• Title/Summary/Keyword: Free ammonia

Search Result 217, Processing Time 0.038 seconds

Effect of high free ammonia concentration on microalgal growth and substrate uptake (폐수 내 고농도 free ammonia(FA)가 미세조류의 성장 및 기질제거에 미치는 영향 평가)

  • Kim, Eun-Ji;Cho, Jae Hyung;Noh, Kyung Ho;Nam, guisook;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.715-723
    • /
    • 2016
  • This study investigated the effect of high concentration of free ammonia on microalgal growth and substrate removal by applying real wastewater nitrogen ratio. To test of this, the conditions of free ammonia 1, 3, 6, 9, 12, 15 mg-N/L are compared. After 3 days of incubation, algal growth of Chlorella vulgaris and carbon removal rate are respectively lower in the reactors of FA 12, 15 mg-N/L compared to the others. This indicates that the high concentration of free ammonia, in this case, above 12 mg-N/L, has negative effect on algal growth and metabolic activity. Also, high concentration of free ammonia causes the proton imbalance, ammonium accumulation in algae and has toxicity for these reasons. So, we have to consider free ammonia in applying the microalgae to wastewater treatment system by the way of diluting wastewater or controlling pH and temperature.

아질산성 질소의 축적에 대한 용존 산소와 free ammonia의 영향 연구

  • Han, Dong-U;Lee, Su-Cheol;Lee, Nam-Hui;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.475-478
    • /
    • 2000
  • For an integrated nitrification-denitrification process, nitrite formation in the aerobic stage leads to big savings. Dissolved oxygen concentration, temperature, pH and free ammonia concentration have been meet for nitrite accumulation. Also their effects over the ammonia oxidizers and nitrite oxidizers have been studied. Dissolved oxygen limitation and free ammonia inhibition led to slow nitrification and nitrite build up. In this study batch kinetics of ammonium and nitrite oxidations were performed with free ammonia accumulated nitrifiers. From the results it is likely the nitrite oxidizers are inhibited by oxygen limitation rather than free ammonia.

  • PDF

Influence of FA and FNA to Microbial Community in Sequencing Batch Ammonium Partial Nitrification System (암모니아 부분산화 공정의 제어와 미생물 군집의 변화)

  • Ahn, Johwan
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.399-406
    • /
    • 2015
  • A sequencing batch reactor was operated under different pH conditions to see the influence of free ammonia (FA) and free nitrous acid (FNA) to microbial community on ammonium partial nitrification. Long-term influences of FA and FNA were evaluated by polymerase chain reaction-denaturing gradient gel electrophoresis and fluorescence in situ hybridization. Nitrite accumulation was successfully achieved at pH 8.2 and 6.3. The shifts in the microbial community were observed when influent ammonia concentration increased to 1 g $NH_4$-N/L at pH 8.2, and then when pH was dropped to 6.3. Both Nitrosomonas and Nitrosospira were selected during the startup of the reactor, and eventually became dominant members as ammonia-oxidizing bacteria. The results of molecular microbiological analysis strongly suggested that the composition of microbial community was changed according to the method used to control nitrite-oxidizing bacteria.

A Study on Ammonia Reforming Catalyst and Reactor Design for 10 kW Class Ammonia-Hydrogen Dual-Fuel Engine (10 kW 급 암모니아-수소 혼소엔진을 위한 암모니아 개질 촉매 및 반응기 설계에 관한 연구)

  • LEE, SANGHO;CHOI, YOUNG;PARK, CHEOLWOONG;KIM, HONGSUK;LEE, YOUNG DUK;KIM, YOUNG SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.4
    • /
    • pp.372-379
    • /
    • 2020
  • Ammonia-hydrogen dual-fuel engine is a way to reduce greenhouse gas emission because ammonia and hydrogen are carbon-free fuels. In ammonia-hydrogen dual-fuel engine, hydrogen is supplied to improve the combustion characteristic of ammonia. In this study, an ammonia reformer was developed to supply hydrogen for 10 kW class ammonia-hydrogen dual-fuel engine. Thermodynamic characteristic and catalyst were investigated for ammonia reforming. Heat transfer was important for high ammonia conversion of ammonia reformer. 99% of ammonia conversion was obtained when 10 LPM of ammonia and 610℃ of hot gas were supplied to the ammonia reformer.

Measurement of Ammonia Inhibition of Activated Sludge by DHA-INT (DHA-INT를 이용한 활성슬러지의 암모니아 저해도)

  • Lee, Sang-Min;Jung, Jin-Young;Chung, Yun-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.1969-1976
    • /
    • 2000
  • It is a time consuming work to identify the inhibition of unknown chemicals or industrial wastewater. Thus it is needed to establish a fast assay tool for finding a toxicant source. Biomass activity and ammonia inhibition were measured by DHAINT method. Ammonia inhibition tests were comprised of total ammonia inhibition and free ammonia inhibition. Those inhibitions were carried out by nitrifier and heterotroph each other with nitrifier inhibitor. The ammonia inhibition was proportional to an amount of total ammonia and pH increase. It meaned that a free ammonia played a key role for ammonia inhibition. however both total ammonia and free ammonia should be considered for an accurate assay of the ammonia inhibition. Nitrifier was more sensitive than heterotroph when the ammonia concentration above 3.000mg/L.

