• Title/Summary/Keyword: Frequency Sweep

검색결과 150건 처리시간 0.024초

Vibration Fixture design for small satellite launch vehicle environment test (인공위성발사체 상단부 진동환경시험을 위한 치구설계)

  • Jeong, Ho-Kyeong;Seo, Sang-Hyun;Park, Soon-Hong;Jang, Young-Soon;Yi, Yeoung-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.258-262
    • /
    • 2007
  • Satellite launch vehicle is exposed to some dynamic environment during its flight. Particularly, the safety of launch vehicle structure is surely verified under vibration environment in low frequency range. Sine sweep test is generally performed to describe this low frequency vibration environment. Dynamic property of vibration fixture is considered to get the correct property of target object. This vibration fixture should really be an extension of the armature in the form of a very rigid structure that can transfer the required force at the required frequency. An optimum fixture would have its lower natural frequency about 50% higher than the highest required forcing frequency in order to avoid fixture resonances during the test. In this study, the vibration mode analysis considering the mass of target object to design the vibration fixture. And the modal test of vibration fixture is performed to conform the design.

  • PDF

A SENSITIVITY ANALYSIS OF THE KEY PARAMETERS FOR THE PREDICTION OF THE PRESTRESS FORCE ON BONDED TENDONS

  • Jang, Jung-Bum;Lee, Hong-Pyo;Hwang, Kyeong-Min;Song, Young-Chul
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.319-328
    • /
    • 2010
  • Bonded tendons have been used in reactor buildings at some operating nuclear power plants in Korea. Assessing prestress force on these bonded tendons has become an important pending problem in efforts to assure continued operation beyond their design life. The System Identification (SI) technique was thus developed to improve upon the existing indirect assessment technique for bonded tendons. As a first step, this study analyzed the sensitivity of the key parameters to prestress force, and then determined the optimal parameters for the SI technique. A total of six scaled post-tensioned concrete beams with bonded tendons were manufactured. In order to investigate the correlation of the natural frequency and the displacement to prestress force, an impact test, a Single Input Multiple Output (SIMO) sine sweep test, and a bending test using an optical fiber sensor and compact displacement transducer were carried out. These tests found that both the natural frequency and the displacement show a good correlation with prestress force and that both parameters are available for the SI technique to predict prestress force. However, displacements by the optical fiber sensor and compact displacement transducer were shown to be more sensitive than the natural frequency to prestress force. Such displacements are more useful than the natural frequency as an input parameter for the SI technique.

The Ballast for HID Lamps of Preventing the Overvoltage with a Long Distance Resonant Ignition (원거리 공진 기동시 과전압 방지 HID 안정기)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권1호
    • /
    • pp.94-102
    • /
    • 2015
  • The electronic ballast for HID lamps needs to ignite lamps even though the length from the ballast to lamp is far away. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps because the reduction of ignition voltage is not much depending on the distance. However, the parasitic capacitance is increased depending the length of the cable, and it affects the resonant frequency. The ignitor voltage can be increased drastically under the resonant ignition through frequency sweep, and it is the main reason of blowing up. Therefore, the clamping diode is proposed to suppress the voltage of the primary winding during resonant ignition.

Fabrication and Output Characteristics of a High-Speed Wavelength Swept Mode-Locked Laser (고속 파장가변 모드잠김 레이저의 제작 및 출력특성)

  • Lee, Eung-Je;Kim, Yong-Pyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제56권6호
    • /
    • pp.1117-1121
    • /
    • 2007
  • We demonstrate a wavelength swept mode-locked ring laser for the frequency domain optical coherence tomography(FD OCT). A laser is constructed by using a semiconductor optical amplifier, fiber Fabry-Perot tunable filter and 2.6 km fiber ring cavity. Mode-locking is implemented by 2.6 km fiber ring cavity for matching the fundamental or harmonic of cavity roundtrip time to a sweep period. The wavelength sweeps are repetitively generated with the repetition period of 77.2 kHz which is the parallel resonance frequency of Fabry-Perot tunable filter for the low driving current consumption of the fiber Fabry-Perot tunable filter. The wavelength tuning range of the laser is more than FWHM of 61 nm centered at the wavelength of 1320 nm and the linewidth of the source is $0.014{\pm}0.002$ nm.

