• 제목/요약/키워드: Frequency Deviation

검색결과 1,441건 처리시간 0.034초

Adaptive Gain-based Stable Power Smoothing of a DFIG

  • Lee, Hyewon;Hwang, Min;Lee, Jinsik;Muljadi, Eduard;Jung, Hong-Ju;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2099-2105
    • /
    • 2017
  • In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. The simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Synthesizer (PLL Synthesizer를 이용한 새로운 FM 회로 설계 및 제작)

  • Yang, Seong-Sik;Lee, Jong-Hwan;Yeom, Kyung-Whan
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.224-228
    • /
    • 2003
  • In this paper, for phase lock loop(PLL) synthesizer, we introduce a novel but simple and low cost frequency modulation(FM) circuit of a flat peak frequency deviation for modulation signal from high to very low frequency penetrating into the loop-bandwidth of PLL. The FM circuit was basically designed to compensate an amount of feedback of the loop filter in PLL. The circuit also includes the capability of the adjustment of peak frequency deviation and blocking the interference with the loop filter. The designed circuit was successfully implemented and showed the flat frequency deviation as expected in the design.

  • PDF

Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Loop Synthesizer (PLL 주파수 합성기를 이용한 새로운 주파수 변조 회로 설계 및 제작)

  • 양승식;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제15권6호
    • /
    • pp.599-607
    • /
    • 2004
  • In this paper, using phase locked loop(PLL) synthesizer, we introduce a novel but simple and low cost frequency modulation(FM) circuit of a flat peak frequency deviation fur modulation signal whose frequency covers from outside to inside of the loop-bandwidth of PLL. The FM circuit was basically designed to compensate an amount of feedback of the loop filter in PLL. The circuit also includes the capability of the adjustment of peak frequency deviation and of blocking the intereference with the loop filter. The designed circuit was successfully implemented and showed the flat frequency deviation as expected in the design. In addition, the novel measurement method of the wideband FM modulation index is suggested verified With the suggest measurement, it can be successfully shown the designed circuit has the expected frequency deviation.

Inertial Control of a DFIG-based Wind Power Plant using the Maximum Rate of Change of Frequency and the Frequency Deviation

  • Lee, Hyewon;Kim, Jinho;Hur, Don;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.496-503
    • /
    • 2015
  • In order to let a wind generator (WG) support the frequency control of a power system, a conventional inertial control algorithm using the rate of change of frequency (ROCOF) and frequency deviation loops was suggested. The ROCOF loop is prevailing at the initial stage of the disturbance, but the contribution becomes smaller as time goes on. Moreover, its contribution becomes negative after the frequency rebound. This paper proposes an inertial control algorithm of a wind power plant (WPP) using the maximum ROCOF and frequency deviation loops. The proposed algorithm replaces the ROCOF loop in the conventional inertial control algorithm with the maximum ROCOF loop to retain the maximum value of the ROCOF and eliminate the negative effect after the frequency rebound. The algorithm releases more kinetic energy both before and after the frequency rebound and increases the frequency nadir more than the conventional ROCOF and frequency loops. The performance of the algorithm was investigated under various wind conditions in a model system, which includes a doubly-fed induction generator-based WPP using an EMTP-RV simulator. The results indicate that the algorithm can improve the frequency drop for a disturbance by releasing more kinetic energy.

Vibration Analysis of Pipe with Elbow subject to Internal Pressure and Temperature (내압 및 온도조건을 고려한 Elbow부가 있는 원형배관의 진동해석)

  • Kim, Woel-Tae;Lee, Hyun-Seung;Lee, Young-Shin;Cho, Taek-Dong;Shin, Sung-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.223-226
    • /
    • 2004
  • Vibration analysis of pipe with Elbow subject to internal pressure and temperature is studied through a commercial finite element analysis tool. The natural frequency of Elbow increased very slightly as internal pressure increases. Meanwhile, the frequency of Elbow decreased as temperature increases. It is shown that frequency deviation caused by temperature was greater than that caused by pressure. As the length of Elbows increases, frequency deviation by temperature stew rapidly, but frequency deviation by pressure was not so high. It is concluded that more concern needs to be focused on temperature rather than on pressure in terms of natural frequency.

