• 제목/요약/키워드: Freezing module

검색결과 11건 처리시간 0.023초

제주지역 도로결빙 예측에 관한 연구 (A Study on Prediction of Road Freezing in Jeju)

  • 이영미;오상율;이수정
    • 한국환경과학회지
    • /
    • 제27권7호
    • /
    • pp.531-541
    • /
    • 2018
  • Road freezing caused by snowfall during wintertime causes traffic congestion and many accidents. To prevent such problems, we developed, in this study, a system to predict road freezing based on weather forecast data and the freezing generation modules. The weather forecast data were obtained from a high-resolution model with 1 km resolution for Jeju Island from 00:00 KST on December 1, 2017, to 23:00 KST on February 28, 2018. The results of the weather forecast data show that index of agreement (IOA) temperature was higher than 0.85 at all points, and that for wind speed was higher than 0.7 except in Seogwipo city. In order to evaluate the results of the freezing predictions, we used model evaluation metrics obtained from a confusion matrix. These metrics revealed that, the Imacho module showed good performance in precision and accuracy and that the Karlsson module showed good performance in specificity and FP rate. In particular, Cohen's kappa value was shown to be excellent for both modules, demonstrating that the algorithm is reliable. The superiority of both the modules shows that the new system can prevent traffic problems related to road freezing in the Jeju area during wintertime.

A Brief Review on Variables and Test Priorities of Photovoltaic Module Life Expectancy

  • Padi, Siva Parvathi;Chowdhury, Sanchari;Zahid, Muhammad Aleem;Kim, Jaeun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • 제9권2호
    • /
    • pp.36-44
    • /
    • 2021
  • To endorse the reliability and durability of the solar photovoltaic (PV) device several tests were conducted before exposing to the outdoor field in a non-ideal condition. The PV module has high probability that intend to perform adequately for 30 years under operating conditions. To evaluate the long term performance of the PV module in diversified terrestrial conditions, one should use the outdoor performance data. However, no one wants to wait for 25 years to determine the module reliability. The accelerating stress tests performing in the laboratory by mimicking different field conditions are thus important to understand the performance of a PV module. In this review, we will discuss briefly about different accelerating stress types, levels and prioritization that are used to evaluate the PV module reliability and durability before using them in real field.

무창 기공형 태양열 공기 난방 모듈 성능 모니터링 연구 (Performance Monitoring Study of Unglazed Transpired Solar Air Heating Module)

  • 강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.67-72
    • /
    • 2002
  • Solar Air Systems (SAS) have unique advantages for space heating and tempering ventilation air. Air, unlike water, needs no protection against freezing nor are leaks damaging to the building structure or its contents. In contrast to glazed collector, unglazed steel solar collector may have higher efficiencies over glazed flat collector due to the absence of the glass. Therefore, the monitoring of SAS is so important to evaluate actual performance of SAS for right applications. This study is to provide a testing method with a movable test cell developed in KIER to evaluate the thermal performance of SAS based on international standard method ASHRAE 93-86, "Method of Testing to Determine the Thermal Performance of Solar Collectors". The monitoring tool used advanced technique LabVIEW 6i with portable notebook computer. Sample results have been obtained to access the performance of a reference and a target SAS module. The process and tool introduced here could be used to provide a performance verification data for future implementation study applications.

Identification and functional analysis of COLD-signaling-related genes in Panax ginseng

  • Jeongeui Hong;Hojin Ryu
    • Journal of Plant Biotechnology
    • /
    • 제50권
    • /
    • pp.225-231
    • /
    • 2023
  • Cold stress is one of the most vulnerable environmental stresses that affect plant growth and crop yields. With the recent advancements in genetic approaches using Arabidopsis and other model systems, genes involved in cold-stress response have been identified and the key cold signaling factors have been characterized. Exposure to low-temperature stress triggers the activation of a set of genes known as cold regulatory (COR) genes. This activation process plays a crucial role in enhancing the resistance of plants to cold and freezing stress. The inducer of the C-repeatbinding factor (CBF) expression 1-CBF module (ICE1-CBF module) is a key cold signaling pathway regulator that enhances the expression of downstream COR genes; however, this signaling module in Panax ginseng remains elusive. Here, we identified cold-signaling-related genes, PgCBF1, PgCBF3, and PgICE1 and conducted functional genomic analysis with a heterologous system. We confirmed that the overexpression of cold- PgCBF3 in the cbf1/2/3 triple Arabidopsis mutant compensated for the cold stress-induced deficiency of COR15A and salt-stress tolerance. In addition, nuclearlocalized PgICE1 has evolutionarily conserved phosphorylation sites that are modulated by brassinsteroid insensitive 2 (PgBIN2) and sucrose non-fermenting 1 (SNF1)-related protein kinase 3 (PgSnRK3), with which it physically interacted in a yeast two-hybrid assay. Overall, our data reveal that the regulators identified in our study, PgICE1 and PgCBFs, are evolutionarily conserved in the P. ginseng genome and are functionally involved in cold and abiotic stress responses.

