• 제목/요약/키워드: Fourier Transform Infrared Spectroscopy

검색결과 966건 처리시간 0.025초

Preparation and Characterization of Suvarna Bhasma Parada Marit - Characterization of Suvarna Bhasma Parada Marit -

  • Thakur, Kapil;Gudi, Ramacharya;Vahalia, Mahesh;Shitut, Shekhar;Nadkarni, Shailesh
    • 대한약침학회지
    • /
    • 제20권1호
    • /
    • pp.36-44
    • /
    • 2017
  • Objectives: The goal of this study was to characterize Suvarna Bhasma Parada Marit by using the Ayurvedic test parameters, physico-chemical tests, and various instrumentation techniques. Methods: Suvarna Bhasma, an Ayurvedic formulation manufactured as per Bharat Bhaishajya Ratnakar 5/8357 (BBR), has been studied using various instrumentation techniques: X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDAX), laser particle size distribution (PSD) analysis, fourier transform infrared spectroscopy (FT-IR), and atomic absorption spectroscopy (AAS), and physico-chemical parameters, such as the loss on drying (LOD), loss on ignition (LOI), and acid insoluble Ash (AIA) were determined. In addition, Ayurvedic tests, such as Rekhapurnatva (enterable in the furrows of the fingers), Varitaratwa (floatable over water), Nirdhoomta (smokeless), Dantagre Kach-Kach (gritty particle feeling between the teeth), were performed. Results: The XRD study showed Suvarna Bhasma to be crystalline in nature and to contain more than 98% gold. The mean size of the gold crystallites was less than 10 microns, and the morphology was globular and irregular. Suvarna Bhasma contains gold as its single and major element, with EDAX and FT-IR spectra showing that it is more than 98% pure gold. The moisture content (LOD) is less than 0.5%, the LOI is less than 2%, and the AIA is not less than 95%. The Ayurvedic tests, as specified above, helped to confirm the quality of Suvarna bhasma prepared as per the text reference (BBR). Conclusion: This chemical characterization of Suvarna Bhasma performed in this study by using modern instrumentation techniques will be helpful in understanding its pharmacological actions and will help in establishing quality protocols and specifications to substantiate the safety, efficacy & quality of Suvarna Bhasma.

광감성 폴리비닐플루오로신나메이트의 액정 배향에 관한 연구 (Studies of Liquid Crystal Alignment on the Photosensitive Polyvinylfluorocinnamate)

  • 김동수;안원술;하기룡
    • 폴리머
    • /
    • 제31권5호
    • /
    • pp.393-398
    • /
    • 2007
  • 편광 푸리에 변환 적외선 분광법(polarized fourier transform infrared spectroscopy)과 자외선 분광법(ultraviolet spectroscopy)을 이용하여 액정 디스플레이 (liquid crystal display, LCD)의 배향막으로 사용 가능한 Polyvulylfluoroclnnamate(PVCN-F) 필름의 편광 자외선(Polarized UV, PUV) 조사 및 러빙에 따른 액정의 배향 메커니즘에 관한 연구를 수행하였다. UV의 조사시간이 증가함에 따라 PVCN-F cinnamoyl group의 C=C기들의 cycloaddition 반응으로 인하여 $1638cm^{-1}$에서 나타나는 vinylene -C=C- FT-IR 흡수 피크들의 면적이 감소하고, $1712cm^{-1}$에서 나타나는 conjugated C=O 신축진동에 의한 피크가 nonconjugated C=O 신축진동 피크인 $1734cm^{-1}$로 이동함을 확인하였다. 또한 PUV가 조사된 PVCN-F 배향막을 사용하여 제조된 액정 셀에서는 조사된 PUV의 극성 방향과 수직으로 액정이 배향함을 확인하였고, 러빙 방법으로 제조된 PVCN-F 배향막을 사용한 액정 셀에서는 액정이 러빙 방향과 수평으로 배향됨을 dichroic dye(이색성 염료)의 첨가 없이 편광 FT-IR 스팩트럼을 사용하여 확인하였다.

실리카 나노입자 표면에 결합된 아미노기와 Glycidyl Methacrylate의 반응에 관한 분광학적 연구 (Spectroscopic Studies on the Reaction between Amino Groups on Silica Nanoparticle Surface and Glycidyl Methacrylate)