  • PDF

Kalman Filter-Based Ensemble Timescale with 3- Hydrogen Masers

  • Lee, Ho Seong;Kwon, Taeg Yong;Lee, Young Kyu;Yang, Sung-hoon;Yu, Dai-Hyuk
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권3호
    • /
    • pp.261-272
    • /
    • 2020
  • A Kalman filter algorithm is used for the generation of an ensemble timescale with three hydrogen masers maintained in KRISS. Allan deviation curves of three pairs of clocks were obtained by a three-cornered hat method and were used as reference curves for determination of parameters of the Kalman filter-based timescale. The ensemble timescale equation of a 3-clock system was established, and the clocks' phases estimated by the Kalman filter were used as the prediction time of each clock in the equation. The weight of each clock was determined inversely proportional to the Allan variance calculated with the clocks' phases. The Allan deviation of the weighted mean was 1.2×10-16 at the averaging time of 57,600 s. However when we made fine adjustments of the clocks' weight, the minimum Allan deviation of 2×10-17 was obtained. To find out the reason of the great improvement in the frequency stability, additional researches are in progress theoretically and experimentally.

Power smoothing scheme of a wind turbine generator for reducing the frequency deviation in varying wind conditions (풍속 변동 시 주파수 유지를 위한 풍력발전기 출력 평활화 제어)

  • Kim, Yeonhee;Lee, Jinsik;Kang, Yong Cheol
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.181-182
    • /
    • 2015
  • In a power system with a high wind power penetration level, the output power of a wind power plant (WPP) might give negative impacts on the frequency control of a power system. This paper proposes a power smoothing scheme of a wind turbine generator (WTG) to reduce the frequency deviation. To do this, an additional control loop is used, the output of which depends on the frequency deviation. The gain of the additional loop is determined depending on the kinetic energy (KE) of a WTG; in the under frequency condition, the gain is set to be proportional to the releasable KE of a WTG; otherwise, it is set to the maximum value. The performance of the proposed scheme is investigated for 100-MW doubly-fed induction generator based WPP using an EMTP-RV simulator under various wind conditions. The results show that the proposed scheme successfully reduces the frequency deviation.

  • PDF

Effects of the Phase Noise in the Frequency Synthesizer on the SFH/M-NCFSK System (주파수 합성기의 위상 잡음이 SFH/M-NCFSK 시스템에 미치는 영향)

  • 손종원;이준서;유흥균;박진수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제14권7호
    • /
    • pp.685-691
    • /
    • 2003
  • This paper newly analyzes the effect of the phase noise in the frequency synthesizer on the performance of SFH/M-NCFSK system by standard frequency deviation(equation omitted) when noncoherent FSK demodulation of the square-law detector is considered. We derive the SER in the SFH system and analyze the effect of phase noise on the SFH/M-NCFSK system performance according to the hopping frequency spacing (1/T$\_$h/) and the variation of the standard frequency deviation (equation omitted). The required SNR is about 13.4 dB to meet Ps=10$\^$-3/ when the standard frequency deviation is about 4.0 Hz and the hopping frequency spacing (1/T$\_$h/) in the SFH/2-NCFSK system is 30. So, there is about 2.4 dB power penalty than the phase noise-free system. If the hopping frequency spacing 1/T$\_$h/ is under 30, the error floor may happen and SER considerably grows up. We show that the analytic results closely match with the simulation results.

Dynamic Characteristics of Laminated Rotor Core of Electric Motor Products (생산 전동기 로터 적층 코어의 동특성 조사)

  • Kim, Kwan-Young;Moon, Byung-Yun;Lee, Soo-Mok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • The dynamic characteristics of rotor shafts for electric motors were investigated through the modal tests. The natural frequencies and modal dampings in each manufacturing stage of rotor core assembly were analyzed from the frequency response functions fer all 6 motors of a product model. The deviation of the each individual modal feature was found dependent on the mode shapes as well as the rotor assembly stage. The core stacking itself is known to widen the deviation of modal properties but fellowing processes of rotor bar insertion and swaging are confirmed to reduce the deviation. Finally the equivalent diameter of core part was estimated from the comparison of measured and calculated results to include the stiffness of core part.

  • PDF

A comparison between digital algorithms for estimation of power system frequency (계통 주파수 추정을 위한 디지털 알고리즘 간의 비교)

  • Lee, B.H.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.276-277
    • /
    • 2006
  • Estimation of power system frequency is an important task because frequency deviation is a good indicator of the system abnormal operating conditions. The algorithms, curve fitting, technique using Taylor series, deviation of phasor angle of fundamental waveform using DFT (Discrete Fourier Transform) and Prony method, are tested under operation of the frequency relaying by using EMTP MODELS. The performance of methods is compared with the simulation results.

  • PDF