• 제목/요약/키워드: Frequency Scan Effect

검색결과 26건 처리시간 0.031초

스핀스캔 레티클 탐색기의 DIRCM 재밍효과 분석 (DIRCM Jamming Effect Analysis of Spin-Scan Reticle Seeker)

  • 안상호;김영춘;이광세;김기홍;김성수
    • 한국군사과학기술학회지
    • /
    • 제12권6호
    • /
    • pp.776-784
    • /
    • 2009
  • The function of DIRCM(Directed Infrared Countermeasures) jamming is to cause the missile to miss its intended target by disturbing the seeker tracking process. The DIRCM jamming uses the pulsing flashes of IR energy and its frequency, phase and intensity have influence on the missile guidance system. In this paper, we analysis the DIRCM jamming effect of spin-scan reticle seeker. Simulation results show that the jamming effect is greatly influenced by frequency, phase and intensity of the jammer signal.

위성통신 능동 위상배열 안테나에서 주파수 스캔 효과로 발생하는 빔 지향 오차의 보상 (Correction of Beam Direction Error caused by Frequency Scan Effect in Active Phased Array Antenna for Satellite Communications)

  • 전순익;오승엽
    • 한국전자파학회논문지
    • /
    • 제14권4호
    • /
    • pp.413-420
    • /
    • 2003
  • 본 논문에서는 위성통신용 능동 위상배열 안테나에서 주파수 스캔 효과에 의하여 발생하는 안테나 빔 패턴의 지향 오차를 보상하는 방법을 제안한다. 능동 위상배열 안테나가 두 개의 빔 패턴을 위하여 두 개의 배열이 직렬 연결되고 배열 수가 비대칭인 경우에, 두 빔의 적용 주파수가 다르고 주파수 간격이 크며 빔 폭이 좁고 스캔각이 크면 안테나는 주파수 스캔 효과에 의해 빔 지향 오차가 발생한다 제안되는 수식을 사용하면, 빔 지향오차 각을 예측하여 계산할 수 있으며 이를 보상하는 능동 위상배열 안테나의 위상제어 값을 계산할 수 있다. 본 논문에서는 첫째 층 32$\times$4 배열과 둘째 층 4$\times$2 배열 구조로부터 두 개의 안테나 빔을 가지고, 7.25 GHz~7.75 GHz 주파수 대역에서 두 빔의 주파수 편차가 최대 500 MHz(6.7 %)이며, 주파수 스캔 범위가 0$^{\circ}$~$\pm$35$^{\circ}$이고, 35.6 dBi 이득과 2.2$^{\circ}$의 3 dB 빔 폭을 가지는 능동 위상배열 안테나 시스템을 제작하고, 주파수 스캔효과에 의한 빔 지향 오차를 제안된 방법의 적용 전과 적용 후에 측정 비교하였다. 주파수 스캔 효과에 의한 빔 지향 오차는 보상 전에 최대 2.5$^{\circ}$였으나, 보상 후에는 최대 0.2$^{\circ}$오차로 감소하였다. 제안된 보상으로 안테나 시스템은 7 dB 신호감쇄가 보상되었다. 제안된 보상으로 능동 위상배열 안테나는 통신을 위한 목표 위성을 정확하게 지향할 수 있다.

피코초 레이저를 이용한 Eagle Glass 절단 시 가공성 평가 (Processing Evaluations of the Eagle Glass Cutting Using Pico-second Laser)

  • 이상균;이영곤;김재도
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.403-408
    • /
    • 2013
  • In this paper, the characteristics of ablation processing of the eagle glass by pico-second laser are investigated. The laser ablation is used to process micro forms on materials. The ablation causes little thermal effect and little burr on the surface of eagle glass. In order to examine the characteristics of panic cracks, experiments are conducted under various cutting conditions such as a frequency of 600 kHz, laser powers, scan speeds and number of scan(NS). To minimize the panic cracks, the specimens are heated at $30^{\circ}C$, $45^{\circ}C$, and $60^{\circ}C$ for ten minutes respectively and then they are broken by hands. Laser powers, NS and scan speeds have an effect on glass cutting results. The ablation depths increase with an increase in the laser power and NS whereas the panic cracks decrease with an increase in scan speed. The high temperature on processed specimens reduces the panic cracks and makes good results of laser cutting. The optimal condition for eagle glass laser cutting is found to be at 30 W of laser power, 3 mm/s of scan speed and 500 of NS, respectively.

In Orbit Radiometric Calibration Tests of COMS MI Infrared Channels

  • Jin, Kyoung-Wook;Seo, Seok-Bae
    • 대한원격탐사학회지
    • /
    • 제27권3호
    • /
    • pp.369-377
    • /
    • 2011
  • Since well-calibrated satellite data is critical for their applications, calibration and validation of COMS science data was one of the key activities during the IOT. COMS MI radiometric calibration process was divided into two phases according to the out-gassing of the sensor: calibrations of the visible (VI) and infrared (IR) channels. Different from the VIS calibration, the calibration steps for the IR channels followed additional processes to secure their radiometric performances. Primary calibration steps of the IR were scan mirror emissivity correction, midnight effect compensation, slope averaging and 1/f noise compensation after a nominal calibration. First, the scan mirror emissivity correction was conducted to compensate the variability of the scan mirror emissivity driven by the coating material on the scan mirror. Second, the midnight effect correction was performed to remove unreasonable high spikes of the slope values caused by the excessive radiative sources during the local midnight. After these steps, the residual (difference between the previous slope and the given slope) was filtered by a smoothing routine to eliminate the remnant random noises. The 1/f noise compensation was also carried out to filter out the lower frequency noises caused from the electronics in the Imager. With through calibration processes during the entire IOT period, the calibrated IR data showed excellent performances.

