Loop-loop EM inversion and its applicability to subsurface exploration

  • Sasaki, Yutaka
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.3-6
    • /
    • 2006
  • There are three types of frequency-domain loop-loop EM induction method, depending on the loop separation and their location relative to the ground surface: horizontal-loop EM (HLEM), fixed small-loop EM, and helicopter-borne EM (HEM) methods. Multidimensional inversion provides tomographic images of the subsurface resistivity structure and thus enhances the interpretational accuracy of loop-loop EM data. HLEM method is shown to be effective for exploring groundwater resources in weathered and fractured crystalline basement terrains in semi-arid regions. Also, HEM method is useful for locating weak zones in landslide areas. The applicability of inversion to small-loop EM data depends solely on the S/N ratio. The quadrature response of small-loop EM data can only give the equivalent conductivity of a homogenous half-space model, and thus the in-phase component is essential in inverting EM data. However, the in-phase response is much lower and decreases more rapidly with decreasing frequency than the quadrature response. Further work is needed to obtain conductivity-depth images from small-loop EM data.

  • PDF

Model Updating Using Sensitivity of Frequency Response Function (주파수 응답함수의 감도를 이용한 모델개선법)

  • Kim, K.K.;Kim, Y.C.;Yang, B.S.;Kim, D.J.
    • Journal of Power System Engineering
    • /
    • v.4 no.2
    • /
    • pp.71-76
    • /
    • 2000
  • It is well known that finite element analysis often has the inaccuracy when they are in conflict with test results. Model updating is concerned with the correction of analytical model by processing records of response from test results. This paper introduce a model updating technique using the frequency response function data. The measurement data is able to be used directly in the FRF sensitivity method because it is not necessary to identify. When a damping model is updated, it is necessary for the sensitivity matrix to be divided Into the complex part and real part. As an applying model, a cantilever and a rotor system are used. Specially the machined clearance($C_p$) of the journal bearing is updated.

  • PDF

Structural Damage Detection for Metal Panel Using Embedded Sensitivity Functions (내재민감도 함수를 이용한 단열타일의 손상 탐지 기법)

  • Yang, Chul-Ho;Adams, Douglas E.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.697-705
    • /
    • 2005
  • Vibration-based damage identification method using embedded sensitivity functions is discussed. The theory of embedded sensitivity functions is reviewed and applied to identify damage in a three degree-of-freedom system and a metallic panel. Embedded sensitivity functions are algebraic combinations of measured frequency response functions that reflect changes in the response of mechanical systems when mass, damping or stiffness parameters are changed. By comparing the embedded sensitivity functions with finite difference functions using undamaged and damaged frequency response functions, damage is shown to be properly detected, located and quantified in theory and practice assuming that structures of interest are only damaged in one location. Simulated and experimental results indicate that the technique is most effective when changes to frequency response functions are small to avoid distorsions in the estimated perturbations due to variations in the sensitivity functions.

The Analysis and Compensation of DC to DC Converter with Current Mode Controller (전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구)

  • 김철진;김영태;송요창
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

The Study of Gas Sensor Using Rheological Properties of Polymeric Sensitive LB Films (고분자감응성 LB막의 유변학적인 특성을 이용한 가스센서 연구)

  • 강현욱;김정명;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.198-201
    • /
    • 1997
  • The new system for identification of organic vapours and analysis method of mechanism between organic vapours and sensitive materials were attempted using the resonant resistance and resonant frequency of Quartz Crystal Analyzer (Q. C. A.). The resonant resistance shift means rheological changes in sensitive LB films occurred by the adsorption of organic vapours, while the resonant frequency shift represent the mass of organic vapour loaded in or on the sensitive LB films. It is thought that we can obtain more accurate response mechanism of organic vapour using the resonant frequency and resonant resistance diagram. The polymeric sensitive material were quantitively depositied using the LB method. In the experimental results, the adsorption behavior of organic vapour response can be decided by two type ; surface adsorption and penetration into sensitive material. Organic vapours had different positions in the Frequency-Resistance (F-R) diagram as to the kinds and concentrations of organic vapours. Thus F-R diagram can be applied to the development of one channel gas sensing system using the Quartz Crystal Analyzer.

