• Title/Summary/Keyword: Freezing chamber

검색결과 51건 처리시간 0.032초

냉매분사식 팽창장치를 적용한 냉동기의 특성에 관한 연구 (A Study on the Characteristics of the Refrigerator Using a Refrigerant Injection Type Expansion Device)

  • 조병옥
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.925-931
    • /
    • 2000
  • Refrigerating ability of vapor compression refrigerator is decided by the harmonic work of it's components such as compressor, condenser, evaporator, expansion device, and so on. In this study, choosing refrigerant injectors as a new one of expansion device, temperature change of the cold room, ice freezing ability, and power consumption on flowrate of injector and refrigerant charging condition are evaluated experimentally. As the results of this study, it is verified that the spray injection type refrigeration system has some merits according to the flowrate and spray pattern of injector and charging quantum of refrigerant. And there are some design factors such as spray pattern and shape of spray chamber to utilize and fabricate this refrigerant injection type refrigerator.

  • PDF

제주흑우 정액 동결을 위한 AndreoMed와 Triladyl 희석제의 동결성 비교 (Comparison of AndroMed and Triladyl Extender for Freezing of Jeju Native Black Bull Semen)

  • 조상래;조인철;한상현;강태영;조원모;채현석;김남영;박용상;강용준;김영훈;고응규;김현종;고문석
    • Reproductive and Developmental Biology
    • /
    • 제37권3호
    • /
    • pp.155-159
    • /
    • 2013
  • 본 연구는 제주흑우의 정액의 동결과 보존기술 개발을 위해 AndroMed와 Trialdyl를 사용하여 보다 우수한 희석제와 우수 종모우 선정을 위해 실시되었다. 종모우 1번부터 4번까지 개체 정자의 성상비교에서 수정능 획득과 첨체반응의 비율은 36.8%, 26.8%, 37.8% 그리고 38%의 결과를 나타내었다. 2번 개체 정자에서 수정능 획득과 첨체반응의 비율이 유의적으로(p<0.05) 낮은 결과를 보였다. 제주흑우 정액을 동결하기 전 정자의 생존율은 약 $93.27{\pm}1.62$, 동결 융해 후 생존율은 $73.34{\pm}3.27%$로 나타나 동결전 정액의 생존율이 유의적으로(p<0.05) 높은 결과를 나타내었으나, 사멸 정자의 비율은 약 $7.35{\pm}2.63%$$13.71{\pm}2.85%$의 결과를 나타내었다. 그리고 $Triladyl^{(R)}$ 동해 방지제를 사용하였을 때, 정자의 운동성은 $72.86{\pm}2.83%$, $AndorMed^{(R)}$를 사용하였을 때 운동성은 $81.47{\pm}2.48%$$AndorMed^{(R)}$ 동해방지제를 사용하였을 때 운동성이 다소 높은 경향을 보였으나, 유의적인 차이는 나타나지 않았다. 마찬가지로 정자의 사멸율에서도 $Triladyl^{(R)}$ 동해 방지제는 $18.41{\pm}3.42%$, $AndorMed^{(R)}$ 동해방지제는 $17.26{\pm}4.25%$의 결과를 보여 AndroMed를 사용한 동해방지제가 정자의 생존율을 향상시키는 것으로 나타났다. 결론적으로 제주흑우 정액의 동결 보존을 위해 보다 향상된 동결보호제 선정과 동결보존 기술 개발이 필요할 것으로 사료된다.

온도변화에 따른 모래-실트 혼합토의 전기비저항 특성변화 (Variation of Electrical Resistivity Characteristics in Sand-Silt Mixtures due to Temperature Change)

