• Title/Summary/Keyword: Free gait

Search Result 47, Processing Time 0.02 seconds

Characteristics of the Compensation for Gait of the Induced Knee Stiffness in Normal Subjects (정상인 보행에서 무릎관절의 유도된 강직에 따른 신체 보상 특성)

  • Woo, Byung-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.357-367
    • /
    • 2013
  • The purposes of this study were investigated physical compensation for gait on induced knee stiffness in normal subjects. Ten subjects were participated in the experiment(age: $26.0{\pm}6.3$ yrs, height: $175.5{\pm}5.3$ cm, weight: $69.1{\pm}6.1$ kg). The study method adopted 3D analysis with five cameras and ground reaction force with two force-plate. Induced knee stiffness level were classified as gait pattern on ROM of knee(free level, $30^{\circ}$ restriction level, fix level). The results were as follows; In angular displacement of hip joint, left hip joint was the more extended in mid-stance on induced right knee stiffness. In angular displacement of knee joint, there was no physical compensation on induced right knee stiffness, but free knee level gait was more flexed in swing phase of right knee joint. In angular displacement of ankle joint, right ankle joint was the more dorsiflexed on induced right knee stiffness, and $30^{\circ}$ restriction level and fix level gait were less plantarflexed in TO2. In trunk tilt, free and $30^{\circ}$ restriction level gait was more backward tilt on induced right knee stiffness. In ROM of each joint, right knee joint was more larger and trunk tilt was more lower on induced right knee stiffness. In GRF, Fx was more bigger lateral force in free and $30^{\circ}$ restriction level gait, and was more bigger medial force in fix level gait. Fy was more bigger propulsion force in free level gait, and was was more bigger braking force in $30^{\circ}$ restriction level gait. Left braking force in $30^{\circ}$ restriction level gait was more bigger. Fz was no significant.

The Changes of Joint Moments According to Weight Loading Gait on Normal Adults (정상 성인의 무게 부하 보행이 관절 모멘트의 변화에 미치는 영향)

  • Chung, Hyung-Kuk
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.53-61
    • /
    • 2003
  • The purposes of this study were to describe and compare pint moments according to 6 types of gait methods during free speed. 15 volunteers(7 male, 8 female: mean age = 23.33 yrs.) participated and performed 6 types of gait methods. From the 3 types of pint moments of lower extremities(hip, knee, ankle and foot), the following results were made: 1. In left hip pint, the flexion-extension moment was not significantly different, but the adduction-abduction moment and rotation moment were showed different curves during stance phase. 2. In left knee pint, the flexion-extension moment was not significantly different, but the varus-valgus moment and rotation moment were showed different curves during stance phase. 3. In left ankle and foot the dorsiflexion-plantarflexion moment was not significantly different but the varus-valgus moment and rotation moment were showed different curves during stance phase. In conclusion, because weight loading gait with 10-20% of body weight were normal gait patterns, It was inferred that all weight loading gaits did not indicate noxious reactions of human body.

  • PDF

The effect of training using rhythmic auditory stimulation on gait of stroke patients (청각자극(Rhythmic Auditory Stimulation)을 이용한 훈련이 뇌졸중 환자의 보행에 미치는 효과)

  • Park, Kee-eon;Lee, Insung;Oh, Jaegun;Lee, Ilsuk;Choi, Sanho;Lee, Sangkwan;Sung, Kang-keyng
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • ■ Objectives The goal of this pilot study is to observe the change of stroke gait by auditory cue training. ■ Methods An intracranial hemorrhage patient was trained for 4 weeks. For the 1st consecutive 6days(the 1st week), the patient was trained to walk with auditory cue, what was called auditory cue gait training condition. For the 2nd consecutive 6days(the 2nd week), the patient was trained to walk naturally without auditory cue, what was called free gait training condition. For the 3rd consecutive 6days(the 3rd week), the patient was trained to walk under auditory cue gait training condition. For the 4th consecutive 6days(the 4th week), the patient was trained to walk under free gait training condition. We analyzed the gait using a treadmill gait analysis system 3 hours after the 6th gait training. ■ Results Auditory cue gait training showed effects on gait parameters, which were increasing walking velocity, step length, stride length, decreasing cadence, step time and stride time. ■ Conclusion Auditory cue gait training improved gait parameters of a stroke patient.

