• Title/Summary/Keyword: Free fluid

Search Result 1,060, Processing Time 0.024 seconds

Acoustic responses of natural fibre reinforced nanocomposite structure using multiphysics approach and experimental validation

  • Satankar, Rajesh Kumar;Sharma, Nitin;Ramteke, Prashik Malhari;Panda, Subtra Kumar;Mahapatra, Siba Shankar
    • Advances in nano research
    • /
    • v.9 no.4
    • /
    • pp.263-276
    • /
    • 2020
  • In this article, the acoustic responses of free vibrated natural fibre-reinforced polymer nanocomposite structure have been investigated first time with the help of commercial package (ANSYS) using the multiphysical modelling approach. The sound relevant data of the polymeric structure is obtained by varying weight fractions of the natural nanofibre within the composite. Firstly, the structural frequencies are obtained through a simulation model prepared in ANSYS and solved through the static structural analysis module. Further, the corresponding sound data within a certain range of frequencies are evaluated by modelling the medium through the boundary element steps with adequate coupling between structure and fluid via LMS Virtual Lab. The simulation model validity has been established by comparing the frequency and sound responses with published results. In addition, sets of experimentation are carried out for the eigenvalue and the sound pressure level for different weight fractions of natural fibre and compared with own simulation data. The experimental frequencies are obtained using own impact type vibration analyzer and recorded through LABVIEW support software. Similarly, the noise data due to the harmonically excited vibrating plate are recorded through the available Array microphone (40 PH and serial no: 190569). The numerical results and subsequent experimental comparison are indicating the comprehensiveness of the presently derived simulation model. Finally, the effects of structural design parameters (thickness ratio, aspect ratio and boundary conditions) on the acoustic behaviour of the natural-fibre reinforced nanocomposite are computed using the present multiphysical model and highlighted the inferences.

Brief review of cancer treatment focused on JIJU(積聚) (적취(積聚)를 위주로 한 종양(腫瘍)의 치법(治法)에 관한 소고(小考))

  • Park, Jae-Hyun;Moon, Goo
    • Journal of Korean Traditional Oncology
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Objectives: To grasp the traditional stream of cancer treatment inherited from the previous doctors. Methods: The author's research has been performed cancer treatment based on JIJU(積聚) taking the original text as a reference. Results & Conclusion: The general three outlines and five detailed rules of cancer treatment have been obtained as follows. The first outline of cancer treatment is that reinforced vital function makes cancer reduce naturally. the second is that Harmless cancer can coexist in human beings and aging with them. and the third is that Elimination and reinforcing therapies should be executed in appropriate era and those therapies should utilize appropriate methods. The first detailed rule of cancer treatment is when using reinforcing therapy, it must applicate mildly and when using elimination therapy, it must applicate calmly. The second detailed rule is that the methods of cancer treatment are different from each cancer stage. The concentration should be made on reinforcing therapy at early stage while reinforcing and elimination therapies must be conducted together at middle stage. At terminal stage reinforcing therapy is the sole method to be taken. The third detailed rule is that the basis property of cancer drug is warm nature and extremely biased property should be avoided and when complication arises (eg. inflamatory disease, cancer fever, etc), cold or cool nature can be applied. The fourth detailed rule is that Cancer drug must have the effect eliminating the blood stasis, phlegm and excessive fluid, all together. The fifth detailed rule is that Physicians have to control patient's stress or stress related symptom and teach patients about right way of taking care of themselves and patients should take hygienic rules with their free will by themselves (eg diet, exercise, stress, etc)

  • PDF

Bioglue-Coated Teflon Sling Technique in Microvascular Decompression for Hemifacial Spasm Involving the Vertebral Artery

  • Lee, Seong Ho;Park, Jae Sung;Ahn, Young Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.505-511
    • /
    • 2016
  • Objective : Microvascular decompression (MVD) for hemifacial spasm (HFS) involving the vertebral artery (VA) can be technically challenging. We investigated the therapeutic effects of a bioglue-coated Teflon sling technique on the VA during MVD in 42 cases. Methods : A bioglue-coated Teflon sling was crafted by the surgeon and applied to patients in whom neurovascular compression was caused by the VA. The radiologic data, intra-operative findings with detailed introduction of the procedure, and the clinical outcomes of each patient were reviewed and analyzed. Results : The 42 patients included in the analysis consisted of 22 females and 20 males, with an average follow-up duration of 76 months (range 24-132 months). Intraoperative investigation revealed that an artery other than the VA was responsible for the neurovascular compression in all cases : posterior inferior cerebellar artery (PICA) in 23 patients (54.7%) and anterior inferior cerebellar artery (AICA) in 11 patients (26.2%). All patients became symptom-free after MVD. Neither recurrence nor postoperative neurological deficit was noted during the 2-year follow-up, except in one patient who developed permanent deafness. Cerebrospinal fluid (CSF) leak occurred in three patients, and one required dural repair. Conclusion : Transposition of the VA using a bioglue-coated Teflon sling is a safe and effective surgical technique for HFS involving the VA. A future prospective study to compare clinical outcomes between groups with and without use of this novel technique is required.

