• 제목/요약/키워드: Free electron laser

검색결과 72건 처리시간 0.031초

Pulsed Nd : YAG 레이저 조사와 불소 화합물 도포가 초기 우식 법랑질의 표면 경도에 미치는 영향 (Effects of Pulsed Nd:YAG Laser Irradiation and Fluoride Compound Application on Surface Hardness of Incipient Carious Lesion in Enamel of Bovine Teeth)

  • Jun-Bong Kwag;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.207-224
    • /
    • 1996
  • This study was designed to determine the most effective concentration of fluoride and energy density of laser irradiation for the anticarious effect. For this study surface hardness in enamel was measured before and after irradiation with pulsed Nd;YAG laser and the topical application of fluoride. Of the permanent mandibular anterior hovine teeth, healthy, carious free ones were used. Three hundred specimens were made. Specimens within 25~45 Vickers hardness numbers were assigned to 20 control and experimental stoops ; each containing 15 specimens. After forming artificial carious lesions, 10 J/$\textrm{cm}^2$, 20 J/$\textrm{cm}^2$, and 30 J/$\textrm{cm}^2$ energies were irradiated on the enamel surface of each experimental group. Also NaF, NH4F, Elmex gel(amine fluoride) and APF gel fluoride compounds were applied topically. Next, all the specimens were placed into the pH circulatory procedures for eight days. Vickers hardness numbers were measured using a microhardness tester. Surface changes of the enamel were observed using an scanning electron microscope. The comparative ana1ysis yielded the following results : 1. The reduction of surface hardness of the enamel surface was less in all groups with fluoride application than in the group without fluoride application. 2. The APF gel croup with 10 J/$\textrm{cm}^2$ irradiation showed the lowest reduction of surface hardness. 3. The reduction of surface hardness of the enamel surface in the group of laser irradiation without fluoride application not showed any significant difference according to the energy density of the laser. 4. Under the scanning electron microscope, in enamel irradiated with 10J/$\textrm{cm}^2$ showed appearance similar to acid etching surface. In enamel irradiated with 20 J/$\textrm{cm}^2$, line enamel crack was detected. In enamel irradiated with 30j/$\textrm{cm}^2$, severe enamel crack and fusion of enamel were detected. These results suggest that one could obtain the best anticariogenic effects without damage to teeth in the group of application of APF gel after laser irradiation with 10 J/$\textrm{cm}^2$.

  • PDF

Coherent Diffraction Imaging at PAL-XFEL

  • Kim, Sangsoo;Nam, Kihyun;Park, Jaehyun;Kim, Kwangoo;Kim, Bongsoo;Ko, Insoo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.85.2-85.2
    • /
    • 2016
  • With the advent of ultra-short high-intense XFEL (X-ray Free Electron Laser), time-resolved dynamics has become of great importance in exploring femtosecond real-world phenomena of nanoscience and biology. These include studying the response of materials to femtosecond laser excitation and investigating the interaction of XFEL itself with condensed matter. A variety of dynamic phenomena have been investigated such as radiation damage, ultrafast melting process, non-equilibrium phase transitions caused by orbital-lattice-spin couplings. As far as bulk materials are concerned, the sample size has no effect on the following dynamic process. As a result, imaging information is not required by and large. If the sample size is of tens of nanometers, however, sample starts to experience quantum confinement effect which, in turn, affects the following dynamic process. Therefore, to understand the fundamental dynamic phenomena in nano-science, time-resolved imaging information is essential. In this talk, we will briefly introduce scientific highlights achieved in XFEL-based dynamics. In case of bio-imaging, recent scientific topics will be mentioned as well. Finally, we will aim to present feasible topics in ultrafast time-resolved imaging and to discuss the future plan of CXI beamline at PAL-XFEL.