Behavior of the Flexural Vibration Damping of a Sandwich Beam System with a Partially Inserted Viscoelastic Layer (점탄성층이 부분적으로 삽입된 샌드위치보의 횡진동 감쇠특성)

  • Park, Jin-Taek;Yu, Hyeong-Won;Jang, Seok-Won;Choe, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제26권2호
    • /
    • pp.225-233
    • /
    • 2002
  • The flexural vibration characteristics of a sandwich beam system with a partially inserted viscoelastic layer have been quantitatively studied using a finite element analysis in combination with a sine-sweep test. Antisymmetric mode shapes of the flexural vibration were visualized by the holographic interferometry and agreed with those calculated by the finite element simulation. Effects of the beam thickness as well as the length and thickness of partial viscoelastic layers on the system loss factor(η$\_$s/) and resonant frequency($\omega$$\_$r/) were significantly large fur the symmetric and antisymmetric modes of the beam system.

Nonlinear Dynamic Characteristics of Deployable Missile Control Fin (접는 미사일 조종날개의 비선형 동특성)

  • Kim, Dae-Kwan;Bae, Jae-Sung;Lee, In;Shin, Young-Sug;Lee, Yeol-Wha
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제12권10호
    • /
    • pp.808-815
    • /
    • 2002
  • The nonlinear characteristics for hinge of a deployable missile control fin are investigated experimentally. The nonlinearity is caused by a worn or loose hinge and manufacturing tolerance and cannot be eliminated completely. The structural nonlinearity has an effect on the static and dynamic characteristics of the control fin. Therefore, it is necessary to establish the accurate nonlinear model for the hinge of the control fin. In the present study the existence of nonlinearities in the hinge is confirmed from the frequency response experiments such as tip random excitation and base sine sweep. Using the system identification method. especially, ″Force-state Mapping Technique″, the types of nonlinearities are identified and the nonlinear hinge model of the control fin is established.

Nonlinear Hinge Dynamics Estimation of Deployable Missile Control Fin (접는 미사일 조종날개의 비선형 힌지 동특성 파악)

  • Kim, Dae-Kwan;Bae, Jae-Sung;Lee, In;Woo, Sung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.848-854
    • /
    • 2002
  • The nonlinear characteristics for the hinge of a deployable missile control fin are investigated experimentally. The nonlinearity is caused by a worn or loose hinge and manufacturing tolerance and cannot be eliminated completely. The structural nonlinearity has an effect on the static and dynamic characteristics of the control fin. Therefore, it is necessary to establish the accurate nonlinear model for the hinge of the control fin. In the present study the existence of nonlinearities in the hinge is confirmed from the frequency response experiments such as tip random excitation and base sine sweep. Using the system identification method, especially, “Force-State Mapping Technique”, the types of nonlinearities are identified and the nonlinear hinge model of the control fin is established.

  • PDF

Fatigue Life Estimation of Solid-state Drive due to the Effect of Dummy Solder Ball under Forced Vibration (Solid-state drive 강제진동시 dummy solder ball 효과에 의한 피로수명 예측)

  • Lee, Juyub;Jang, Gunhee;Jang, Jinwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.978-983
    • /
    • 2014
  • This research proposes a method to estimate the fatigue life of solid-state drive(SSD) due to the effect of dummy solder ball under forced vibration. Mechanical jig is developed to describe the SSD in laptop computer. The jig with SSD is mounted on a shaker, and excited by a sinusoidal sweep vibration within the narrow frequency band around the first resonant frequency until the SSD fails. A finite element model of SSD is also developed to simulate the forced vibration. It shows that the solder joints at the corners of controller package are most vulnerable components and that placing dummy solder balls at those area is effective method to increase fatigue life of SSD.

  • PDF

Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

Current-controllable saw-tooth waveform generators using current-tunable Schmitt trigger (전류-제어 슈미트 트리거를 이용한 전류-제어 톱니파 발생기)

  • Chung, Won-Sup;Lee, Myung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제44권7호통권361호
    • /
    • pp.31-36
    • /
    • 2007
  • A saw-tooth waveform generator whose frequency can be controlled with a do bias current is proposed. The generator utilizes operational transconductance amplifiers (OTA's) as switching element. It features simple and wide sweep capability The circuit built with commercially avaliable components exhibits good linearity of current-to-frequency transfer characteristics and relatively low temperature sensitivity.