  • 박정희;서선영;홍승서;김영석;이종섭
    • 한국지반환경공학회 논문집
    • /
    • 제13권10호
    • /
    • pp.25-32
    • /
    • 2012
  • 전기비저항은 이온의 이동성에 의존하며 전기비저항의 활용도는 지하공동, 단층조사, 지하오염도 측정 등 다양한 지반조사 분야에서 증가하고 있다. 본 연구의 목적은 흙의 온도변화에 의한 전기비저항의 변화를 파악하는 것이다. 모래와 실트가 혼합된 시료를 동결시키기 위해 나일론 셀을 제작하였으며 시료의 온도를 변화시키기 위해 시료를 냉동고에 고정하였다. 온도변화에 따른 시료의 전기저항을 측정하기 위해 네 개의 전극을 정사각형 배열로 셀의 옆면에 설치하였다. 시료의 온도가 $20^{\circ}C$에서 $-10^{\circ}C$까지 변화하는 동안 옴의 범칙을 이용하여 포화도가 다른 각 시료(0%, 5%, 10%, 15%, 20%, 40%, 60%, 100%)의 전기저항을 측정하였으며 측정된 전기저항은 보정과정을 거쳐 전기비저항으로 환산되었다. 실험결과, 실험 초기 $20^{\circ}C$에서는 시료의 포화도가 증가할수록 전기비저항은 감소하였다. 상온에서 온도가 감소함에 따라 전기비저항은 서서히 증가하였으며, 본 연구에서 사용된 시료의 경우 포화도가 15% 이상인 시료들의 전기비저항은 $0^{\circ}C$ 근처에서 급격히 증가하였다. 또한, 동결된 시료의 전기비저항은 포화도와 관계없이 매우 크게 나타났다. 본 연구는 흙의 온도변화와 동결에 따른 전기비저항의 기초적인 정보를 제공하며 동결 깊이 추정과 같은 지반조사 시 전기비저항은 효과적인 방법이 될 수 있음을 보여준다.

캐나다 오일샌드 플랜트 온도 조건을 고려한 구조물 모니터링 통신 모듈 적용성에 관한 연구 (A Study of Structure Monitoring Applicability of ZigBee Module through Oil Sand Plant Temperature around Canada)

  • 양희권;이찬길;이방용;박근보
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.37-42
    • /
    • 2016
  • The demand for wireless technology in plant structure has recently been increasing due to several advantages such as installation cost reduction, easy placement, easy extension and aesthetic benefits. Among the many wireless technologies, ZigBee is one of the most useful for plant structure; a wireless plant networking system can be configured using ZigBee alone. This research proposes a ZigBee to use for extreme cold region and thereby enable integration of wired and wireless plant monitoring systems. In this study, in order to assess the performance of ZigBee measured data by thermocouple were examined based on the results from laboratory tests between existing ZigBee and developed ZigBee. From the experiment results, performance of developed ZigBee in harsh environment can be increased well.

뇌졸중후 뇌위축에 대한 조경론적 접근 (Role of $17{\beta}$- Estradiol on Brain Atrophy Following Cerebral Infarction)

  • 윤상협;이종수
    • 대한한의학회지
    • /
    • 제21권4호
    • /
    • pp.9-15
    • /
    • 2000
  • Objective : The aim of this study was to investigate the neuroprotection effect of estrogen on brain atrophy following cerebral infarction. Method : All animals in this study were classified into 4 groups; ovariectomy group (OVXgroup), cerebral infarction group (INF group), combination ovariectomy and cerebral infarction group (OVX + INF group), and naturally intact group for control data (NOR group). Cerebral infarction was made by Chen's method with some modification. Ovariectomy was performed by Wayforth's method. Experimental data for each group was collected at 15 days, month, 3 months, and 6 months after starting observation. Serum $17{\beta}-estradiol(E2)$ was determined by radioimmunoassay. Brain volume was measured and calculated with image analysis. Each brain was sliced at intervals of 2mm in chamber after 30 min of freezing in refregerater. Cerebral volume was obtained by sum of volume of each slice level, which was mean $area{\;}{\times}{\;}2mm$. Results : Cerebral ischemia was found to decrease the serum concentration of $17{\beta}-{\;}estradiol(E2)$ and to inhibit the physiologically conpensatary function of the ovariectomized rats. Also we found that deprivation of estrogen have resulted in more severe cerebral atrophy followed by cerebral infarction. Conclusion : It is suggested that estrogen has a neuroprotection effect on cerebral atrophy following cerebral infarction.

  • PDF

Changes in the quality of pork loin after short-term (ten-day) storage in a supercooling refrigerator

