• Title/Summary/Keyword: Free Piston

Search Result 124, Processing Time 0.024 seconds

Performance Evaluation of a Crank-driven Compressor and Linear Compressor for a Household Refrigerator

  • Park, Minchan;Jung, Yoongho;Lee, Jaeyeol;Lee, Jaekeun;Ahn, Youngchull
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.5-12
    • /
    • 2017
  • With the difficulties in increasing the efficiency of conventional crank-driven compressors due to mechanical loss, compressor manufacturers have investigated new kinds of compressor such as a free piston compressor mechanism. This study investigates the energy efficiency of two different types of compressor for a household refrigerator. One is the conventional crank-driven compressor, and the other one is a linear compressor. The energy efficiencies of these compressors are evaluated. Experimental results show that the linear compressor has 10% lower power consumption than the brushless direct-current (BLDC) reciprocating compressor. The linear compressor demonstrates excellent energy efficiency by reducing the friction loss. Furthermore, a motor efficiency exceeding 90% is achieved by using a linear oscillating mechanism with a moving magnet. Additionally, the compressor stroke to piston diameter ratio of the oscillating piston in the linear compressor can be adjusted in order to modulate the cooling capacity of the compressor for improved system efficiency.

Analysis and Efficiency Control of Linear Compressor System for Refrigerator Driven by PWM Inverter (PWM인버터로 구동되는 냉장고용 선형압축기시스템의 특성해석 및 효율제어)

  • Son, Jang-Kyung;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1544-1549
    • /
    • 2013
  • Recently, the linear compressors with the free piston driven by the linear motor have widely attention in the cooling apparatus such as a refrigerator due to high efficiency. The method of using triacs as a linear motor drive is not satisfactory to improve the efficiency of the linear compressor. In this paper, the performance of the linear compressor using a PWM inverter such as the efficiency is investigated with the variations of both mechanical resonant frequency and electrical resonant frequency. The control loop for controlling both the piston stroke and efficiency is suggested. Through simulation and experimental studies, the performance of both the stroke and angle controls for improving the efficiency of the linear compressor is verified.

A Study on the Friction and Wear Property of Composite Piston Ring for Oil Free Air Compressor (무급유 공기압축기용 복합재료 피스턴링의 마찰마모 특성에 관한 연구)

  • Kim, Y.Z.;Jung, H.D.;Kim, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.766-771
    • /
    • 2000
  • This study is mainly concerned with friction and wear properties for the piston ring of non-lubricating air compressor which made of PTFE-polyimide composites. At the PTFE and polyimide alone mixture specimens, PTFE80%-polyimide20%, which shows the lowest men friction coefficient and specific wear rate at 0.94m/s sliding speed. At each of carbon, copper and oxide lopper mixed with PTFE80%-polyimide20%. In case of copper10%, at 0.94m/s sliding speed, the mean friction coefficient shows 0.087, which is the lowest value in all specimens. In case of the specific wear rate, copper30% specimen shows the lowest value of $2.537E-5(mm^3/Nm)$ in all specimens.

  • PDF

EFFECT OF THE SHAPE OF IMPINGEMENT PLATE ON THE VAPORIZATION AND FORMATION OF FUEL MIXTURE IN IMPINGING SPRAY

  • Kang, J.J.;Kim, D.W.;Choi, G.M.;Kim, D.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.585-593
    • /
    • 2006
  • The effect of the shape of the side wall on vaporization and fuel mixture were investigated for the impinging spray of a direct injection(DI) gasoline engine under a variety of conditions using the LIEF technique. The characteristics of the impinging spray were investigated under various configurations of piston cavities. To simulate the effect of piston cavity configurations and injection timing in an actual DI gasoline engine, the parameters were horizontal distance from the spray axis to side wall and vertical distance from nozzle tip to impingement plate. Prior to investigating the side wall effect, experiments on free and impinging sprays for flat plates were conducted and these results were compared with those of the side wall impinging spray. For each condition, the impingement plate was located at three different vertical distances(Z=46.7, 58.4, and 70 mm) below the injector tip and the rectangular side wall was installed at three different radial distances(R=15, 20, and 25 mm) from the spray axis. Radial propagation velocity from spray axis along impinging plate became higher with increasing ambient temperature. When the ambient pressure was increased, propagation speed reduced. High ambient pressures tended to prevent the impinging spray from the propagating radially and kept the fuel concentration higher near the spray axis. Regardless of ambient pressure and temperature fully developed vortices were generated near the side wall with nearly identical distributions, however there were discrepancies in the early development process. A relationship between the impingement distance(Z) and the distance from the side wall to the spray axis(R) was demonstrated in this study when R=20 and 25 mm and Z=46.7 and 58.4 mm. Fuel recirculation was achieved by adequate side wall distance. Fuel mixture stratification, an adequate piston cavity with a shorter impingement distance from the injector tip to the piston head should be required in the central direct injection system.

