of knowledge management process activation, and 352% of me total variance of Knowledge Storage. And 2 variables, HIS application degree and IT application frequency explained 17.6% of the total variance of Knowledge Creation, 39.9% of the total variance of Knowledge sharing, and 33.8% of the total variance of Knowledge utilization(p=.000). 3) As a result of multiple regression analysis, the key determinant of the degree of knowledge management process activation for nurses was HIS application degree The HIS application degree, IT application frequency, position, IT application ability, and continuous total numbers of years working at the present hospital explained 51.1% of the total variance of the degree of knowledge management process activation(p=.000). Conclusions: These results suggest that the information technology application positively affects the nurses' knowledge management process. From the above findings, information technology application is empirically verified as a useful and effective method to activate knowledge management process, and knowledge management.

  • PDF

Detection system of Robust High Frequency Range via Noise Collection and Analysis

  • Chung, Myoungbeom
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권1호
    • /
    • pp.71-76
    • /
    • 2017
  • Recently, there are various researches using inaudible high frequencies like as wireless communication based smart devices, data transmission algorithm, indoor positioning trace technologies. However, when they use high frequencies of inaudible range, they have a problem that the accuracy of data transmission with high frequencies was low because of interference from ambient noise in our real life. To solve this problem, in this paper, we proposed an application based on smart phone and server system for collection of ambient noise and detection of robust high frequency range. The server system could detect the robust high frequency range from statistical analysis of collected noise and the robust high frequency could avoid interference from ambient noise. We tested the proposed application's ability to gather noise and high frequencies for a certain period of time to evaluate performance. According to the testing results, we confirmed that the proposed application and server system could detect a robust high-frequency range via noise analysis in real life. Therefore, the proposed application and server could be a useful technology for future research on inaudible high frequencies.

국내(國內) 인텔리전트 사무소(事務所) 건물(建物)의 건축계획(建築計劃) 관련지표(關聯指標) 추이(推移) 분석(分析) (An Analysis of the Transition of Architectural Data on the Intelligent Office Building in Korea)

  • 변계성
    • 한국디지털건축인테리어학회논문집
    • /
    • 제2권1호
    • /
    • pp.24-31
    • /
    • 2002
  • The purpose of this study was to analyze the transition on architectural data such as valid indoor length, module, ratio of core, floor height, ceiling height and the type of structured cabling system according to the intelligent building grade through case study of the intelligent office buildings constructed in Korea since 1980. The results of this study were as follows. The average floor height was 3.80m, and it was higher in proportion to the IB grade. The average ceiling height was 2.57m, and it didn't have connection with the IB grade. The module of high frequency in application was $3.0{\times}3.0m$, and it showed 25% in the application frequency. The average valid indoor length was 12.27m. The average ratio of core was 24.49%. The type of high frequency in application for the structured cabling was Access Floor Type, and it showed 31% in the application frequency.

  • PDF

Experimental Investigation of a High-repetition-rate Pr3+:YLF Laser with Single-frequency Oscillation

  • Dai, Weicheng;Jin, Long;Dong, Yuan;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • 제5권6호
    • /
    • pp.721-729
    • /
    • 2021
  • We demonstrate a Pr3+:YLF 639.7-nm laser with single-frequency output based on the Q-switched pre-lase technology, pumped by a fiber-coupled GaN blue laser diode. The pre-lase technology is realized by the step-type loss of the acousto-optical Q-switched device. The conclusions of the theoretical research are verified experimentally. The mode-suppression ratio was 44 dB at the single-frequency laser output. Detection by interferometer verified the realization of the stable single-frequency laser. In addition, the emission spectrum had a linewidth of 139.9 MHz, measured by Fabry-Perot interferometer. The single-frequency laser's single-peak power was over 19.7 W with 98.8-ns pulse duration, obtained under an absorption power of 1.74 W.

부호분할다중화 통신시스템을 위한 다중루프 PLL주파수 합성기에서의 주파수분주정수에 관한 해석 (An analysis of frequency divider ratio in N-loop PLL frequency synthesizer for CDMA communication system)

  • 김도욱;한영열
    • 한국통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.54-62
    • /
    • 1988
  • 본 논문에서는 부호분할다중접근을 위한 주파수도약대역확산통신방식의 통신시스템을 구현하는데 기본적으로 필요한 요소인 주파수합성기에 대하여 각 사용자에게 부여된 번지에 따라 원하는 도약형태로 주파수를 출력시키는데 적합하고 실제 시스템의 구현이 용이하도록 다중루프 PLL 주파수합성기의 모델을 제시하였으며 원하는 주파수를 출력시키는데 필요한 주파수분주정수의 분포와 그 결정방법, 그리고 이 분주정수와 다중도에 따른 대역통과필터의 대역폭의 변화에 대해 분석하였다.

  • PDF

A Real-time Tinnitus Treatment System Using Tinnitus Frequency Removal and Adjacent Frequency Amplification on Mobile Device

  • Park, Dae-Hyun;Kim, Yoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권11호
    • /
    • pp.111-118
    • /
    • 2015
  • In this paper, we propose a new tinnitus treatment system that removes the frequency band where the ear noises is generated and amplifies the around frequency bands in order to treat a nonstop buzzing in the ears, that is one among the disease commonly generated in modern people. Mostly the tinnitus is generated by the tunability with the neighboring nerves while the part of the cerebral cortex which is unable to react to the stimuli by the sound of the specific frequency band reacts to other frequency band. Therefore, the excitability activity by the tunability of the cerebral cortex is suppressed and the remedial value is gotten by removing the tinnitus frequency band, and the around frequency bands are amplified to strengthen the remedial value. Experimental results show that the tinnitus can be treated conveniently if the patients use the android application which the proposed technique is applied to.

순간주파수 분석기법의 응용 (2) -주파수의 부호를 결정하는 조건- (Application of Instantaneous Frequency Analysis(II) -Conditions of Existing Negative Frequency Components-)

  • 김정태;임병덕
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.1057-1063
    • /
    • 1994
  • An instantaneous frequency analysis is a technique to examine a signature for the rotating machinery if the signal has several transitions within a cycle. This paper discusses the conditions of existing negative frequency components in the instantaneous frequency. By using a signal consisted of two frequency components, the instantaneous frequency analysis is conducted while the amplitude ratio between two frequency components has been changed. The analysis shows that, depending on the amplitude ratio, the instantaneous frequencies have averaged, zero-valued, or negative components. It turns out that the negative-valued instantaneous frequencies, which have been regarded as the noise effect, are the consequence of the calculation process for the multisignal components. The criteria of existing the negative values in instantaneous frequencies is given in terms of the relative amplitude ratio and the frequency difference. Especially when the amplitude ratio approaches to 1, the instantaneous frequency fluctuates ${\pm}\infty$ in theory, which implies that instantaneous frequency has unstable region around the amplitude ratio, 1.Also, as the frequency difference between major signal components is increased, the region of existing negative instantaneous becomes broader. In an instantaneous frequency analysis, therefore, a narrow band analysis is suggested, with extreme care if the amplitude ratio approaches to 1. In this paper, a vibration signal monitored from a rotating machinery is also examined as an application example in order to show the existence of negative instantaneous frequencies components.