동토 플랜트 유체기계 구조물 설치를 위한 PET 골재적용 말뚝의 주면작용 수평력 평가 (Evaluation of Horizontal Force on Pile Shaft Surrounded by Vertical PET Aggregate Layer for Fluid Machinery Structure Installation in Cold Region's Plant)

  • 지수빈;장성민;황순갑;이기철;김동욱
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.43-47
    • /
    • 2016
  • Pile foundations constructed on extremely cold regions cause serviceability problems of superstructures from repeated actions of ground freezing and thawing. Oil sand module plants are mainly constructed on seasonal frozen ground. Due to the freezing and thawing actions of grounds, vertical movements of piles have been observed. To solve these erratic pile movement problems, thin vertical layer of PET aggregates is installed around the pile shaft to prevent potential unfavorable pile movements. There is no known method to calculate "thin PET aggregate layer" -surrounded pile shaft resistance (capacity) against vertical loads; therefore, this experimental research is conducted. Specifically, in this study, horizontal (normal) pressures on pile shaft were assessed varying PET aggregate layer thickness based on the experiment.

A New Protocol for Effective Cryopreservation of Human Embryonic Stem Cells by a Minimum Volume Cooling Method

  • Kim, Eun-Young;Lee, Keum-Sil;Shin, Hyun-Ah;Park, Sae-Young;Yoon, Ji-Yeon;Kil, Kwang-Soo;Lee, Young-Jae;Kim, Nam-Hyung;Chung, Kil-Saeng
    • 한국발생생물학회:학술대회논문집
    • /
    • 한국발생생물학회 2003년도 제3회 국제심포지움 및 학술대회
    • /
    • pp.98-98
    • /
    • 2003
  • Recently, human embryonic stem (hES) cells have become very important resources for ES cell basic research, cell replacement therapy, and other medical applications; thus, efficient cryopreservation methods for these cells are needed. This study examined whether a newly developed minimum volume cooling (MVC) vitrification method, which was tested through cryopreservation of sensitive bovine oocytes, can be used for freezing hES cells. Feeder-free cultured hES cell (MB03) colonies were mechanically dissected into several small clumps following enzymatic treatment. We compared the freezing efficiency of a slow-cooling method using a cryo-module (0.4-0.6C/min, 20-30 clumps/vial) and MVC vitrification using a modified 0.5-ml French mini-straw designated as a MVC straw (>$20,000{\circ}C$/min, 10 clumps/straw) After thawing, in vitro survival of hES cell clumps was higher for MVC-vitrified cells (80.8%, 97/120) than for slow-cooled cells (38.2%, 39/102). Further, the proliferation rate of surviving MVC-vitrified cells was similar to that of control hES cells from 2 weeks after thawing. In addition, vitrified-thawed hES cells demonstrated a normal karyotype, were positively immunostained for surface marker antibodies (AP, SSEA-4 and TRA-1-60) and the Oct-4 antibody, and could differentiate into all three embryonic germ layer cells in vitro. This result demonstrates that hES cell clumps can be successfully cryopreserved by a newly developed MVC vitrification method without loss of human cell characteristics.