A Study on the Concrete Extrusion Method for Precision FCP Fabrication (정밀한 FCP 제작을 위한 콘크리트 압출 방식 연구)

  • Kim, Hye-Kwon;Kim, Ji-Hye;Kim, Sungjin;Lee, Donghoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.133-134
    • /
    • 2023
  • Free-form buildings have a curved shape and are composed of geometric shapes, which require high precision. Therefore, this study proposed a new extrusion method, a piston method, that improves the precision of FCP by automatically extruding a predetermined amount of concrete by improving the aforementioned limitations. The technology to extrude a predetermined amount of concrete by applying pistons is expected to shorten construction period and increase economic efficiency by improving the precision and productivity of free-form panels.

  • PDF

The Numerical Study on the Flow Characteristics in Two-Dimensional Moonpool in Waves

  • Lee, Sang-Min;Im, Nam-Kyun
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.443-450
    • /
    • 2014
  • The objective of this study is to examine the nonlinear fluid characteristics near and inside a moonpool in various sea conditions. We estimate the flow of the free surface in a moonpool taking into account the viscosity effect and the hydrodynamic forces that affects a moonpool and hull through CFD calculations. The comparison of horizontal forces per wave length shows that the hydrodynamic force is greater for the long wave length than short wave length, and the greatest hydrodynamic force acts on the moonpool when the wave length is equal to the ship's length. The horizontal force decreases as the wave amplitude decreases, and the hydrodynamic force acting on the moonpool in ${\lambda}=LBP$ is 10 times that in ${\lambda}=LBP/3$. The free surface demonstrates the piston mode, in which it oscillates up and down while remaining essentially flat, and the rise of the free surface level increases as the wave length increases. We can assume that the hydrodynamic force acting on the moonpool increases owing to the effect of a strong vortex for ${\lambda}=LBP$ and owing to the rise of the free surface level for ${\lambda}=LBP{\times}2$.

Design of the Linear Compressor Stirling Cryocooler (Linear compressor 스터링 냉동기 설계에 관한 연구)

  • 박성제;고득용;홍용주;김효봉
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.81-84
    • /
    • 2000
  • This paper presents operating process and design method on the linear compressor Stirling cryocooler for cooling infrared detector. The free piston-type Stirling cryocooler, which applies 1) the Stirling cycle for refrigeration, 2) linear motors for driving, 3) flexure bearings for support systems, and 4) fine gap for clearance seals, is the most suitable design for a mechanical cryocooler utilized in a night vision environment.

  • PDF

A Novel Method for Calculating the Stroke of LPMSM for Driving Linear Compressor Using High Pass Filter (고역필터를 사용한 선형압축기 구동용 LPMSM의 새로운 스트로크 계산 기법)

  • Ahn, Jung-Ryol;Lee, Hong-Hee;Kim, Heung-Gun;Nho, Eui-Cheol;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Linear compressors with a free piston driven by a linear motor are widely attention in the cooling apparatus such as refrigerator due to the high efficiency The stroke of piston in the linear compressor driven by LPMSM (Linear Permanent-Magnet Synchronous Motor) can be obtained from Integrating the input voltage and current of LPMSM, but it may be diverged due to dc components in the voltage and current. The strategy to prevent the divergence of stroke using both the high-pass filter and do offset compensation was suggested. The equations for the magnitude and phase of the stroke and also dc offset including the stroke are derived as a function of the cut-off frequency of HPF. The accurate stroke of a piston can be calculated by compensating for dc offset. The performance of the newly developed stroke calculation scheme has been verified by experimentally on a linear compressor drive system, where the control was implemented by a 16-bit DSP.

A study on the Characteristics of linear compressor drive systems (선형 압축기 구동시스템 특성에 관한 연구)

  • Ahn J.R.;Chun T.W.;Lee H.H.;Kim H.G.;Nho E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.424-429
    • /
    • 2003
  • A reciprocating compressor with a rotary motor used in a refrigerator has low efficiency, because it has the large mechanical losses due to the crank mechanism. The linear compressor which has the free piston driven by a linear motor, was developed to increase the efficiency of compressor by reducing mechanical losses. The TRIAC has been widely used for controlling the piston, because it has simple structure. However, as it is able to control only stator voltage, it is very difficult to obtain good efficiency. Recently, PWM inverter which is able to control the voltage as well as the frequency, is applied to linear compressor drive system to overcome above problem. In this paper, the variations for efficiency and power factor of linear compressor are investigated by changing both the mechanical resonant frequency and electrical resonant frequency of linear compressor, and also the inverter frequency The optimum relationships between both resonant frequencies and the inverter frequency is derived in order to obtain the maximum efficiency and also good power factor.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.