• Title/Summary/Keyword: Fourier Transform Infrared Spectroscopy

Search Result 971, Processing Time 0.027 seconds

Preparation and Characterization of Suvarna Bhasma Parada Marit - Characterization of Suvarna Bhasma Parada Marit -

  • Thakur, Kapil;Gudi, Ramacharya;Vahalia, Mahesh;Shitut, Shekhar;Nadkarni, Shailesh
    • Journal of Pharmacopuncture
    • /
    • v.20 no.1
    • /
    • pp.36-44
    • /
    • 2017
  • Objectives: The goal of this study was to characterize Suvarna Bhasma Parada Marit by using the Ayurvedic test parameters, physico-chemical tests, and various instrumentation techniques. Methods: Suvarna Bhasma, an Ayurvedic formulation manufactured as per Bharat Bhaishajya Ratnakar 5/8357 (BBR), has been studied using various instrumentation techniques: X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDAX), laser particle size distribution (PSD) analysis, fourier transform infrared spectroscopy (FT-IR), and atomic absorption spectroscopy (AAS), and physico-chemical parameters, such as the loss on drying (LOD), loss on ignition (LOI), and acid insoluble Ash (AIA) were determined. In addition, Ayurvedic tests, such as Rekhapurnatva (enterable in the furrows of the fingers), Varitaratwa (floatable over water), Nirdhoomta (smokeless), Dantagre Kach-Kach (gritty particle feeling between the teeth), were performed. Results: The XRD study showed Suvarna Bhasma to be crystalline in nature and to contain more than 98% gold. The mean size of the gold crystallites was less than 10 microns, and the morphology was globular and irregular. Suvarna Bhasma contains gold as its single and major element, with EDAX and FT-IR spectra showing that it is more than 98% pure gold. The moisture content (LOD) is less than 0.5%, the LOI is less than 2%, and the AIA is not less than 95%. The Ayurvedic tests, as specified above, helped to confirm the quality of Suvarna bhasma prepared as per the text reference (BBR). Conclusion: This chemical characterization of Suvarna Bhasma performed in this study by using modern instrumentation techniques will be helpful in understanding its pharmacological actions and will help in establishing quality protocols and specifications to substantiate the safety, efficacy & quality of Suvarna Bhasma.

Studies of Liquid Crystal Alignment on the Photosensitive Polyvinylfluorocinnamate (광감성 폴리비닐플루오로신나메이트의 액정 배향에 관한 연구)

  • Kim, Dong-Soo;Ahn, Won-Sool;Ha, Ki-Ryong;Buluy, O.;Reznikov, Yu.
    • Polymer(Korea)
    • /
    • v.31 no.5
    • /
    • pp.393-398
    • /
    • 2007
  • We studied the mechanism of liquid crystal alignment on polyvinylfluorocinnamate (PVCN-F) films which were irradiated by UV using polarized fourier transform infrared (FT-IR) spectroscopy and ultraviolet/visible (UV/Vis) spectroscopy. UV irradiation of PVCN-F films caused decrease of vinylene -C=C- stretching peak area at $1638cm^{-1}$ and shift of conjugated C:0 stretching vibration at $1712cm^{-1}\;to\;1734cm^{-1}$ which is caused by nonconjugated C=O stretching nitration. To study the orientation direction of 5CB liquid crystal (LC) molecules in the liquid crystal cell with PUV irradiation, rubbing treatment or without any treatment on the PVCN-F alignment layer, we used polarized FT-IR dichroism technique. We successfully measured 5CB LC alignment directions, which are perpendicular to the irradiated PUV polarization direction and parallel to the rubbing direction in the liquid crystal cell without using dichroic dyes.

