• Title/Summary/Keyword: Frequency Change

Search Result 4,393, Processing Time 0.032 seconds

A Study on the Optimal Load Shedding Method under Large Generator Outage (대전원 탈락사고시 최적부하 차단방법에 관한 연구)

  • 유현재;정재길
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.35-41
    • /
    • 1995
  • This paper proposes an adaptive methodology for setting of the underfrequency relays that is based on the initial rate of change of the frequency decline to protect for excess frequency decline of power system under large generator outage. The strategy of the load shedding is as follows : Let the load shedding of the first step occur when the frequency reaches 59.5 (Hz), and the load shedding power of this first and second step be one half of the total "Static Load Shed" value for any given disturbance size based on the initial rate of change of the frequency. As a results, it is verified that the use of the proposed method is more efficient than the conventional method in the characteristic of the frequency recovery. recovery.

  • PDF

Super-giant Magneto-Impedance Effect of a LC-resonator Using a Glass-Coated Amorphous Microwire

  • Lee, Heebok;Kim, Yong-Seok;Yu, Seong-Cho
    • Journal of Magnetics
    • /
    • v.7 no.4
    • /
    • pp.160-164
    • /
    • 2002
  • A new discovery of the super-giant magneto-impedance (SGMI) effect was found out in a LC-resonator consisted of a glass-coated amorphous $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire. The measurement was carried out at high frequency range from 100 MHz up to 1 GHz of an ac-current flowing along the wire and at varying axial dcmagnetic field in its range of $\pm$120 Oe. The wires, about 16${\mu}m$ in diameter, were fabricated by a glass-coated melt spinning technique. The shape of the impedance curves plotted vs. a dc-field is changing dramatically with the frequency. The phase angle was also strongly dependent on this field. The external dc-magnetic field changes the circumferential permeability as well as the penetration depth, both in turn change the impedance of the sample. The drastic increments of SGMI at high frequency can be understood in terms of the LC-resonance phenomena. The sudden change of the phase angle, as large as $180^{\circ}$ evidenced the occurrence of the resonance at a given intensity of the external dc-field. The maximum ratio of SGMI reached in the experiment by precise tuning frequency equals 450,000% at the frequency of around 551.9075 MHz.

The Diagnosis of Cooling Tower System (Cooling Tower System 진동 진단)

  • Lee, Sun-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1090-1094
    • /
    • 2007
  • The aim of this study is to estimate the cause of Cooling Tower vibration and eliminate the faults of fan with high vibration in spite of overhaul. The cause of high vibration was that the natural frequency of fan blade coincide with second blade pass frequency. To achieve reduction of Cooling Tower vibration, change motor speed from 1784rpm to 1714rpm, and then the vibration has reduced conspicuously.

  • PDF

Effects of Microcurrent Electrical Neuromuscular Stimulation of Auricular and Somatic Acupuncture Points on Experimental Pressure Threshold (외이경혈 미세전류신경근 자극과 체성경혈 미세전류신경근 자극이 압통역치에 미치는 효과)

  • Ko, Hyun-Chul;Cho, Won-Ho;Han, Seung-Soo
    • Physical Therapy Korea
    • /
    • v.4 no.2
    • /
    • pp.36-50
    • /
    • 1997
  • The purpose of this study was to compare the effects of high intensity, high frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points and low intensity, low frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points on experimental pressure threshold at the elbow according to the time. Fifty healthy adults, aged 19 to 26 years, were assigned randomly to one of five groups: 1) the high intensity, high frequency somatic group(n=10) received MENS to somatic acupuncture points, 2) the high intensity, high frequency auricular group(n=10) received MENS to auricular acupuncture points, 3) the low intensity, low frequency somatic group(n=10) received MENS to somatic acupuncture points, 4) the low intensity, low frequency somatic group(n=10) receive MENS to somatic acupuncture points, and 5) the placebo group(n=10) received placebo treatment and served as controls. Pressure threshold was measured before, after, 5 minutes, 10 minutes and 15 minutes. Pressure threshold has increased significantly(p<.05) in the high intensity, high frequency auricular group following treatment after 5 minutes, with no statistically significant differences in pressure threshold change scores among five groups, Only the high intensity, high frequency auricular group demonstrated statistically significant change score in pressure threshold following treatment after, 5 minutes, 10 minutes and 15 minutes after compared to the placebo group. The results indicated that MENS applied to the high intensity, high frequency auricular group increases pressure threshold.

