• Title/Summary/Keyword: Frequency Sweep

Search Result 150, Processing Time 0.028 seconds

Imaging Technique Based on Continuous Terahertz Waves for Nondestructive Inspection (비파괴검사를 위한 연속형 테라헤르츠 파 기반의 영상화 기술)

  • Oh, Gyung-Hwan;Kim, Hak-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.328-334
    • /
    • 2018
  • The paper reviews an improved continuous-wave (CW) terahertz (THz) imaging system developed for nondestructive inspection, such as CW-THz quasi-time-domain spectroscopy (QTDS) and interferometry. First, a comparison between CW and pulsed THz imaging systems is reported. The CW-THz imaging system is a simple, fast, compact, and relatively low-cost system. However, it only provides intensity data, without depth and frequency- or time-domain information. The pulsed THz imaging system yields a broader range of information, but it is expensive because of the femtosecond laser. Recently, to overcome the drawbacks of CW-THz imaging systems, many studies have been conducted, including a study on the QTDS system. In this system, an optical delay line is added to the optical arm leading to the detector. Another system studied is a CW-THz interferometric imaging system, which combines the CW-THz imaging system and far-infrared interferometer system. These systems commonly obtain depth information despite the CW-THz system. Reportedly, these systems can be successfully applied to fields where pulsed THz is used. Lastly, the applicability of these systems for nondestructive inspection was confirmed.

Temperature and Concentration measurement using Semi-conductor diode laser (반도체레이져를 이용한 온도 및 농도의 계측)

  • Chung, D.H.;Noh, D.S.;Ikeda, Yuji
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF

Circuit Modelling and Eigenfrequency Analysis of a Poly-Si Based RF MEMS Switch Designed and Modelled for IEEE 802.11ad Protocol

  • Singh, Tejinder;Pashaie, Farzaneh
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.3
    • /
    • pp.129-136
    • /
    • 2014
  • This paper presents the equivalent circuit modelling and eigenfrequency analysis of a wideband robust capacitive radio frequency (RF) microelectromechanical system (MEMS) switch that was designed using Poly-Si and Au layer membrane for highly reliable switching operation. The circuit characterization includes the extraction of resistance, inductance, on and off state capacitance, and Q-factor. The first six eigenfrequencies are analyzed using a finite element modeler, and the equivalent modes are demonstrated. The switch is optimized for millimeter wave frequencies, which indicate excellent RF performance with isolation of more than 55 dB and a low insertion loss of 0.1 dB in the V-band. The designed switch actuates at 13.2 V. The R, L, C and Q-factor are simulated using Y-matrix data over a frequency sweep of 20-100 GHz. The proposed switch has various applications in satellite communication networks and can also be used for devices that will incorporate the upcoming IEEE Wi-Fi 802.11ad protocol.

Design of the Transceiver for a Wide-Range FMCW Radar Altimeter Based on an Optical Delay Line (광 지연선 기반의 넓은 고도 범위를 갖는 고정밀 FMCW 전파고도계 송수신기 설계)

  • Choi, Jae-Hyun;Jang, Jong-Hun;Roh, Jin-Eep
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1190-1196
    • /
    • 2014
  • This paper presents the design of a Frequency Modulated Continuous Wave(FMCW) radar altimeter with wide altitude range and low measurement errors. Wide altitude range is achieved by employing the optic delay in the transmitting path to reduce the dynamic range of measuring altitude. Transmitting power and receiver gain are also controlled to have the dynamic range of the received power be reduced. In addition, low measurement errors are obtained by improving the sweep linearity using the Direct Digital Synthesizer(DDS) and minimizing the phase noise employing the reference clock(Ref_CLK) as the offset frequency of the Phase Locked Loop(PLL).

Experiments for the Vibration Control of Steel Frame Structure Using Toggle Brace and Lead Rubber Damper (토글가새와 납-고무 제진장치를 적용한 구조물 진동제어 실험)

  • Park, Jung-Woo;Park, Jin-Young;Lee, Wan-Ha;Kim, Ki-Man;Park, Kun-Nok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.171-176
    • /
    • 2011
  • The purposes of the research were to evaluate system performance and response of building structure under external load for full scale modal-testing-tower applied toggle bracing and lead rubber damper(LRD). The dynamic properties of the structure were measured before and after installing damper under harmonic excitation using the AMD and the results were compared. The harmonic excitation condition is to increase 0.01Hz sine sweep signal from 0.49Hz to 0.63Hz. As a result of measuring resonant frequency, before installing damper is 0.55Hz and after installing damper is 0.62Hz. The experimental results after installing damper were also distinguished from simulation results and the main cause of this results is temperature dependency property of rubber material.