  • Park, Chun Ho;Park, Hye Sook;Yoon, Kyungah;Choe, Jeehwan
    • Journal of Animal Science and Technology
    • /
    • 제63권4호
    • /
    • pp.884-891
    • /
    • 2021
  • The study aimed to evaluate pork loin quality after short-term (ten-day) storage in a supercooling refrigerator. Pork loin samples were stored for 10 days in a traditional refrigerator (control) and a commercially available supercooling refrigerator (SC). Pork quality measurements included meat pH, meat color, water holding capacity (drip loss and cooking loss), tenderness (hardness), and a sensory evaluation. Temperature changes of 0.45 ± 0.2℃ and 0.02 ± 0.25℃ occurred in the control and the SC, respectively, during 10 days of storage. The temperature in the SC chamber did not remain below freezing point, failing to meet expectations. Regarding the pork quality measurements, only the drip losses in the control and the SC were significantly different (4.45% vs. 2.59%, p < 0.01) after 10 days of storage. There were no significant differences between the two types of refrigerator in terms of the other measurements. Additionally, the overall acceptability of the pork loin did not vary significantly between the control and the SC when the sensory evaluation was performed. Therefore, a commercial SC could prove beneficial in terms of water holding capacity during the short-term storage of meat. Further research should be performed to evaluate quality changes that occur during long-term storage of meat in SC s and evaluate a wide range of meat, such as beef and chicken.

Determination of Optimal Storage Condition for Pre-packed Hanwoo Loin

  • Seol, Kuk-Hwan;Park, Tu San;Oh, Mi-Hwa;Park, Beom-Young;Cho, Seong In;Lee, Mooha
    • 한국축산식품학회지
    • /
    • 제33권3호
    • /
    • pp.390-394
    • /
    • 2013
  • The aim of this study was to determine the optimal storage condition of pre-packed Hanwoo beef without freezing. Hanwoo loin was purchased from a local distributor at 48 h after slaughter, then sliced in $1.5{\pm}0.5$ cm thickness, and packed in a polyethylene (PE) tray covered with linear low-density polyethylene (LLDPE) film. The studied factors to set the optimal storage condition were chamber temperature (5, 2.5 and $-1^{\circ}C$ for 14 d), cooling method (direct and indirect cooling system), and ultraviolet (UV) light irradiation for beef surface sterilization (0, 30, 60, and 120 min). The changes of pH, thiobarbituric acid reactive substances (TBARS) and number of aerobic bacteria were measured during storage. Beef samples stored in $-1^{\circ}C$ showed the minimal increasing rate in TBARS and microbial growth. After 15 d of storage, there was no significant difference in pH and TBARS values. However, the microbial population of beef stored in direct type cooling chamber ($4.25{\pm}0.66$ Log CFU/g) was significantly lower than that of beef stored in indirect type chamber ($6.47{\pm}0.08$ Log CFU/g) (p<0.05). After 4 d of storage, 60 or 120 min UV light irradiated beef samples showed significantly lower microbial population, and at 14 d of storage, 60 min UV irradiated beef sample showed significantly lower microbial population ($3.14{\pm}0.43$ Log CFU/g) than control ($4.46{\pm}0.13$ Log CFU/g) (p<0.05). However, TBARS values of 60 or 120 min UV light irradiated beef samples were significantly higher than non-irradiated beef sample after 4 d of storage (p<0.05).

동결된 화강풍화토와 알루미늄판 접촉면에서 발현되는 동착강도 측정 연구 (A Study for Adfreeze Bond Strength Developed between Weathered Granite Soils and Aluminum Plate)

  • 이준용;김영석;최창호
    • 한국지반환경공학회 논문집
    • /
    • 제14권12호
    • /
    • pp.23-30
    • /
    • 2013
  • 비동결된 지반에서의 말뚝기초 지지력은 주면마찰력과 선단지지력에 의해 지배되는 것과 달리 동토지역에서의 말뚝기초지지력은 일반적으로 주면마찰력에 의해 지배된다. 동토지역에서 말뚝기초와 동결토 사이 접촉면에서 발현하는 주면마찰력은 동착강도로 정의하며, 동착강도는 동토지역 말뚝기초의 설계 지배정수로 알려져 있다. 동토지역에서 말뚝기초의 지지력을 지배하는 설계정수인 동착강도 특성을 분석하기 위하여 지난 50여 년 동안 많은 연구가 수행되었으며, 현재에도 활발히 연구가 수행 중에 있다. 하지만 동착강도의 경우 토사의 물성특성, 말뚝표면의 거칠기 및 외부적인 시험조건에 의하여 민감하게 반응하는 것으로 알려져 있어 현재까지 진행된 많은 연구들은 제한된 영향인자를 고려하여 수행되었다. 본 연구에서는 동결온도 및 수직응력 조건에 따른 동착강도 특성을 분석하기 위하여 대형 냉동챔버 내에서 직접전단시험을 수행하였으며, 시험결과를 바탕으로 기존에 동일한 조건으로 측정된 동결토 전단강도와 상관관계를 분석하였다. 또한, 향후 동결토 전단강도를 활용하여 동착강도를 추정할 수 있는 동착강도 비례계수를 산정하였으며, 기존 연구와의 비교분석을 통하여 기존 계수에 대한 문제점을 고찰하였다.