Surgical Outcome of Adult Idiopathic Chiari Malformation Type 1

  • Yuh, Woon Tak;Kim, Chi Heon;Chung, Chun Kee;Kim, Hyun-Jib;Jahng, Tae-Ahn;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.512-517
    • /
    • 2016
  • Objective : The pathophysiology of idiopathic Chiari malformation (CM) type 1 is disturbance of free cerebrospinal fluid (CSF) flow and restoration of normal CSF flow is the mainstay of treatment. Additional migration of the medulla oblongata in pediatric patients is referred to as CM type 1.5, but its significance in adult patients is unknown. This study is to compare surgical outcomes of adult idiopathic CM type 1.5 with that of type 1. Methods : Thirty-eight consecutive adult patients (M : F=11 : 27; median, 33.5; range, 18-63) with syringomyelia due to idiopathic CM type 1 were reviewed. Migration of the medulla oblongata was noted in 13 patients. The modified McCormick scale (MMS) was used to evaluate functional status before and one year after surgery. All patients underwent foramen magnum decompression and duroplasty. Factors related to radiological success (${\geq}50%$ decrease in the diameter of the syrinx) were investigated. The follow-up period was $72.7{\pm}55.6$ months. Results : Preoperative functional status were MMS I in 11 patients and MMS II in 14 of CM type 1 and MMS I in 8 and II in 5 of CM type 1.5. Of patients with MMS II, 5/14 patients in group A and 3/5 patients in group B showed improvement and there was no case of deterioration. Radiological success was achieved in 32 (84%) patients and restoration of the cisterna magna (p=0.01; OR, 46.5) was the only significant factor. Conclusion : Migration of the medulla oblongata did not make a difference in the surgical outcome when the cisterna magna was restored.

Angular-based Measurement for Quantitative assay of Albumin in three-dimensional Paper-based analytical Device (회전각도를 이용한 알부민 농도 측정용 3차원 종이 칩)

  • Kim, Dong-Ho;Jeong, Seong-Geun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.286-292
    • /
    • 2020
  • This study presents an angular-based measurement on three-dimensional paper-based analytical devices (3D-PADs) for quantitative detection of albumin without using an image analyzer. We demonstrate a simple quantitative and straightforward approach based on the angle of the discolored area as detection criteria. 3D-PADs are rapidly fabricated by the wax-printing and laminating process. The 3D-PADs are treated with citrate buffer and tetrabromophenol blue to react with albumin in a sample solution. Dropping sample solution into sample pad in the 3D-PAD, fluid flows toward the assay zone laterally and vertically by capillary action. We find that the change of angle of the discolored area correctly reflects the concentration of albumin and is reliable determinant for the measurement of the albumin concentration. It is the first demonstration of angular-based detection as a simple, inexpensive, and equipment-free approach for point-of-care diagnosis.

Development of 25.8kV class solid insulated switchgear (25.8kV 고체절연스위치기어 개발)

  • Lee, J.H.;Ma, J.H.;Yu, L.;Lee, J.G.;Won, S.Y.;Lee, S.W.;Kim, Y.G.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

Numerical Study on the Side-Wind Aerodynamic Forces of Chambered 3-D Thin-Plate Rigid-Body Model (캠버가 있는 3차원 박판 강체 모형의 측풍 공기력에 대한 수치 연구)

  • Shin, Jong-Hyeon;Chang, Se-Myong;Moon, Byung-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.97-108
    • /
    • 2015
  • In the design of sailing yachts, para-glider, or high-sky wind power, etc., the analysis of side-wind aerodynamic forces exerted on a cambered 3-D model is very important to predict the performance of various machinery systems. To understand the essential flow physics around the three-dimensional shape, simplified rigid-body models are proposed in this study. Four parameters such as free stream velocity, angle of attack, aspect ratio, and camber are considered as the independent variables. Lift and drag coefficients are computed with CFD technique using ANSYS-CFX, and the results with the visualization of post-processed flow fields are analyzed in the viewpoint of fluid dynamics.