Spectroscopic Studies on the Reaction between Amino Groups on Silica Nanoparticle Surface and Glycidyl Methacrylate (실리카 나노입자 표면에 결합된 아미노기와 Glycidyl Methacrylate의 반응에 관한 분광학적 연구)

  • Lee, Sangmi;Ha, KiRyong
    • Polymer(Korea)
    • /
    • v.37 no.6
    • /
    • pp.777-783
    • /
    • 2013
  • We used dipodal type bis[3-(trimethoxysilyl)propyl]amine (BTMA) silane coupling agent to modify silica nanoparticles to introduce secondary amino groups on the silica surface. These grafted N-H groups were reacted with glycidyl methacrylate (GMA) to introduce polymerizable methacrylate groups on the silica surface. After modification reaction, we used several analytical techniques such as Fourier transform infrared spectroscopy (FTIR), elemental analysis (EA) and solid state $^{13}C$ cross-polarization magic angle spinning (CP/MAS) nuclear magnetic resonance spectroscopy (NMR) to analyze the effects of reaction time, reaction temperature and used GMA concentration on the modification degree between N-H groups on the silica surface and epoxide groups of GMA. We found increased introduction of methacrylate groups on the silica surface by ring opening reaction of epoxide groups of GMA with N-H groups on BTMA treated silica with increased reaction time, reaction temperature and used GMA concentration within our experimental conditions.

The study of SiON thin film for optical properlies (SiON 박막의 광학적 특성에 대한 연구)

  • 김도형;임기주;김기현;김현석;김상식;성만영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.247-250
    • /
    • 2001
  • We studied optical properties of SiON thin-film in the applications of optical waveguide. SiON thin-film was grown in 300$^{\circ}C$ by PECVD(plasma enhanced chemical vapor deposition) system. The change of SiON thin-film composition and refractive Index was studied as a function of varying NH$_3$ gas flow rate. As NH$_3$ gas flow rate was increased, Quantity of N and refractive index were increased at the same time. By the results, we could form the SiON thin-film to use of a waveguide with refractive index of 1.6. We analyzed the conditions of the thin-film with FTIR(fourier transform infrared) and OES(optical emission spectroscopy). N-H bonding(3390cm$\^$-1/) can be removed by thermal annealing. And we could observe the SiH bonding state and quantity by OES analysis in SiH$_4$

  • PDF

Reagentless Determination of Human Serum Components Using Infrared Absorption Spectroscopy

  • Hahn, Sang-Joon;Yoon, Gil-Won;Kim Gun-Shik;Park Seung-Han
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.240-244
    • /
    • 2003
  • Simultaneous determination of concentrations for four major components in human blood serum was investigated using a Fourier-transform mid-infrared spectroscopy. Infrared spectra of human blood serum were measured in 8.404 ∼ 10.25 ${\mu}m$ range where the highest absorption peaks of glucose are located. A partial least square (PLS) algorithm was utilized to establish a calibration model for determining total protein, albumin, globulin and glucose levels which are commonly measured metabolites. The standard error of cross validation obtained from our multivariate calibration model was 0.24 g/dL for total protein, 0.15 g/dL for albumin, 0.17 g/dL for globulin, and 6.68 mg/dL for glucose, which are comparable with or meet the criteria for clinical use. The results indicate that the infrared absorption spectroscopy can be used to predict the concentrations of clinically important metabolites without going through a chemical process with a reagent.

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons by Near Infrared Spectroscopy using a Partial Least Squares Regression

  • Nam, Jae-Jak;Lee, Sang-Hak;Park, Ju-Eun
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1276-1276
    • /
    • 2001
  • Polycyclic aromatic hydrocarbons(PAHs) are widely distributed in the environment and are often implicated as potential carcinogens. The chromatographic methods of detection and quantitative determination of PAHs in environmental samples are costly, time consuming, and do not account for all kinds of PAHs. This work describes a quantitative spectroscopic method for the analysis of mixtures of eight PAHs using multivariate calibration models for Fourier transform near infrared(FT-NIR) spectral data. The NIR spectra of mixtures of PAHs (anthracene, pyrene, 1,2-benzanthracene, perylene, chrysene, benzo(a)pyrene, 1-methylanthracene and benzo(ghi)perylene) were measured in the wavelength range from 1100 nm to 2500 nm. The spectral data were processed using a partial least squares regression. We have studied the spectral characteristics of NIR spectra of mixtures of PAHs. It was possible to determine each PAM used in this study at the environmental level(mg L-1) in the laboratory samples. Further development may lead to the rapid determination of more PAHs in typical environmental samples.