  • PDF

단일추진제 로켓 엔진 어셈블리를 위한 우주 공간에서의 과실 방지 설계 (Faultproof Design in Space for Monopropellant Rocket Engine Assembly)

  • 한조영;김정수
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1377-1384
    • /
    • 2003
  • An analysis has been performed for active thermal control of the KOMPSAT monopropellant rocket engine assembly, i.e., dual thruster module(DTM). The main efforts of this work have been directed at determining proper heater sizes for propellant valves and catalyst beds necessary to maintain their temperatures within specified temperature ranges under KOMPSAT environment and operational conditions. The TAS incorporated with TRASYS thermal radiation analyzer was used to establish a complete heat transfer model which allows to predict the DTM temperature as a function of time. The thermal analysis has been performed in transient mode to verify the appropriate power for catalyst bed heaters necessary to increase catalyst bed temperature to the required value within a specified period of time. Similar analysis has been executed to validate the heater power for the thermostatically controlled primary and redundant heater circuits used to prevent hydrazine freezing, i.e., single fault. Moreover the effect of the radiative property of thermal control coating of heat shield was examined. Thruster firing condition was also simulated for the heat soakback condition. As a consequence, all thermal analysis results for DTM satisfactorily met the thermal requirements for the KOMPSAT DTM under the worst case average voltage, i.e. 25 volt.

캐나다 오일샌드 플랜트 온도 조건을 고려한 구조물 모니터링 통신 모듈 적용성에 관한 연구 (A Study of Structure Monitoring Applicability of ZigBee Module through Oil Sand Plant Temperature around Canada)

  • 양희권;이찬길;이방용;박근보
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.37-42
    • /
    • 2016
  • The demand for wireless technology in plant structure has recently been increasing due to several advantages such as installation cost reduction, easy placement, easy extension and aesthetic benefits. Among the many wireless technologies, ZigBee is one of the most useful for plant structure; a wireless plant networking system can be configured using ZigBee alone. This research proposes a ZigBee to use for extreme cold region and thereby enable integration of wired and wireless plant monitoring systems. In this study, in order to assess the performance of ZigBee measured data by thermocouple were examined based on the results from laboratory tests between existing ZigBee and developed ZigBee. From the experiment results, performance of developed ZigBee in harsh environment can be increased well.

열관과 상변화물질을 일체형으로 병렬 배열한 위성용 열제어 부품 연구 (Study on the Satellite Thermal Control Hardware Composed of Two Parallel Channels Working for Heat Pipe and Phase Change Material)

  • 김택영;현범석;이장준;이주훈
    • 한국항공우주학회지
    • /
    • 제38권11호
    • /
    • pp.1087-1093
    • /
    • 2010
  • 열관(HP)과 상변화물질(PCM)을 병렬로 배열한 일체형 위성 열제어 H/W를 제안하였다. HP-PCM 모듈은 제한적인 의미에서 일종의 off-the-shelf 부품으로써, PCM을 위한 별도의 열설계와 형상설계 등을 수행하지 않더라도 기존에 사용하고 있는 HP처럼 크기나 개수 등만을 설계함으로써 온도제어를 달성할 수 있도록 하였다. 주기적인 발열이 있는 부품의 온도제어를 위하여, 제안한 HP-PCM 모듈이 적용된 위성 방열판을 설계하고 상세모델을 수립하여 수치해석을 수행하였다. 각각 PCM이 없는 경우와 PCM을 장입한 경우에 대하여 수치해석을 수행하였으며, 등가평균값의 주기적인 변화에 대한 비교분석을 통하여 PCM의 축열과 방열에 의한 열분산이 매우 효과적임을 확인하였다. HP가 작동하지 않는 경우에 대한 수치해석을 통하여 열전도도가 작은 PCM의 사용한계를 제안한 HP-PCM 모듈을 이용하여 극복할 수 있음을 확인하였다.

Effect of freezing on electrical properties and quality of thawed chicken breast meat

  • Wei, Ran;Wang, Peng;Han, Minyi;Chen, Tianhao;Xu, Xinglian;Zhou, Guanghong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제30권4호
    • /
    • pp.569-575
    • /
    • 2017
  • Objective: The objective of this research was to study the electrical properties and quality of frozen-thawed chicken breast meat and to investigate the relationship between these parameters at different times of frozen storage. Methods: Thawed samples of chicken breast muscles were evaluated after being kept in frozen storage at $-18^{\circ}C$ for different periods of time (1, 2, 3, 4, 5, 6, 7, and 8 months). Results: The results showed that water-holding capacity (WHC) and protein solubility decreased while thiobarbituric acid-reactive substances content increased with increasing storage time. The impedance module of samples decreased during 8-month frozen storage. Pearson correlation coefficients showed that the impedance change ratio (Q value) was significantly (p<0.05) related to pH, color, WHC, lipid oxidation and protein solubility, indicating a good relationship between the electrical properties and qualities of frozen-thawed chicken breast meat. Conclusion: Impedance measurement has a potential to assess the quality of frozen chicken meat combining with quality indices.