• Title/Summary/Keyword: Free cooling

Search Result 264, Processing Time 0.032 seconds

Effects of C, Mo and Cr on Hardenability and Mechanical Properties of Boron-Bearing Steels (보론강의 경화능과 인장 특성에 미치는C, Mo, Cr의 영향)

  • Yim, H.S.;Jung, W.Y.;Hwang, B.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.26 no.5
    • /
    • pp.241-247
    • /
    • 2013
  • Hardenability and mechanical properties of boron-bearing steels containing C, Mo and Cr were investigated in this study. Using quench dilatometer, the steel specimens were cooled down to room temperature at different cooling rates to construct continuous cooling transformation diagrams and then the transformation products from austenite were examined. A critical cooling rate was introduced as an index to quantitatively evaluate the hardenability. The C addition to boron-bearing steels did not significantly affect hardenability compared to boron-free steels although it increases the hardenability. With the same content, the Mo addition largely increased the hardenability of boron-bearing steels than the Cr addition because it decreased both the transformation start and finish temperatures at low cooling rates. In particular, the Mo addition completely suppressed the formation of eutectoid ferrite even at the slow cooling rate of $0.2^{\circ}C/s$, whereas the Cr addition nearly suppressed it at the cooling rates above $3^{\circ}C/s$.

Cooling Performance of LED Head Lamp with Heat Sink and Cooling Fan (팬과 히트 싱크를 이용한 LED 전조등의 냉각성능 해석)

  • Ko, Man-Seok;Lee, Ju-Han;Oh, Sang-June;Cho, Hyen-Seok;Seo, Tea-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.12
    • /
    • pp.947-951
    • /
    • 2009
  • LED has the merits of high reliability, semi-permanent life, rapid-response and its small size for use as light source of head lamp. But the dependence of its performance and life on temperature affect on its practical use. Which dependence makes problem when the LED is heated up to a higher temperature level by self-generation of heat, due to "highly integration" to get enough quantity of light. To solve this problem, effective cooling system is needed that consider conduction, convection and radiation. This study points out the limits of natural convection cooling system and propose of forced convection with heat sink. Also, it describes a correlation between heat sink area and fluid velocity using numerical analysis to optimize the cooling system.

Heat Dissipation of Sealed LED Light Fixtures Using Pulsating Heat Pipe Technology

  • Kim, Hyung-Tak;Park, Hae-Kyun;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.64-71
    • /
    • 2012
  • An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.

Effects of Agitation and Temperature Activation on Lipolysis in Goat Milk (산양유의 지방분해에 미치는 온도활성화 및 교반의 영향)

  • 김거유;이승범
    • Food Science of Animal Resources
    • /
    • v.20 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • This study was carried out to investigate the effects of temperature activation and agitation on lipolysis of goat milk. When goat milk was temperature activated twice at intervals of 12hours, free fatty acids were significantly increased after the first activation, but increased slightly during the re-cooling period and after the second activation. Lipolysis of the goat milk warmed at $30^{\circ}C$ was significantly facilitated during the re-cooling period. Lipolysis of the goat milk warmed at $30^{\circ}C$ was much higher than those warmed at $10^{\circ}C$ and $40^{\circ}C$ respectively. The highest lipolysis was occurred when the goat milk was warmed at $30^{\circ}C$ for 5 minutes after pre-cooling for 24 hours at $40^{\circ}C$. However, any significant difference was not found in the milk warmed at $40^{\circ}C$, regardless of the pre-cooling period. Lipolysis of the goat milk warmed and agitated at $30^{\circ}C$ was significantly facilitated during the re-cooling period. The lipolysis of that at $30^{\circ}C$ was significantly facilitated during the re-cooling period. The lipolysis of that at $30^{\circ}C$ was much enhanced with agitation. The lipolysis was much higher when agitated at $30^{\circ}C$ than when agitated at $10^{\circ}C$. The length of agitation time at $30^{\circ}C$ didn't give any effect on lipolysis.