  • PDF

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

Vibration Characteristics of Patterned IPMC Actuator (패턴된 IPMC 작동기의 진동특성)

  • Jeon, Jin-Han;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.718-721
    • /
    • 2007
  • The ionic-polymer-metal-composite actuators have the best merit for bio-mimetic locomotion because of their large bending performance. Especially, they have the advantage for mimicking a fish-like motion because IPMCs are useful to be actuated in water. So we have developed IPMC actuators with multiple electrodes for realization of biomimetic motion. This actuator is fabricated by combining electroless plating and electroplating techniques capable of patterning precisely and controlling a thickness of Pt electrode layer. The FRF analysis was conducted by a mechanical shaker and direct electrical excitation which is based on sweep sine wave function. From this result, the proper young‘s modulus of Platinum was investigated and applied on expecting the vibration characteristics of patterned IPMC actuator. The calculated maximum displacement of the patterned IPMC was 2.32mm under an applied 4mN/mm. The natural frequency was increased however displacement was decreased in according to increase a thickness of Pt.

  • PDF

Construction of High-Speed Wavelength Swept Mode-Locked Laser Based on Oscillation Characteristics of Fiber Fabry-Perot Tunable Filter (광섬유 패브리-페로 파장가변 필터의 공진특성에 기반한 고속 파장가변 모드잠김 레이저의 제작)

  • Lee, Eung-Je;Kim, Yong-Pyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1393-1397
    • /
    • 2009
  • A high-speed wavelength swept laser, which is based on oscillation characteristics of a fiber Fabry-Perot tunable filter, is described. The laser is constructed by using a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, and 3.348 km fiber ring cavity. The wavelength sweeps are repeatatively generated with the repetition period of 61 kHz which is the first parallel oscillation frequency of the Fabry-Perot tunable filter for the low power consumption. Mode-locking is implemented by 3.348 km fiber ring cavity for matching the fundamental of cavity roundtrip time to the sweep period. The wavelength tuning range of the laser is 87 nm(FWHM) and the average output power is 1.284 mW.

Low-frequency switching occurs when the over-current study of 2stage electronic ballast for HID Lamps. (2단 구성 HID LAMP 전자식 안정기의 저주파수 절체 시 발생되는 과전류에 관한 연구.)

  • Lee, Seung-min;Sung, Kook-nam;Lee, Woo-cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.479-480
    • /
    • 2011
  • 본 논문은 150W HID 램프용 안정기의 공진 점등에 관한 것으로, 기존의 외부 펄스에 의한 점등 시 램프와 안정기의 거리에 따른 점등전압의 감쇠를 감소시키고자 내부 LC를 이용한 공진 점화부로 하여 기능을 향상하였으나, 벅 컨버터의 인덕터와 커패시터로 공진 기동하여 고전압 점등 파형을 만드는 과정 중 스위치 전류가 커지는 문제가 발생하여, 점등을 위한 공진용 커패시터용량을 줄여 공진 Q점을 나눈 별도의 L(T1)과 C(C2, C3)를 공진 탱크로 이용하여 점등하도록 하였으며, 공진 공진주파수로의 주파수 SWEEP 및 재 점등을 하기 위하여 마이크로프로세서를 이용하였다.

  • PDF

Diagnostic technique about power transformer winding modification (전력용 변압기 권선변형 진단기술)

  • Jeon, Sang-Dong;Oh, Jang-Man;Kim, Gi-Il;Jeong, Kyu-Won;Ryu, Hee-Young;Lee, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.336_337
    • /
    • 2009
  • 전력용 변압기 운반, 설치, 고장전류 유입 등으로 권선 및 철심의 접지, 권선의 층간단락, 개방, 기계적 변형, 이탈, 구조물의 기계적 손상, 이완 등이 발생해도 현재 보유하고 있는 진단장비만으로는 정확한 이상 판단이 불가하여 변압기 해체 후 확인 하는 현실을 감안하여 변압기 기계적 변형 고장분석이 가능한 장비 도입이 필요한 시점이다. 또한 변압기 등 변전기기 고장 발생시 광범위한 고객 정전 및 복구비용이 발생(년 평균 3건)하고 있어 본 논문에서는 이러한 문제점을 해결하고자 2003년 한전에 도입된 SFRA(Sweep Frequency Response Analyzer) 주파수 반응 분석기의 진단 원리 및 권선변형 진단사례를 소개하고자 한다.

  • PDF