  • PDF

A Study on the Elastic Property Change with Temperature in Si Materials for MEMS (MEMS용 Si 소재의 온도에 따른 탄성 특성 변화에 관한 연구)

  • Jung, Sung-Hoon;Lee, Se-Ho;Lee, Sung-Hun;Kwon, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.59-61
    • /
    • 2001
  • Electrostatically actuated test devices were designed to evaluate the elastic modulus of single crystalline Si (100) materials for MEMS device. Elastic modolus was calculated from resonant frequency by applying Rayleigh's energy method. Temperature effect on elastic properties was evaluated by detecting the resonant frequency change with increasing temperature to $600^{\circ}C$. The elastic modulus was decreased with heating and then increased with cooling, but specimen with thermal cycle showed a permanent change which is lower than the initial value. This phenomenon was explained by the change of interatomic force and the formation of $SiO_2$ layer on Si. The thickness of oxide layer was estimated by considering the change of mass and stiffness, and the formation of oxide layer was observed by the SEM photograph.

  • PDF

Posture Change Affects Indices of Pupil Size - Korean Males in Their Twenties

  • Lee, Jeung-Chan;Kim, Ji-Eun;Park, Kyung-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To determine the effect of posture change on autonomic activity and to investigate valid parameters to reflex the autonomic activity from time-series pupil size data, a posture-related experiment was performed with 15 subjects, which involved measuring their electrocardiograms and pupil sizes. The experimental procedure consisted of three-sequence postures-supine, sitting and upright-for 5 minutes each, with rest sessions between postures. The subjects were notified of the entire experimental procedure. The parameters of the subjects' heart rate variability showed significant differences between the postures (heart rate: 63-70-80 beat, normalized low frequency power: 28-50-75, normalized high frequency power: 72-49-25 and ratio: 0.5-1.2-4.4 in supine-sitting-upright position respectively) as did the parameters of their mean pupil sizes (41300-53900-53700 pixels respectively) and the major frequencies (the third trend: 0.23-0.2-0.18 Hz respectively) of their pupil size variability according to changes in their autonomic activities induced by posture change. The experiment thus proved that posture change affects autonomic activity and that such activity can be estimated by the parameters of pupil size as similar as heart rate variability.

An Empirical Analysis on Consumer Damage Cases of Clothing Products (의류제품의 소비자 피해 사례에 대한 실증분석)

  • Park, Younghee
    • Journal of Fashion Business
    • /
    • v.18 no.1
    • /
    • pp.149-163
    • /
    • 2014
  • The purpose of this study is to investigate and analyze the actual conditions of consumer damage occuring in the use of clothing products. The data used for analysis included 470 cases, which were deliberated by requesting consumer disputes deliberation at the consumer consultation room of Masan YWCA at the Kyeongsangnamdo Consumer Life Center belonging to the Kyeongnam provincial office. The disputes regarding the clothing products insisted that consumers suffered damage for the period from March, 2011 to June, 2013. The data processing was carried out by SPSS 14 and the statistics techniques used went through a cross tabulation analysis and ${\chi}^2$-test. The results are as follows. The difference in the analysis result of purchase path and material as to kinds of clothing products showed a significant difference. The damage types of clothing products were classified into five types: change of color, change of style, change of surface and touch, breakage of subsidiary materials, and others. The damaged clothing products showed a difference for damage frequency according to the items of clothing products; in particular, damage frequency for change of color appeared high. The damage contents of change of color were identified as metachromatism, discoloration and yellowing, stain occurrence, and decolorization. The damage responsibility for these clothing products appeared to be various as to clothing items, but was higher at dry cleaners and manufacturers.