  • 이상미;하기룡
    • 폴리머
    • /
    • 제37권6호
    • /
    • pp.777-783
    • /
    • 2013
  • 본 연구에서는 실리카 나노입자를 dipodal 형태의 bis[3-(trimethoxysilyl)propyl]amine(BTMA) 실란 커플링제로 실리카 표면을 개질한 후, glycidyl methacrylate(GMA)로 표면 처리를 하여 실리카에 결합된 BTMA의 N-H기와 GMA의 epoxide기의 개환 반응에 의하여 실리카 표면에 중합용 methacrylate기를 도입하는 연구를 수행하였다. 반응시간, 반응온도 및 투입하는 GMA의 농도 변화가 BTMA의 N-H기와 GMA의 epoxide기 사이의 반응에 미치는 영향을 Fourier transform infrared spectroscopy(FTIR), elemental analysis(EA) 및 고체상태 $^{13}C$ cross-polarization magic angle spinning(CP/MAS), nuclear magnetic resonance spectroscopy(NMR)법을 사용하여 분석하였다. BTMA로 개질된 실리카를 GMA로 처리하면 실리카 입자에 결합되어 있는 BTMA의 N-H기와 GMA의 epoxide기가 열리면서 상호 반응이 일어났으며, 실험한 조건에서는 반응시간, 반응온도 및 투입하는 GMA 농도가 증가할수록 실리카 표면에 도입되는 methacrylate기가 증가함을 확인하였다.

SiON 박막의 광학적 특성에 대한 연구 (The study of SiON thin film for optical properlies)

  • 김도형;임기주;김기현;김현석;김상식;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.247-250
    • /
    • 2001
  • We studied optical properties of SiON thin-film in the applications of optical waveguide. SiON thin-film was grown in 300$^{\circ}C$ by PECVD(plasma enhanced chemical vapor deposition) system. The change of SiON thin-film composition and refractive Index was studied as a function of varying NH$_3$ gas flow rate. As NH$_3$ gas flow rate was increased, Quantity of N and refractive index were increased at the same time. By the results, we could form the SiON thin-film to use of a waveguide with refractive index of 1.6. We analyzed the conditions of the thin-film with FTIR(fourier transform infrared) and OES(optical emission spectroscopy). N-H bonding(3390cm$\^$-1/) can be removed by thermal annealing. And we could observe the SiH bonding state and quantity by OES analysis in SiH$_4$

  • PDF

Reagentless Determination of Human Serum Components Using Infrared Absorption Spectroscopy

  • Hahn, Sang-Joon;Yoon, Gil-Won;Kim Gun-Shik;Park Seung-Han
    • Journal of the Optical Society of Korea
    • /
    • 제7권4호
    • /
    • pp.240-244
    • /
    • 2003
  • Simultaneous determination of concentrations for four major components in human blood serum was investigated using a Fourier-transform mid-infrared spectroscopy. Infrared spectra of human blood serum were measured in 8.404 ∼ 10.25 ${\mu}m$ range where the highest absorption peaks of glucose are located. A partial least square (PLS) algorithm was utilized to establish a calibration model for determining total protein, albumin, globulin and glucose levels which are commonly measured metabolites. The standard error of cross validation obtained from our multivariate calibration model was 0.24 g/dL for total protein, 0.15 g/dL for albumin, 0.17 g/dL for globulin, and 6.68 mg/dL for glucose, which are comparable with or meet the criteria for clinical use. The results indicate that the infrared absorption spectroscopy can be used to predict the concentrations of clinically important metabolites without going through a chemical process with a reagent.

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons by Near Infrared Spectroscopy using a Partial Least Squares Regression

  • Nam, Jae-Jak;Lee, Sang-Hak;Park, Ju-Eun
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1276-1276
    • /
    • 2001
  • Polycyclic aromatic hydrocarbons(PAHs) are widely distributed in the environment and are often implicated as potential carcinogens. The chromatographic methods of detection and quantitative determination of PAHs in environmental samples are costly, time consuming, and do not account for all kinds of PAHs. This work describes a quantitative spectroscopic method for the analysis of mixtures of eight PAHs using multivariate calibration models for Fourier transform near infrared(FT-NIR) spectral data. The NIR spectra of mixtures of PAHs (anthracene, pyrene, 1,2-benzanthracene, perylene, chrysene, benzo(a)pyrene, 1-methylanthracene and benzo(ghi)perylene) were measured in the wavelength range from 1100 nm to 2500 nm. The spectral data were processed using a partial least squares regression. We have studied the spectral characteristics of NIR spectra of mixtures of PAHs. It was possible to determine each PAM used in this study at the environmental level(mg L-1) in the laboratory samples. Further development may lead to the rapid determination of more PAHs in typical environmental samples.

  • PDF

Fourier 변환 적외선 분광분석법에 의한 딸기 과육의 성숙도 측정 가능성 (Feasibility of Determining the Ripeness of Strawberry Fruit Flesh by Fourier Transform Infrared Spectroscopy)

  • 민성란;곽철원;김석원;정원중;정화지;최필선;고석민;박상규;정회일;유장렬
    • Journal of Plant Biotechnology
    • /
    • 제33권4호
    • /
    • pp.277-281
    • /
    • 2006
  • Fourier transform - infrared spectroscopy (FT-IR) provides biochemical profiles containing overlapping signals from a majority of the compounds that are present when whole cell extracts are analyzed. We attempted to determine the ripeness of strawberry fruit flesh by FT-IR. Fruit ripeness was divided into four developmental stages based on fruit skin color: 'yellow-green', 'pink-green', 'pink', and 'red' stages. Principal component analysis of FT-IR data of inside fruit flesh extracts clustered samples of four different developmental stages into three discrete groups: (1) 'yellow-green' group, (2) 'pink-green' group, and (3) 'pink' and 'red' group. The most remarkable difference between four different developmental stages was found in the carbohydrate fingerprint region $(1,000-1,100cm^{-1})$ of the FT-IR spectrum, indicating that differences in carbohydrate compounds represented the ripeness of strawberry fruit. Overall results indicate that FT-IR in combination with PCA enables discrimination of the ripeness of strawberry fruit flesh.