  • PDF

Development of the Automatic Knee Joint Control System for a Knee-Ankle-Foot Orthosis Using an Electromechanical Clutch (전자-기계식 클러치를 이용한 장하지 보조기용 무릎관절 자동 제어 장치의 개발)

  • 이기원;강성재;김영호;조강희
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.359-368
    • /
    • 2001
  • A new knee-ankle-foot-orthosis(KAFO) which uses an automatically-controlled electromechanical wrap spring clutch for the knee joint was developed in the present study. It was found that the output voltage from the foot switches of the developed KAFO was proportionally increased with respect to the applied load. The output voltage from the infrared sensor also decreased as the knee flexion angle increased. The knee joint system for the new KAFO weighs only 780g lighter than any other commercially available developed system. In addition, the solenoid reduces the reaction time for the automatic control of the knee joint. The static torque of the clutch was measured for three persons, and it satisfied the normal knee extension moment during the pre-swing. Three-dimensional gait analyses for three different gait patterns (normal gait, locked-knee gait, controlled-knee gait) from five normal subjects were conducted. Controlled-knee gait showed the maximum knee flexion angle of 40.56$\pm9.55^{\circ}$ and the maximum knee flexion moment of 0.20$\pm$0.07Nm/kg at similar periods in the normal gait. Our KAFO system satisfies both stability during stance phase and free knee flexion during the swing phase at the proper period during the gait cycle. Therefore, our KAFO system would be very useful in various low extremity orthotic applications.

  • PDF

Fault-Tolerant Tripod Gaits Considering Deadlock Avoidance (교착 회피를 고려한 내고장성 세다리 걸음새)

  • 노지명;양정민
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.8
    • /
    • pp.585-593
    • /
    • 2004
  • Fault-tolerant gait planning in legged locomotion is to design gaits with which legged robots can maintain static stability and motion continuity against a failure in a leg. For planning a robust and deadlock-free fault-tolerant gait, kinematic constraints caused by a failed leg should be closely examined with respect to remaining mobility of the leg. In this paper, based on the authors's previous results, deadlock avoidance scheme for fault-tolerant gait planning is proposed for a hexapod robot walking over even terrain. The considered fault is a locked joint failure, which prevents a joint of a leg from moving and makes it locked in a known position. It is shown that for guaranteeing the existence of the previously proposed fault-tolerant tripod gait of a hexapod robot, the configuration of the failed leg must be within a range of kinematic constraints. Then, for coping with failure situations where the existence condition is not satisfied, the previous fault-tolerant tripod gait is improved by including the adjustment of the foot trajectory. The foot trajectory adjustment procedure is analytically derived to show that it can help the fault-tolerant gait avoid deadlock resulting from the kinematic constraint and does not make any harmful effect on gait mobility. The post-failure walking problem of a hexapod robot with the normal tripod gait is addressed as a case study to show the effectiveness of the proposed scheme.

The Kinematic Patterns of Walking according to Obstacle's Height (장애물 높이에 따른 보행의 운동형상학적 변화에 대한 연구)

  • Chung, Hyung-Kuk
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.3
    • /
    • pp.55-63
    • /
    • 2008
  • Background : The Purposes of this study were to understand difference between free walking and obstacle over walking through the naked eye and motion analysis device, and to review merits of obstacle walking training as item of functional assessment in clinical situations. Methods : All participants were male and performed 3 types of walking methods: free walking, obstacle over walking with low block(height=10cm, width=8cm), and obstacle over walking with high block(height=20cm, width=8cm). All walking were performed 3 trials respectively. Results : In the naked eye, initial contact with toes occurred more than heel strike in obstacle over walking, and the flexion angle of hip and knee were increased in obstacle over walking. On interpretations though motion analysis device, cadence, gait speed and weight accept were significant statistically(p<.05). Cadence and gait speed were decreased, and weight accept duration was increased in obstacle over walking. Rotation among three pelvic motions was significant statistically(p<.05), flexion among three hip motions was significant statistically(p<.05) and flexion among three ankle motions was significant statistically(p<.05). Rotation and flexion among three ankle motions was significant statistically(p<.05). Conclusion : Both the naked eye and interpretations of the device presented many difference between free walking and obstacle over walking. In overcrossing obstacles, many participants appeared walking strategy by perform initial contact with toes. Knee flexion was most significant statistically(p<.05) in obstacle over walking with 20cm block.