Fatal Balamuthia Amebic Encephalitis in a Healthy Child: A Case Report with Review of Survival Cases

  • Krasaelap, A.;Prechawit, S.;Chansaenroj, J.;Punyahotra, P.;Puthanakit, T.;Chomtho, K.;Shuangshoti, S.;Amornfa, J.;Poovorawan, Y.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.3
    • /
    • pp.335-341
    • /
    • 2013
  • Balamuthia mandrillaris is one of the 4 amebas in fresh water and soil that cause diseases in humans. Granulomatous amebic encephalitis (GAE), caused by B. mandrillaris, is a rare but life-threatening condition. A 4-year-old, previously healthy, Thai girl presented with progressive headache and ataxia for over a month. Neuroimaging studies showed an infiltrative mass at the right cerebellar hemisphere mimicking a malignant cerebellar tumor. The pathological finding after total mass removal revealed severe necrotizing inflammation, with presence of scattered amebic trophozoites. Cerebrospinal fluid (CSF) obtained from lumbar puncture showed evidence of non-specific inflammation without identifiable organisms. A combination of pentamidine, sulfasalazine, fluconazole, and clarithromycin had been initiated promptly before PCR confirmed the diagnosis of Balamuthia amebic encephalitis (BAE). The patient showed initial improvement after the surgery and combined medical treatment, but gradually deteriorated and died of multiple organ failure within 46 days upon admission despite early diagnosis and treatment. In addition to the case, 10 survivors of BAE reported in the PubMed database were briefly reviewed in an attempt to identify the possible factors leading to survival of the patients diagnosed with this rare disease.

Antiallergic Effect of Two Variants of Artemisia princeps Pampanini

  • Shin, Yong-Wook;Bae, Eun-Ah;Lee, Bo-Mi;Min, Sung-Won;Lee, Jin-Hee;Baek, Nam-In;Ryu, Su-No;Chung, Hae-Gon;Kim, Nam-Jae;Kim, Dong-Hyun
    • Natural Product Sciences
    • /
    • v.12 no.2
    • /
    • pp.67-73
    • /
    • 2006
  • Antiallergic activities of two variants of Artemisia princeps Pampanini SJ-1 (named as Sajabalssuk) and SS-1 (named as Sajuarissuk) cultivated in Ganghwado, which contain high content of eupatilin compared to those cultured by other places, were investigated to evaluate the possibility as inhibitors against allergic diseases. Ethanol and supercritical fluid extracts of SJ-1 and SS-1 inhibited the release of ${\beta}-hexosaminidase$ from RBL-2H3 cells, although their water extracts were inactive. These extracts potently inhibited lipopolysaccharide-induced NO production of RAW264.7. However, these extracts almost did not scavenge free radicals. Oral administration of these extracts to mice inhibited passive cutaneous anaphylaxis reaction induced by IgE, and acute dermatitis induced by 12-O-tetradecanoylphorbol-13-acetate. However, these extracts did not inhibit chronic dermatitis. Scratching behaviors, vascular permeability, and writhing syndromes were weakly inhibited by these extract at a dose of 50 mg/kg. Based on these findings, we believe that SJ-1 and SS-1 can improve IgE-induced allergic diseases such as rhinitis and asthma.

A Study on Dynamic Characteristics of Hydraulic Motor Brake System with Counter Balance Valve (카운터 밸런스 밸브를 내장한 유압 모터 브레이크 시스템의 동특성)

  • Yun, So-Nam;Lee, Ill-Yeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.3
    • /
    • pp.214-219
    • /
    • 1993
  • Counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. These problems may hurt system safety and driver's conformability. Nevertheless, studies on dynamic characteristics of hydraulic system including counter balance valve are very rare, so further accumulation of research results are required. In this study, for the purpose of easy estimation about dynamic characteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. The equations obtained in the preceding process include some parameters that must be got experimentally. Flow coefficients of valve and choke are the most significant ones among the parameters. So these parameters are obtained experimentally in this study, and experimental equations obtained from the experimental data were used for numerical calculation. The equations were analysed by numerical integration using Runge-Kutta method, because the equations contain various nonlinear terms. From the numerical analysis, it was verified that the dynamic response of counter balance valve and pressure variation at each elements can be estimated very easily. So the analysing method developed in this study enabled very easy estimating the relation between the performances of counter balance valve and various physical parameters related to the valve. Conclusively, it is said that the results obtained in this study can be used very usefully to develop a new type counter balance valve or to apply the valve to actual hydraulic system for various industrial equipments.

  • PDF