낮은 구속응력에서 모래-실트 혼합토의 동결강도 평가를 위한 동적 콘 저항력 및 전단강도 상관성 연구 (Study on Correlation between Dynamic Cone Resistance and Shear Strength for Frozen Sand-Silt Mixtures under Low Confining Stress)

  • 김상엽;이종섭;홍승서;변용훈
    • 한국지반환경공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.5-12
    • /
    • 2016
  • 극한지에서는 환경적 요인과 접근성의 한계에 따라, 동결토의 강도를 현장 상태에서 파악하기 어렵다. 본 연구에서는 극한지 현장의 동결강도를 평가하기 위하여 계장화된 동적 콘 관입기로부터 산정된 동적 콘 저항력과 직접전단실험으로부터 획득된 전단강도 간의 상관성을 조사하였다. 실트가 혼합된 주문진사를 함수비 2.3%로 동일하게 조성하였으며, 시료를 냉동 챔버 내에서 동결시킨 후 직접전단실험과 동적 콘 관입실험을 진행하였다. 실험은 동결과정 및 전단과정, 그리고 동적 콘 관입과정에서 수직응력을 5kPa 및 10kPa로 조합한 4가지 경우로 구성하였으며 이에 따른 동적 콘 관입지수와 전단강도를 산정하였다. 또한 해머타격으로부터 전달되는 에너지의 손실에 대한 영향을 최소화하기 위하여 선단에서 산정된 에너지 및 변위를 이용함으로써 동적 콘 저항력을 산출하였다. 직접전단실험 및 동적 콘 관입실험을 수행한 결과 구속조건에 의한 전단강도의 증가에 따라 동적 콘 관입지수는 비선형적으로 감소하였으며, 동적 콘 저항력은 전단강도와 선형적으로 비례하는 관계로 나타났다. 본 연구는 동결토에 대한 동적 콘 관입실험과 직접전단실험을 통한 강도정수를 비교 및 평가한 연구이며 본 연구에서 도입된 동적 콘 저항력은 극한지 현장에서 동결토의 강도를 추정하기 위한 유용한 지표가 될 수 있을 것으로 기대된다.

동결온도조건 및 수직구속응력에 따른 동결토의 전단강도 변화에 관한 연구 (A study for Shear Strength Characteristics of Frozen Soils under Various Temperature Conditions and Vertical Confining Pressures)

  • 이준용;최창호
    • 한국지반환경공학회 논문집
    • /
    • 제13권11호
    • /
    • pp.51-60
    • /
    • 2012
  • 동토지반의 기초구조물을 설계하는데 있어 기초의 안정성을 지배하는 설계정수인 동결토의 전단강도 및 동착강도를 측정하기 위하여 지난 50여 년 동안 많은 연구가 수행되어 오고 있다. 하지만, 아직까지 동결토의 전단강도 특성에 관한 많은 연구들은 토사 종류, 수직구속응력, 동결온도조건 등 여러 가지 영향인자 중 제한된 영향인자의 변화를 통해 수행되어 왔다. 동결토는 일반 토질과는 달리 토립자, 물, 공기뿐만 아니라 얼음을 포함한 4상으로 구성되어 있으며, 동토의 역학적인 성질의 변화는 일반적으로 온도, 수직구속응력, 동토의 구성물질에 따라 영향을 받는다. 이와 같은 동결토의 전단강도 특성을 측정하기 위하여 영하 30도의 저온환경에서도 동작이 가능하도록 설계된 동결토 직접전단시험기를 활용하였으며, 동토지역의 저온환경을 모사하기 위하여 대형 냉동챔버 내에 직접전단시험기를 설치하였다. 동결토의 전단강도 특성을 측정하기 위하여 비교적 균질한 입경분포를 지닌 주문진표준사 및 실리카모래와 입도분포가 좋은 화강풍화토를 활용하였다. 각각 세가지 시료에 대하여 전단시험은 세가지 동결온도 조건 및 수직구속응력 조건에서 수행되었으며, 그 결과를 바탕으로 동결온도조건 및 수직구속응력이 동결토의 전단강도에 미치는 영향을 분석하였다. 전반적으로 동결토의 전단강도는 동결온도가 낮아질수록 증가하는 경향을 보였으나, 수직구속응력에 의한 영향은 미미한 것으로 나타났다.