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

RF Heating of Implants in MRI: Electromagnetic Analysis and Solutions

  • Cho, Youngdae;Yoo, Hyoungsuk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권2호
    • /
    • pp.67-75
    • /
    • 2020
  • When a patient takes an MRI scan, the patient has a risk of unexpected injuries due to the intensive electromagnetic (EM) field. Among the injuries, the tissue heating by the time-varying EM field is one of the main issues. Since an implanted artificial structure with a conductive material aggravates the heating effect, lots of studies have been conducted to investigate the effect around the implants. In this review article, a mechanism of RF heating around the implants and related studies are comprehensively investigated.

Q-Scan을 이용한 학령전기 아동의 구강보건교육 효과 (Effect of Oral Health Education with Q-Scan in Preschool Children)

  • 김나연;이수영
    • 치위생과학회지
    • /
    • 제15권6호
    • /
    • pp.696-702
    • /
    • 2015
  • 본 연구는 유치원에 다니는 아동 총 59명을 대상으로 Q-scan을 이용한 구강보건효과를 평가하고자 하였다. 유아용 면접설문지와 Quigley & Hein index를 측정하여 다음과 같은 결과를 얻었다. 아동의 치면세균막지수는 Q-scan을 이용한 중재군에서 12% 더 유의하게 감소한 것으로 나타났다(p<0.001). 구강보건지식은 두 집단 모두 불소에서 유의한 차이가 나타났으며(p<0.05), 대조군에서는 치아에 나쁜 음식에 대한 정답률도 유의하게 증가하였다(p<0.05). 구강보건태도에서 중재군은 모든 변수에서 유의한 차이가 나타났으며(p<0.05), 대조군에서는 정기 구강검진, 칫솔질 횟수에서 유의한 차이가 나타났다(p<0.05). 구강보건행동에서 중재군은 칫솔 잡는 법에서는 정답률이 증가하고, 알맞은 치약 짜기에서는 정답률이 감소하는 유의한 결과가 나타났으며(p<0.05), 대조군은 모든 변수에서 유의한 차이가 나타나지 않았다. 이러한 결과를 종합해 보면 Q-scan은 구강보건교육 시 아동들의 동기 부여를 위한 적절한 도구로 활용될 수 있을 것으로 생각된다.

진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향 (Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change)

  • 최관용;임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

LIPCA에 공급되는 전기장의 변화가 PZT 특성과 적층배향에 미치는 영향 (The Effect of Variable Electric Fields on the PZT Characteristic and Laminate Configuration in LIPCA)

  • 김철웅;남인창;윤광준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.397-398
    • /
    • 2006
  • The advanced piezoelectric ceramic composite actuator, which is called LIPCA with the FRP and the optimization of the laminate configuration, was performed to maximize the stress transfer and the fiber bridging effect. This study evaluated the effect of variable electric fields on the PZT characteristic, laminate configuration and fatigue characteristics under the resonance frequency, which meant the largest performance range and the changes of its interlaminar phase were also evaluated by stages. In conclusions, Comparing with the fatigue lift of intact LIPCA, the fatigue life of LIPCA embedded by the artificial delamination was decreased up to 50%. The micro void growth and the coalescence of epoxy were actively made at the interlaminar phase subject to the large tensile stress.

  • PDF

RF-MBE 성장조건에 따른 InGaN 단결정 박막의 결정성 관찰 (Effect of Growth Conditions on Crystal Quality of InGaN Epitaxial Layers Grown by RF-MBE)

  • 나현석
    • 열처리공학회지
    • /
    • 제31권5호
    • /
    • pp.237-243
    • /
    • 2018
  • In-rich InGaN epilayers were grown on (0001) sapphire substrates by radio-frequency plasma-assisted molecular beam epitaxy (RF-MBE). InGaN epilayers grown at various growth condition were observed by SEM, XRD, and RHEED. When plasma power of nitrogen increased from 290 to 350 W, surface morphology and crystal quality became worse according to more active nitrogen on the surface of InGaN at N-rich growth condition. As In composition was reduced from 89 to 71% by changing the incoming flux of In and Ga, surface morphology and crystal quality became worse. In addition, weak peaks of cubic InGaN phase was observed from InGaN layer with 71% In composition by XRD ${\Phi}$ scan measurement. When growth temperature decreased from 500 to $400^{\circ}C$, RHEED diffraction pattern was changed to be from streaky to spotty which means atomically rough surface, and spotty pattern showed cubic symmetry of InGaN clearly. XRD ${\Phi}$ scan measurement gave clear evidence that more cubic InGaN phase was formed at low growth temperature. All these results indicates that extremely low surface mobility of Ga adatom caused inferior crystal quality and cubic InGaN phase.