• 제목/요약/키워드: Freezing damage

검색결과 285건 처리시간 0.021초

액상형 규산질계 침투성 방수재의 성능평가에 관한 연구 (A Study on a Performance evaluation for Quality Liguid Siliceous of Waterproof agent)

  • 강효진;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs, to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

액상형 규산질계 침투성 방수재의 성능평가에 관한 연구 (A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent)

  • 강효진;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liquid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

Evaluation criteria for freezing and thawing of tunnel concrete lining according to theoretical and experimental analysis

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun;Lattner, Tim
    • Geomechanics and Engineering
    • /
    • 제29권3호
    • /
    • pp.349-357
    • /
    • 2022
  • Abnormal climate events are occurring frequently around the world. In particular, cold waves and heavy snow lead to damage and deterioration of facilities, which can cause loss of life or property damage, such as shortening the lifespan of facilities. Therefore, it is very important to prepare an appropriate maintenance system and to establish a strategy to cope with abnormal weather conditions. In this study, laboratory freezing experiments were performed to analyze the freeze-thaw characteristics affecting the tunnel concrete lining, and heat flow analysis was carried out based on the test results. Based on these experimental and theoretical analysis results, quantitative freeze-thaw evaluation criteria for tunnel concrete linings were proposed.

한랭지에 있어서 고류동콘크리트의 동해에 관한 연구 (Study on the Frost Damage of Self-Compacting Concrete in Cold Weather Regions)

  • 고경택;이장화;한상묵;장일영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.763-766
    • /
    • 1999
  • The objective of this study was to investigate the influence of low temperature curing on resistance of freezing and thawing of self-compacting concrete placed in cold weather regions. The experimental study results indicated that the self-compacting concrete incorporating ground granulated blast-furnace slag showed good resistance to freezing and thawing, and the self-compacting concrete cellulose viscous agent had relatively poor resistance to freezing and thawing.

  • PDF

Bacillus licheniformis 균주를 혼입한 모르타르의 동결융해 저항성 평가 (An Evaluation on Freezing and Thawing Resistance of Mortars with Bacillus licheniformis)

  • 황지원;윤현섭;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.237-238
    • /
    • 2022
  • This study used Bacillus licheniformis generating glycocalyx as a provective membrane to enhance the salt-damage resistance of cement mortars. The mortar specimens with Bacillus licheniformis exhibited a comparable compressive strength development and 1.1~1.3 times higher dynamic modulus of elasticity under 300 freezing and thawing cycyles when compared with the counterpart control mortar.

  • PDF

전기적 열선의 발화 및 화재 위험성에 관한 연구 (A Study on Ignition and Fire Risks of Electric Heat Wire)

  • 민세홍;송병준
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

강원지역의 2010년 복숭아 동해 (Regional Distribution of Peach Freezing Damage and Chilling Days in 2010 in Gangwon Province)

  • 서영호;박영식;조병욱;강안석;정병찬;정영상
    • 한국농림기상학회지
    • /
    • 제12권4호
    • /
    • pp.225-231
    • /
    • 2010
  • 강원도 주요 복숭아 재배지의 2010년 1월 7일의 일 최저기온 분포는 $-18{\sim}-29^{\circ}C$로서, 평년보다 $10^{\circ}C$ 이상 낮았으며 복숭아의 동해온도로 설정된 $-18^{\circ}C$보다 낮았다. 이로 인한 저온 피해 면적은 원주 144ha, 춘천 89ha, 영월 33ha, 횡성 22ha, 양구 17ha, 홍천 16ha 등이었다. 금후 강원 지역의 복숭아 동해에 대한 대책을 수립하는 데 기초 자료를 제공하고자 실제 동해 면적율과 휴면심도를 바탕으로 한 동해위험지수를 비교하였다. 자동기상측정장치가 설치된 지역의 일 최고기온과 일 최저기온, 기준온도를 바탕으로 계산한 장호원황도의 휴면심도는 -62 ~ -90였다. 휴면심도와 일 최저기온으로부터 계산된 동해위험지수는 51% 이상이었고, 이 동해위험지수는 실제 피해 면적 비율과 통계적으로 유의한 선형 관계를 나타내었다. 장호원황도의 휴면심도를 바탕으로 한 동해위험지수로 정확한 저온 피해 예측에는 어느 정도 한계가 있으나, 과수농가에서 복숭아의 동해를 대비하는 데 유용하게 활용할 수 있을 것으로 판단된다.