  • PDF

줄 가열 변화에 따른 박막 트랜지스터 내 포논 열 흐름에 대한 수치적 연구 (Effect of Joule Heating Variation on Phonon Heat Flow in Thin Film Transistor)

  • 진재식;이준식
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.820-826
    • /
    • 2009
  • The anisotropic phonon conductions with varying Joule heating rate of the silicon film in Silicon-on-Insulator devices are examined using the electron-phonon interaction model. It is found that the phonon heat transfer rate at each boundary of Si-layer has a strong dependence on the heating power rate. And the phonon flow decreases when the temperature gradient has a sharp change within extremely short length scales such as phonon mean free path. Thus the heat generated in the hot spot region is removed primarily by heat conduction through Si-layer at the higher Joule heating level and the phonon nonlocality is mainly attributed to lower group velocity phonons as remarkably dissimilar to the case of electrons in laser heated plasmas. To validate these observations the modified phonon nonlocal model considering complete phonon dispersion relations is introduced as a correct form of the conventional theory. We also reveal that the relation between the phonon heat deposition time from the hot spot region and the relaxation time in Si-layer can be used to estimate the intrinsic thermal resistance in the parallel heat flow direction as Joule heating level varies.

자동 정렬 펀칭 시스템의 개발과 디버링 (Development of auto-alignment punching system and de-burring)

  • 홍남표;신홍규;김병희;김헌영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.434-438
    • /
    • 2003
  • The shearing process for the sheet metal is normally used in the precision elements such as semi-conductor components. In these precision elements, the burr formation brings a bad effect on the system assembly and demands the additional de-burring process. In this paper, we have developed the desktop-type precision punching system to investigate the burr formation mechanism and present kinematically Punch-die auto aligning methodology, for the purpose of burr unifomizing and minimizing, between the rectangular shaped punch and die. By using the scanning electron microscope, the aligned punching results are compared with the miss-aligned ones. Also, we measured the relative burr heights using the self-designed laser measuring device for insitu self aligning. Since it is hard to get the perfect, so called, burr-free edges during the shearing process, we introduced the ultrasonic do-burring machine. The de-burring operation was carried out by a novel do-burring method, the reversal flow resistance method, under different machining loads and abrasive types. The final do-burring results show the validity of our punching do-burring system pursuing the burr-free punched elements.

  • PDF

Antibacterial and Antibiofilm Effect of Cell-Free Supernatant of Lactobacillus brevis KCCM 202399 Isolated from Korean Fermented Food against Streptococcus mutans KCTC 5458

  • Kim, Jong Ha;Jang, Hye Ji;Lee, Na-Kyoung;Paik, Hyun-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권1호
    • /
    • pp.56-63
    • /
    • 2022
  • This study aims to determine the antibiofilm effect of cell-free supernatant (CFS) of Lactobacillus brevis strains against Streptococcus mutans strains. To study the antibiofilm mechanism against S. mutans strains, antibacterial effects, cell surface properties (auto-aggregation and cell surface hydrophobicity), exopolysaccharide (EPS) production, and morphological changes were examined. The antibiofilm effect of L. brevis KCCM 202399 CFS as morphological changes were evaluated by scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM), compared with the control treatment. Among the L. brevis strains, L. brevis KCCM 202399 showed the highest antibiofilm effect on S. mutans KCTC 5458. The antibacterial effect of L. brevis KCCM 202399 against S. mutans KCTC 5458 was investigated using the deferred method (16.00 mm). The minimum inhibitory concentration of L. brevis KCCM 202399 against S. mutans KCTC 5458 was 25.00%. Compared with the control treatment, L. brevis KCCM 202399 CFS inhibited the bacterial adhesion of S. mutans KCTC 5458 by decreasing auto-aggregation, cell surface hydrophobicity, and EPS production (45.91%, 40.51%, and 67.44%, respectively). L. brevis KCCM 202399 CFS inhibited and eradicated the S. mutans KCTC 5458 biofilm. Therefore, these results suggest that L. brevis KCCM 202399 CFS may be used to develop oral health in the probiotic industry.