  • PDF

Seafarers Walking on an Unstable Platform: Comparisons of Time and Frequency Domain Analyses for Gait Event Detection

  • Youn, Ik-Hyun;Choi, Jungyeon;Youn, Jong-Hoon
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.244-249
    • /
    • 2017
  • Wearable sensor-based gait analysis has been widely conducted to analyze various aspects of human ambulation abilities under the free-living condition. However, there have been few research efforts on using wearable sensors to analyze human walking on an unstable surface such as on a ship during a sea voyage. Since the motion of a ship on the unstable sea surface imposes significant differences in walking strategies, investigation is suggested to find better performing wearable sensor-based gait analysis algorithms on this unstable environment. This study aimed to compare two representative gait event algorithms including time domain and frequency domain analyses for detecting heel strike on an unstable platform. As results, although two methods did not miss any heel strike, the frequency domain analysis method perform better when comparing heel strike timing. The finding suggests that the frequency analysis is recommended to efficiently detect gait event in the unstable walking environment.

Walkability on Ramps by Gait Analysis (보행자세해석에 의한 경사로의 보행성)

  • 유남형
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.2
    • /
    • pp.157-166
    • /
    • 1995
  • To investigate walkability of ramps, walking patterns of 18 healthy adults,12 aged 20 to 26 and 6 aged 68 to 76,were studied at free,rhythm constrained walking up or down ramp using goniometer and footswitch Ramp inclinations were set 4,8,12,16,20 degrees. The results were as follows. 1)The step length of subjects were decreased significantly in12$^{\circ}C$′or 16′free downramp walking. With regard to step length, some subject groups walked abnormally in 16" or 20" ramp walking 2) The step width of subjects were increased significantly in 12" or 16" ramp walking. 3) The cadence duration of some subject groups were increased in 12" upramp walking. 4) The double stance duration and double stance ratio of some subject groups were increased significantly in 8",12", or 16"upramp walking. 5) The maximum knee flexion angle of stance phase were increased in 12" ramp walking. 6)Most temporal parameters and spatial parameters of gait were increased or decreassd greatly between 4" ramp and 8" ramp or between 8′ramp and 12′ramp. But statistics significancy were not recognized 7) The results suggest that ramp inclination less than 8′(14%) -12′(21%) is desirable for the normal gait the ramp inclination must not exceed 16" -20" in unavoidable circumstances.

  • PDF

Characteristics of Pelvic Ranges According to Artificial Leg Length Discrepancy During Gait: Three-Dimensional Analysis in Healthy Individuals (보행 중 인위적 다리길이 차이에 따른 3차원적 골반 가동범위의 특성)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.59-67
    • /
    • 2019
  • Purpose : The purpose of this study was to analyze the dynamic range of motion (ROM) of pelvic and translation of center of mass (COM) when wearing different shoe insole lifts according to leg length discrepancy (LLD) during free speed gait. Methods : Thirty-five healthy adults were participated in this study. Kinematic data were collected using a Vicon motion capture system. Reflective and cluster 40 markers attached to participants lower extremities and were asked to walk in a 6 m gait way under three different shoe lift conditions (without any insole, 1 cm insole, and 2 cm insole). The pelvic ROM and COM translation in three planes were sorted using a Nexus software, and a Visual3D motion analysis software was used to coordinate all kinematic data. Results : There were significantly increased maximal pelvic elevation and total pelvic range in coronal plane when wearing a standard shoe with 2 cm insole lift during gait (p<.05). When wearing a standard shoe with 2 cm insole lift, the total range of the pelvic segment were significantly different in all three motion planes (p<.05). Conclusion : Although LLD of less than 2 cm develops abnormal movement pattern of the pelvis and may cause of musculoskeletal diseases such as low back pain, hip and knee joint osteoarthritis, therefore intensive various physical therapy interventions for LLD are needed.

A Method of Path Planning for a Quadruped Walking Robot on Irregular Terrain (불규칙 지형에서 사가 보행 로보트의 경로 계획 방법)

  • ;Zeungnam Biem
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.329-338
    • /
    • 1994
  • This paper presents a novel method of path planning for a quadruped walking robot on irregular terrain. In the previous study on the path planning problem of mobile robots, it has been usually focused on the collision-free path planning for wheeled robots. The path planning problem of legged roboth, however, has unique aspects from the point of viw that the legged robot can cross over the obstacles and the gait constraint should be considered in the process of planning a path. To resolve this unique problem systematically, a new concept of the artificial intensity field of light is numerically constructed over the configuration space of the robot including the transformed obstacles and a feasible path is sought in the field. Also, the efficiency of the proposed method is shown by various simulation results.

  • PDF