Effect of Freezing on Proteins and Protein Profiles of Sperm Membrane Extracts and Seminal Plasma of Buffalo Bulls

  • Dhanju, C.K.;Cheema, R.S.;Kaur, S.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권12호
    • /
    • pp.1678-1682
    • /
    • 2001
  • The total proteins were estimated in both deoxycholate (DOC)-extract of sperm membrane and seminal plasma of chilled as well as frozen semen obtained from five Murrah buffalo bulls. Proteins were further characterized by polyacrylamide gel electrophoresis (PAGE) in three bulls. The protein content of sperm membrane extract (SME) and that of seminal plasma (SP) decreased gradually with increase in freezing period from 6 to 24 mo when compared with the values observed in freshly chilled semen in all bulls. The total decrease in protein content of SME and SP varied from 30-40% and 28-59% respectively during 6-24 mo of freezing. The number of glycoproteins/proteins (GP/P) in SME varied from 4-8 in freshly-chilled semen of all bulls and reduced to 2-4 after 24 mo of freezing. In SP, the number of proteins varied from 6-10 in freshly chilled semen of all bulls and reduced to 3-8 after 24 mo of freezing. Some of the proteins in SME and SP disappeared, others got altered and appeared with change in molecular weight after different freezing times. These studies reveal that alterations in the sperm membrane proteins may be responsible for damage to their membrane during freezing and thus lowering their fertilizability.

전복의 동결에 관한 연구 2) 동결에 의한 전복조직의 변화 (STUDIES ON FREEZING OF THE ABALONE 2. Histological Changes by Freezing)

  • 송대진
    • 한국수산과학회지
    • /
    • 제11권2호
    • /
    • pp.91-95
    • /
    • 1978
  • 세가지의 동결방법(air blast, semi air blast, still air freezing)으로 전복을 동결하여 $-20^{\circ}C$ 냉장고에서 3개월간 저장하고 동경방법의 처리에 따른 조직적인 변화를 생전복과 비교하여 다음과 같은 결과를 얻었다. 1. 생 전복의 조직구조는 소라의 그것과 비슷하였다. 2. 동결에 의한 근세포의 파괴는 없었다. 3. 동결방법의 차에서 오는 조직변화의 차이는 거의 없으며, 미세 빙결정이 많이 생겼다. 4. 동결에 의한 근조직 피해는 일반 어류보다 적었다.

  • PDF

도로 포장체에서 동상에 대한 지하수위 영향 평가 (Evaluation of Ground Water Level Effect on Frost Heaving in Road Pavements)

  • 권기철;이재환
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.47-56
    • /
    • 2013
  • PURPOSES: This study is to evaluate a ground water level effect on frost heaving in road pavements. METHODS: The effects of water table on frost heaving in pavement systems were evaluated from the mechanical analysis using FROST program. The input parameters and boundary conditions were determined by considering climates, pavement sections, and material properties specially subgrade soil types in Korea. RESULTS: When the water table located above the freezing depth, amount of frost heaving caused by freezing the water in pavement itself was big enough to damage in pavement system, although pavement system consists of fully non-frost-susceptible materials with sufficient thickness of anti-freezing layer. The amount of frost heaving was decreased rapidly with increasing the distance between the water table and freezing depth. CONCLUSIONS: It was concluded that there is no engineering problems related with frost heaving in practical sense when the distance between freezing depth and water table is over 1.5m for having subgrade soils less than 50% of #200 sieve passing to meet specification on quality control in Korea.