• Title/Summary/Keyword: Frequency

Search Result 66,280, Processing Time 0.067 seconds

Sidelobe Suppression Enhancement of Radiofrequency Photonic Filters via Time-to-frequency Mapping

  • Song, Min-Hyup
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.449-452
    • /
    • 2014
  • We present a multi-tap microwave photonic filter with high selectivity through applying time-to-frequency mapping and optical frequency comb shaping techniques. When arranged in the time-to-frequency mapping stage, by a Fourier transform, the deviation of the optical taps to the target profile is significantly reduced while maintaining the apodization profile, resulting in high sidelobe suppression in the filters. By applying a simple time-to-frequency mapping stage to the conventional optical frequency combs, we demonstrate a substantially enhanced (>10dB) sidelobe suppression, resulting in filter lineshapes exhibiting a significantly high (>40dB) main lobe to sidelobe suppression ratio. These results highlight the potential of the technique for implementation in various passband filters with high sidelobe suppression.

Frequency Analysis of EMG Signals using Power Spectral Density (전력 스펙트럼 밀도를 이용한 근전도 신호의 주파수 해석)

  • 박상희;변윤식
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.19-30
    • /
    • 1985
  • This paper describes the EMG signals in frequency domain using power spectral density, The changes in the moan frequency can represent the energy distribution which results from changing in load before and during fatigue. Most of EMG signal power spectrum is located between 10 and 200Hz. Shifts of the high-energy regions of the power spectra can be inferred from the changes in the mean frequency. If the load is increased without fatigue-ocurring, the high frequency regions have more energy than the low frequency regions. And if load is increased during fatigue, the low frequency regions have more energy than the high frequency regions.

  • PDF

Performance Analysis of a Residual Frequency Estimator for Weak AGPS Signals in Frequency Domain (약 신호 환경의 AGPS를 위한 잔여주파수 추정기의 주파수 영역 성능 분석)

  • Park, Ji-Hee;Im, Hyun-Ja;Song, Seung-Hun;Sung, Tae-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.7
    • /
    • pp.720-725
    • /
    • 2010
  • In AGPS method, user position can be obtained even in the shadow region by improving signal sensitivity. A hybrid long integration scheme employing both coherent and non-coherent integration method is commonly used in AGPS receivers. Because coherent loss increases as residual frequency become large, residual frequency should be minimized to maximize coherent integration gain. This paper presents performance analysis of residual frequency estimator using FFT in fine-time assistance AGPS method. Considering the hardware complexity and the estimation accuracy, optimal length of FFT is proposed for GPS L1 C/A signal. Signal sensitivity for estimating the residual frequency is also analysed. By field experimental results, it is found that the residual frequency can be successfully estimated using 1 second snap-shot data when GPS signal strength is larger than -150 dBm and its RMS error is 3Hz.

Development of Dynamic Frequency Monitoring Software for Wide-Area Protection Relaying Intelligence (광역 보호계전 지능화를 위한 동적 주파수 모니터링 S/W 개발)

  • Kim, Yoon-Sang;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.174-179
    • /
    • 2012
  • The social and economic level of damages might be highly increased in the case of wide-area black-outages, because of heavy dependence of electricity. Therefore, the development of a wide-area protection relay intelligence techniques is required to prevent massive power outages and minimize the impact strength at failure. The frequency monitoring and prediction for wide-area protection relaying intelligence has been considered as an important technology. In this paper, a network-based frequency monitoring system developed for wide-area protection relay intelligence is presented. In addition, conventional techniques for frequency estimation are compared, and a method for advanced frequency estimation and measurement to improve the precision is proposed. Finally, an integrated monitoring system called K-FNET(Korea-Frequency Monitoring Network) is implemented based on the GPS and various energy monitoring cases are studied.

Estimation Technique of Frequency using FIR Filter in the Power System (FIR 필터를 이용한 전력계통의 주파수 추정기법)

  • 남시복;박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Research on In-band Spurious Evasion Techniques of Hybrid Frequency Synthesizer

  • Kim, Seung-Woo;Yoo, Woo-Sung
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.176-185
    • /
    • 2015
  • The study aims to a design hybrid frequency synthesizer in spectrum analyzer and to propose new techniques designed for evasion of in-band spurious. The study focuses on calculating the exact location of multiple phase locked loop of hybrid frequency synthesizer and spurious of direct digital synthesizer to evade in-band spurious outside of frequency range that the user wants to see and thereby simulating technique to improve input related spurious of spectrum analyzer for algorithm. The proposed technique is designed to calculate spurious evasion algorithm in central processing system when in-band spurious arises, and to move output frequency of DDS(direct digital synthesizer) into the place where no in-band spurious exists thereby improving performance of frequency synthesizer. The study used simulation and result representation to prove the effectiveness of the proposed technique.

Frequency-dependent electrical parameters of soils as a function of the moisture content (수분함유량에 따른 토양의 전기적 파라미터의 주파수의존성)

  • Lee, Bok-Hee;Kim, Ki-Bok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.68-74
    • /
    • 2014
  • The electrical parameters of soils are highly dependent on the various factors such as types of soil, chemical compositions, moisture content, temperature, frequency, and so on. The analysis of soil parameters is of fundamental importance in design of grounding systems. In this paper, we present the experimental results of frequency-dependent impedance, resistivity, permittivity of soils as functions of types of soil and moisture content. The impedance and resistivity of soils are decreased as the moisture content and the frequency increase. In particular, the variation of the soil resistivity with the frequency is pronounced in the conditions of high resistivity and low moisture content. On the contrary, the permittivity of soils are sharply decreased with increasing the frequency below 10kHz and the frequency-dependent permittivity of soils are highly changed in the conditions of high moisture and low resistivity.

A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

A Study on Data Transmission Using Dual Frequency (Dual 주파수를 이용한 Data 전송에 관한 연구)

  • Lee, Jin;Park, Sung Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.398-402
    • /
    • 2018
  • The following conclusions were obtained after analyzing the data transmission characteristics using two frequencies and studying a system that selects data with a good reception frequency as a priority data. Data transmission and reception using two frequencies were measured at -41 to -51 dBm when the frequency was normal, and data transmitted at 900 MHz was selected as priority data. When priority frequency failure occurred, the frequency reception data of the next rank was automatically adopted, and when the frequency of the next rank was disturbed, the priority frequency search was performed again. The above results show that the use of two frequencies enables more stable data transmission and transmission, and further studies should be continued to expand the transmission and reception distances.

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.