Design and embodiment of low frequency system for myalgia treatment by variableness pulse mode (가변펄스 모드에 의한 Myalgia 치료를 위한 저주파 시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.1
    • /
    • pp.23-28
    • /
    • 2007
  • There are many modern's overwork. excessive drinking, carriage that give stress in muscle by smoking. Because time that sit long by carriage is much. if myalgia beats widower on muscle rheumatism or union formation inflammation, core ache, there is congealment and is painful. Muscle itself is no military register change and rheumatism change shows in areolation of muscle film or muscle nerve sheath etc. that union tissue's inflammation case is around the muscle. It is typical rain joint sex rheumatism. Can assume in case of made work that do not get used to extreme exercise or body perforce. Special quality of do waveform and supersonic waves stimulation processing plant which frequency that is established in research that do Iroin is continued without change is available embodiment according to patient's state variously by series mode through mode frequency waveform, 10 modes, 25 modes, 50 modes etc. Sample that can decide basis standard for supersonic waves through an experiment, low frequency treatment equipment standard for low frequency equipment. supersonic waves treatment equipment that float in city adjusting establishment naturally establish.

  • PDF

Validity for Classifying the Stages of Change among the Dietary Assessment Methods on Eating Fruits and Vegetables for American College Students

  • Chung, Sang-Jin;Sharon L. Hoerr;Ralph Levine;Won O. Song;Gayle Coleman
    • Journal of Community Nutrition
    • /
    • v.4 no.3
    • /
    • pp.143-150
    • /
    • 2002
  • The objective of this study is to establish outcome validity for three instruments that assess whether subjects met recommendations for daily servings of fruits and vegetables for“Stage of Change”research. A convenience sample of 294 college students was recruited from introductory nutrition classes at Michigan State University in the United States. To measure servings of fruits and vegetables, separately, three types of methods (self-rated intake, 24-hour recall and food frequency) were used in comparison to the servings from a three-day food record, the criterion used. The outcome validity was assessed based on whether or not at least two servings of fruits and three servings of vegetables were reported. Validity was assessed by sensitivity, to measure the ability to detect low intakes, and by specificity, to measure ability to detect adequate intakes. Cohen's kappa was used as well to examine the agreement between the three methods and a three-day food record. The results showed, for fruits, the 24-hour recall had the best agreement (recall 0.54, self-rated : 0.31, food frequency : 0.29) with a three-day food record for servings consumed by people in pre-action or post-action stages. Sensitivity for fruit was also best using a recall (0.81). For vegetables, however, all three methods had low agreement (food frequency : 0.27, recall : 0.21, self-rated : 0.17) with the results of the three-day food record. Self-rated intakes for vegetables had the best sensitivity (0.66) and the food frequency had the best specificity (0.73). Therefore, researcher can use the 24-hour recall method to identify people who consume inadequate servings of fruit. To detect adequate vegetable intake, the food frequency was best of the three methods. Accuracy may be improved by probing for vegetables in mixed dishes and on sandwiches. (J Community Nutrition 4(3): 143∼150, 2002)

Performance Analysis of OFDM-based Underwater Acoustic Communication System by Repeated Transmit Diversity Technique (반복 전송 다이버시티 기법에 따른 OFDM 기반 수중 음향 통신 시스템의 실해역 성능 분석)

  • Chae, Kwang-Young;Ko, Hak-Lim;Kim, Min-Sang;Cho, Yong-Ho;Im, Tae-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1434-1442
    • /
    • 2019
  • In this paper, the channel change was continuously measured for 24 hours from July 5, 2017 on the coast near Deokjeok-do, Incheon. The underwater channel has various channel environment characteristics as the change in the time axis and the change in the frequency axis occurs in real time, and the underwater communication performance decreases due to the multipath fading and the Doppler effect. Therefore, in this study, we performed the OFDM system performance analysis in the underwater channel environment by applying the repetitive transmission diversity scheme in the time and frequency domain to improve the communication performance in the real-world underwater communication environment. Using the collected data, we compared the channel environment in the time and frequency domain and analyzed the BER performance according to the pilot spacing and the number of repetitive transmissions in the time and frequency axis.