  • PDF

Analysis of Free Ammonia Inhibition of Nitrite Oxidizing Bacteria Using a Dissolved Oxygen Respirometer

  • Kim, Dong-Jin;Lee, Dong-Ig;Cha, Gi-Cheol;Keller, Jurg
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.125-130
    • /
    • 2008
  • Free ammonia ($NH_3$-N) inhibition of nitrite-oxidizing bacteria (NOB) has been widely studied for partial nitrification (or nitrite accumulation) and denitrification via nitrite ($NO_2^-$-N) as a low-cost treatment of ammonium containing wastewater. The literature on $NH_3$-N inhibition of NOB, however, shows disagreement about the threshold $NH_3$-N concentration and its degree of inhibition. In order to clarify the confusion, a simple and cheap respirometric method was devised to investigate the effect of free ammonia inhibition of NOB. Sludge samples from an autotrophic nitrifying reactor were exposed to various $NH_3$-N concentrations to measure the maximum specific nitrite oxidation rate ($\hat{K}_{NO}$) using a respirometer. NOB biomass was estimated from the yield values in the literature. Free ammonia inhibition of nitrite oxidizing bacteria was reversible and the specific nitrite oxidation rate ($K_{NO}$) decreased from 0.141 to 0.116, 0.100, 0.097 and 0.081 mg $NO_2^-$-N/mg NOB h, respectively, as the $NH_3$-N concentration increased from 0.0 to 1.0, 4.1, 9.7 and 22.9 mg/L. A nonlinear regression based on the noncompetitive inhibition mode gave an estimate of the Inhibition concentration ($K_I$) of free ammonia to be 21.3 mg $NH_3$-N/L. Previous studies gave $\hat{K}_{NO}$ of Nitrobacter and Nitrospira as 0.120 and 0.032 mg/mg VSS h. The free ammonia concentration which inhibits Nitrobacter was $30{\sim}50\;mg$ $NH_3$-N/L and Nitrospira was inhibited at $0.04{\sim}0.08\;mg$ $NH_3$-N/L. The results support the fact that Nitrobacter is the dominant NOB in the reactor. The variations in the reported values of free ammonia inhibition may be due to the different species of nitrite oxidizers present in the reactors. The respirometric method provides rapid and reliable analysis of the behavior and community of the nitrite oxidizing bacteria.

Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor (중공사막 접촉기를 이용한 암모니아 물질전달 모델링)

  • Oh, Dae-Yang;Jeong, Joo-Young;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.

Mitigation of Ammonia Dispersion with Mesh Barrier under Various Atmospheric Stability Conditions

  • Gerdroodbary, M. Barzegar;Mokhtari, Mojtaba;Bishehsari, Shervin;Fallah, Keivan
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.3
    • /
    • pp.125-136
    • /
    • 2016
  • In this study, the effects of the mesh barrier on the free dispersion of ammonia were numerically investigated under different atmospheric conditions. This study presents the detail and flow feature of the dispersion of ammonia through the mesh barrier on various free stream conditions to decline and limit the toxic danger of the ammonia. It is assumed that the dispersion of the ammonia occurred through the leakage in the pipeline. Parametric studies were conducted on the performance of the mesh barrier by using the Reynolds-averaged Navier-Stokes equations with realizable k-${\varepsilon}$ turbulence model. Numerical simulations of ammonia dispersion in the presence of mesh barrier revealed significant results in a fully turbulent free stream condition. The results clearly show that the flow behavior was found to be a direct result of mesh size and ammonia dispersion is highly influenced by these changes in flow patterns in downstream. In fact, the flow regime becomes laminar as flow passes through mesh barrier. According to the results, the mesh barrier decreased the maximum concentration of the ammonia gas and limited the risk zone (more than 500 ppm) lower than 2 m height. Furthermore, a significant reduction occurs in the slope of the upper boundary of $NH_3$ risk zone distribution at downstream when a mesh barrier is presented. Thus, this device highly restricts the leak distribution of ammonia in the industrial plan.

Community structure analysis of nitrifying biofilms by 16S rRNA targeted probe and fluorescence in situ hybridization (FISH)

  • Han, Dong-U;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.282-285
    • /
    • 2001
  • The microbial community structure and in situ spatial distribution of ammonia oxidizing and nitrite oxidizing bacteria in nitrifying biofilm of an upflow biological aerated filter system were investigated. The reactor had been continuously operated under high free ammonia concentration and low DO concentration for nitrite accumulation more than 2 years before the experiment. Fluorescence in situ hybridization

  • PDF