  • PDF

A method of measuring frequency response function by use of characteristic M-sequence

  • Sakata, Masato;Kashiwagi, Hiroshi;Kitajima, Unpei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.943-946
    • /
    • 1988
  • A simple method is proposed for determining the frequency response function G(j.omega.) of a system using a pair of characteristic M-sequences (maximum length linear feed back shift register sequence). When a characteristic M-sequence is sampled with q$_{1}$ and q$_{2}$ both of which are coprime with N, where N is the period of the M-sequence, the obtained pair of sequences have conjugate complex frequency spectrum. Making use of this fact, two charcteristic M-sequences having conjugate complex frequency spectrum are applied to a system to be measured. Since the magnitude of spectrium of M-sequence is known, the gain of G(j.omega.) is directly obtained from the Fourier transform of the system output. The phase of G(j.omega.) is obtained simply by taking the average of the two phases of output spectrum.

  • PDF

Vibration Analysis of a Cable Supported Wind Turbine Tower Model (케이블 지지된 풍력발전기 타워 구조 모델의 진동해석)

  • Kim, Seock-Hyun;Park, Mu-Yeol;Cui, C.X.
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.47-53
    • /
    • 2007
  • A theoretical model based on Rayleigh-Ritz method is proposed to predict the resonance frequency of a W/T(Wind Turbine) tower structure supported by guy cables. In order to verify the validity of the theoretical model, a reduced W/T tower system is manufactured and tested. Frequency response and mode data are determined by modal testing and finite element analysis is performed to calculate the natural frequency of the tower model. Numerical and experimental results are compared with those by the theoretical analysis. Parametric study by the theoretical model shows how the cable tension and cable elasticity influence the resonance frequency of the W/T tower structure. Finally, vibration response under various rotating speed is investigated to examine the possibility of severe resonance.

  • PDF

Methods to Obtain Approximate Responses of a Non-Linear Vibration Isolation System (비선형 진동절연 시스템의 근사적 응답을 구하는 방법)

  • Lee, Gun-Myung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.6
    • /
    • pp.23-28
    • /
    • 2020
  • A non-linear vibration isolation system composed of a non-linear spring and a linear damper was presented in a previous study. The advantage of the proposed isolator is the simple structure of the system. When the base of the isolator is harmonically excited, the response component of the mass at the excitation frequency was approximated using three different methods: linear approximation, harmonic balance, and higher-order frequency response functions (FRFs). The method using higher-order FRFs produces significantly more accurate results compared with the other methods. The error between the exact and approximate responses does not increase monotonously with the excitation amplitude and is less than 2%.

The Improvement of Leakage Error in Digital courier Transform (디지털 푸리에 변환에서 누설오차의 개선)

  • 정의봉;안세진;장호엽;장진혁
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.455-460
    • /
    • 2001
  • An exact spectrum wish no leakage error could be obtained when the period of the signal coincides perfectly with the record length. However, the record length will be determined regardless of the period of signal. The Leakage error due to this problem will gibe a distorted spectrum. In the conventional research, the method was proposed to estimate the three parameters, frequency, amplitude and phase angle, from the spectrum data for anundamped sinusoidal signal. In this paper, some techniques are proposed to estimate frequency, amplitude and damping ratios from the frequency response functions for damped signals. The validation of the proposed techniques is verified by several numerical examples.

  • PDF

Forced Vibration of Car Seat and mannequin System (자동차 시트 및 마네킹 시스템의 강제 진동)

  • Kim, Seong-Geol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.122-132
    • /
    • 2000
  • A simplified modeling approach of forced vibration for occupied car seats was demonstrated by using a mathematical model presented in 'Free Vibration of Car seat and Mannequin System' nonlinear and linear equations of motions were rederived for forced vibration and the transfer function was used to calculate the frequency response function. The experimental apparatus were set up and hydraulic shaker was used to obtain the system responses. Through the tests mannequin's head had a lot of problems and the responses with a head and without a head were measured. To explore the effects of linear dampings and friction moments at the joints linear analyses were performed. New sets of linear spring and damping coefficients and torsional dampings at the joints were calculated through parameter study to match up with experimental results. Good agreement between experimental and simulation frequency response estimates were obtained both in terms of locations of resonances and system deflection shapes at resonance indicating that this is a feasible method of modeling seated occupants.

  • PDF