  • PDF

Transient cooling operation of multistage thermoelectric cooler (TEC)

  • Park, Jiho;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.55-59
    • /
    • 2021
  • A thermoelectric cooler (TEC) is promising as an alternative refrigeration technology for the sake of its inherent advantages; no-moving parts and refrigerant-free in its operation. Due to the compactness, reliability and excellence in temperature stability, TECs have been widely used for small cooling devices. In recent years, thermoelectric devices have been attractive technologies that not only serve the needs of cooling and heating applications but also meet the demand for energy by recycling waste heat. In this research paper, multistage TEC is proposed as a concept of demonstrating the idea of transient cooling technology. The key idea of transient cooling is to harnesses the thermal mass installed at the interfacial level of the stages. By storing heat temporally at the thermal mass, the multistage TEC can readily reach lower temperatures than that by a steady-state operation. The multistage TEC consists of four different sizes of thermoelectric modules and they are operated with an optimized current. Once the cold-part of the uppermost stage is reached at the no-load temperature, the current is successively supplied to the lower stages with a certain time interval; 25, 50 and 75 seconds. The results show the temperatures that can be ultimately reached at the cold-side of the lowermost stage are 197, 182 and 237 K, respectively. It can be concluded that the timing or total amount of the current fed to each thermoelectric module is the key parameter to determine the no-load temperature.

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

Experimental Study on the Performance of the Stirling Cryocooler with Nitrogen Refrigerant (질소냉매 스터링 냉동기의 성능에 관한 실험적 연구)

  • 김효봉;박성제;홍용주;염한길;고득용;김양훈;박종호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.67-70
    • /
    • 2002
  • The Stirling cryocooler with helium refrigerant has been widely used for the cooling of the infrared detector, and the alternatives of the helium in the Stirling cryocooler are nitrogen and hydrogen gas. In this study, the performance experiment of the small FPFD(Free Piston and Free Piston) type Stirling cooler and the moving coil type, dual acting linear compressor was performed when the nitrogen and helium is used for the working fluid The results show that the nitrogen refrigerant has small cooling capacity compared with the helium, but the performance characteristics of the linear compressor does not greatly changed.

  • PDF

Study of the Dependency on Operating Frequency of the Stirling Cryocooler (스터링 극저온 냉동기의 운전주파수 의존성에 관한 연구)

  • 홍용주;박성제;고득용;김효봉;김양훈;김종학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.63-66
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stilting cryocooler for the cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stirling cryocooler has maximum cooling capacity at the certain relation between operating frequency and natural frequency of the displacer and the operating frequency of the Stirling crycooler should be determined by natural frequency of the linear compressor and displacer.

  • PDF

The effect of the charging pressure and operating frequency in the Stirling Cryocooler (충전압력 및 작동주파수 특성 연구에 의한 스터링 냉동기 개발)

  • 박성제;홍용주;김효봉;고득용;김양훈;유병건;이기백
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.62-68
    • /
    • 2001
  • This paper presents manufacturing process and test results in the optimum pressure and operating frequency for the free piston free displacer(FPFD) Stirling cryocooler designed and manufactured by Korea Institute of Machinery &Materials (KIMM). FPFD Stirling cryocooler is currently under development uses opposed linear motors to drive opposed pistons . The performance of FPFD Stirling cryocooler is evaluated as a function fo charging pressure and operating frequency. In general as the operating frequency of the compressor is increaed but natural frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49K and cooling capacity of 0.5W at 7.2K.

  • PDF

Study of KIMM-E1 Stirling Cryocooler Performance with Different Charging pressure (충진압력에 따른 KIMM-E1 스터링 극저온 냉동기에 관한 연구)

  • 박성제;홍용주;고득용;김효봉;오군섭;염한길;김종학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.33-36
    • /
    • 2001
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). The FPFD Stirling cryocooler employs 1) the Stirling cycle for refrigeration, 2) linear motors for driving the cryocooler, 3) spring and gas support systems, and 4) fine gap for clearance seals. It is the most suitable design for a mechanical cryocooler utilized in night vision environment. The experimental results show KIMM-E1 Stirling cryocooler (with expander manufactured by KIMM) has the higher cooling power and faster response time at optimum charging pressure.

  • PDF