수동형 퓨리에변환 적외선 분광기의 잡음등가온도지수 (Noise Equivalent Differential Temperature of Passive FTIR Sensor System)

  • 강영일;박병황;최명진;홍대식;최수;김동환;박도현
    • 한국군사과학기술학회지
    • /
    • 제14권2호
    • /
    • pp.161-166
    • /
    • 2011
  • The passive open-path Fourier-Transform-Infrared system was implemented for the toxic gas monitoring. Noise Equivalent Differential Temperature(NEDT) was investigated as a system performance evaluation figure and analyzed numerically with the designed parameters. Calculated NEDT was compared with the experimental value in the wavelength region of $700{\sim}1400cm^{-1}^$. The minimum detectable gas concentration was estimated from the obtained NEDT at the absorption wavelength of $SF_6$.

Quantitative analysis of glycerol concentration in red wine using Fourier transform infrared spectroscopy and chemometrics analysis

  • Joshi, Rahul;Joshi, Ritu;Amanah, Hanim Zuhrotul;Faqeerzada, Mohammad Akbar;Jayapal, Praveen Kumar;Kim, Geonwoo;Baek, Insuck;Park, Eun-Sung;Masithoh, Rudiati Evi;Cho, Byoung-Kwan
    • 농업과학연구
    • /
    • 제48권2호
    • /
    • pp.299-310
    • /
    • 2021
  • Glycerol is a non-volatile compound with no aromatic properties that contributes significantly to the quality of wine by providing sweetness and richness of taste. In addition, it is also the third most significant byproduct of alcoholic fermentation in terms of quantity after ethanol and carbon dioxide. In this study, Fourier transform infrared (FT-IR) spectroscopy was employed as a fast non-destructive method in conjugation with multivariate regression analysis to build a model for the quantitative analysis of glycerol concentration in wine samples. The samples were prepared by using three varieties of red wine samples (i.e., Shiraz, Merlot, and Barbaresco) that were adulterated with glycerol in concentration ranges from 0.1 to 15% (v·v-1), and subjected to analysis together with pure wine samples. A net analyte signal (NAS)-based methodology, called hybrid linear analysis in the literature (HLA/GO), was applied for predicting glycerol concentrations in the collected FT-IR spectral data. Calibration and validation sets were designed to evaluate the performance of the multivariate method. The obtained results exhibited a high coefficient of determination (R2) of 0.987 and a low root mean square error (RMSE) of 0.563% for the calibration set, and a R2 of 0.984 and a RMSE of 0.626% for the validation set. Further, the model was validated in terms of sensitivity, selectivity, and limits of detection and quantification, and the results confirmed that this model can be used in most applications, as well as for quality assurance.

백미의 총 식이섬유함량 예측 모델 개발을 위한 퓨리에변환 근적외선분광계의 적용 (Application of Fourier Transform Near-Infrared Spectroscopy for Prediction Model Development of Total Dietary Fiber Content in Milled Rice)

  • 이진철;윤연희;은종방
    • 한국식품저장유통학회지
    • /
    • 제12권6호
    • /
    • pp.608-612
    • /
    • 2005
  • 친환경적이면서 신속한 비파괴 분석방법인 FT-NIR를 이용하여 백미의 총식이섬유(TDF)함량 예측모델을 개발하였다. 백미는 국내산으로 전남지방에서 재배된 47개 품종과, 시중 유통 중인 13개 브랜드 미에 대해서 AOAC 방법에 준한 효소법에 의해 TDF 함량을 분석하였다. 습식 분석된 TDF함량의 범위는 $1.17-1.92\%$ 이었다. FT-NIR로 측정된 스펙트럼의 검량식은 빛의 산란 효과를 최소화하기 위해 수학적 처리를 하였고, 몇 개의 특정 파장이 아닌 전 파장 영역(1,000-2,500 nm)에 대해서 PLS법으로 작성하였다. 얻어진 검량식의 정확도는 상관계수(r), SEE 및 SEP로 확인하였다. 백미 중 총 식이섬유 함량에 대한 회귀분석을 행한 결과, 검량식의 r은 0.9705, SEE는 0.0464, 검증식의 bias는 -0.0006, SEP가0.0604로 측정 정확도가 우수하여 실제 적용이 가능함을 보여주었다.