Ultrafast probes of coherent oscillations in Fe-based superconductors

  • Kim, K.W.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.1-4
    • /
    • 2017
  • Forefront ultrafast experimental techniques have recently proven their potential as new approaches to understand materials based on non-equilibrium dynamics in the time domain. The time domain approach is useful especially in disentangling complicated coupling among charge, spin and lattice degrees of freedom. Various ultrafast experiments on Fe-based superconductors have observed strong coherent oscillations of an $A_{1g}$ phonon mode of arsenic ions, which shows strong coupling to the electronic and magnetic states. This paper reviews the recent reports of ultrafast studies on Fe-based superconductor with a focus on the coherent oscillations. Experimental results with ultrashort light sources from the terahertz-infrared pulses to the hard X-rays from a free electron laser will be presented.

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • 세라미스트
    • /
    • 제10권3호
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF

정밀장비의 진동허용규제치에 미치는 인자에 관한 연구 (A Study on the Effected Factor for Vibration Criteria of Sensitive Equipment)

  • 이홍기;장강석;김두훈;김사수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.302-307
    • /
    • 1998
  • In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a sub-micrometer. This equipment requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga and tera class semiconductor wafers. This high technology equipments require very strict environmental vibration standard, vibration criteria, in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria of high sensitive equipment should be represented in the form of exactness and accuracy, because this is used as basic data for the design of building structure and structural dynamics of equipment. The study on the evaluation of the factors affecting the permissible vibration criteria is required to design the efficient isolation system of the semiconductor manufacturing of equipment. This paper deals with the properties of the effected factor for vibration criteria of high sensitive equipment.

  • PDF

마이크로트론을 이용한 소형 원적외선 자유전자레이저에서의 발진 특성 (Output Characteristics of Compact Far Infrared Free Electron Laser driven by a Conventional Microtron)

  • 정영욱;이병철;김선국;조성오;차병헌;이종민
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.48-49
    • /
    • 2000
  • 한국원자력연구소에서는 가속기의 직경이 70 cm이고, 마그네트론 고주파 발생장치를 사용하는 소형 마이크로트론을 이용한 원적외선 자유전자레이저를 개발하였다$^{(1)}$ . 발진 파장은 100 - 200 $mu extrm{m}$ 영역이며, 첨두 출력은 약 1 - 10 kW이다. 본 연구에서는 개발된 원적외선 자유전자레이저의 시스템 개요와 출력 특성에 관하여 살펴보았다. 최근, 반도체와 물성의 분광학연구, 생명공학연구, 광화학 반응연구, 환경감시 기술개발, 인체영상, 군사용 감시기술 개발 등의 분야에서 새로운 연구와 첨단기술개발에 필요한 원적외선 광원의 요구가 점차 높아지고 있다. 이러한 요구에 부응하기 위하여 원적외선 영역의 다양한 광원 개발이 이루어지고 있으며, 특히, 테라헤르쯔 반도체 소자를 개발하기 위한 노력이 국내외에서 활발히 이루어지고 있다. 그러나, 아직까지는 이러한 광원의 출력이 mW 이하이고, 분광특성이 나빠서 실제응용에 많은 제한이 있다. (중략)

  • PDF

준 경험기법을 이용한 고집적 반도체공장의 미진동 제어를 위한 구조물의 동적설계에 관한 연구 (A Study on the Structural Dynamic Design for Sub-micro Vibration Control in High Class Semiconductor Factor by Semi-Empirical Method)

  • 이홍기;백재호;원영재;박해동;김두훈
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1227-1233
    • /
    • 1999
  • Modern technology depends on the reliability of extremely high technology equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a nanometer. This equipment requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga and tera class semiconductor wafers. This high technology equipments require very strict environmental vibration standard, vibration criteria, in proportion to the accuracy of the manufacturing, inspecting devices. This paper deals with the structural dynamic design in high class semiconductor factory in order to be satisfied more strict vibration criteria for high sensitive equipment.

  • PDF