  • PDF

Feasibility of Determining the Ripeness of Strawberry Fruit Flesh by Fourier Transform Infrared Spectroscopy (Fourier 변환 적외선 분광분석법에 의한 딸기 과육의 성숙도 측정 가능성)

  • Min, Sung-Ran;Kwak, Chul-Won;Kim, Suk-Weon;Jeong, Won-Joong;Chung, Hwa-Jee;Choi, Pil-Son;Ko, Suk-Min;Park, Sang-Kyu;Chung, Hoe-Il;Liu, Jang, R.
    • Journal of Plant Biotechnology
    • /
    • v.33 no.4
    • /
    • pp.277-281
    • /
    • 2006
  • Fourier transform - infrared spectroscopy (FT-IR) provides biochemical profiles containing overlapping signals from a majority of the compounds that are present when whole cell extracts are analyzed. We attempted to determine the ripeness of strawberry fruit flesh by FT-IR. Fruit ripeness was divided into four developmental stages based on fruit skin color: 'yellow-green', 'pink-green', 'pink', and 'red' stages. Principal component analysis of FT-IR data of inside fruit flesh extracts clustered samples of four different developmental stages into three discrete groups: (1) 'yellow-green' group, (2) 'pink-green' group, and (3) 'pink' and 'red' group. The most remarkable difference between four different developmental stages was found in the carbohydrate fingerprint region $(1,000-1,100cm^{-1})$ of the FT-IR spectrum, indicating that differences in carbohydrate compounds represented the ripeness of strawberry fruit. Overall results indicate that FT-IR in combination with PCA enables discrimination of the ripeness of strawberry fruit flesh.

Noise Equivalent Differential Temperature of Passive FTIR Sensor System (수동형 퓨리에변환 적외선 분광기의 잡음등가온도지수)

  • Kang, Young-Il;Park, Byeong-Hwang;Choi, Myung-Jin;Hong, Dea-Sik;Choi, Soo;Kim, Dong-Hwan;Park, Do-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.161-166
    • /
    • 2011
  • The passive open-path Fourier-Transform-Infrared system was implemented for the toxic gas monitoring. Noise Equivalent Differential Temperature(NEDT) was investigated as a system performance evaluation figure and analyzed numerically with the designed parameters. Calculated NEDT was compared with the experimental value in the wavelength region of $700{\sim}1400cm^{-1}^$. The minimum detectable gas concentration was estimated from the obtained NEDT at the absorption wavelength of $SF_6$.

Quantitative analysis of glycerol concentration in red wine using Fourier transform infrared spectroscopy and chemometrics analysis

  • Joshi, Rahul;Joshi, Ritu;Amanah, Hanim Zuhrotul;Faqeerzada, Mohammad Akbar;Jayapal, Praveen Kumar;Kim, Geonwoo;Baek, Insuck;Park, Eun-Sung;Masithoh, Rudiati Evi;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.2
    • /
    • pp.299-310
    • /
    • 2021
  • Glycerol is a non-volatile compound with no aromatic properties that contributes significantly to the quality of wine by providing sweetness and richness of taste. In addition, it is also the third most significant byproduct of alcoholic fermentation in terms of quantity after ethanol and carbon dioxide. In this study, Fourier transform infrared (FT-IR) spectroscopy was employed as a fast non-destructive method in conjugation with multivariate regression analysis to build a model for the quantitative analysis of glycerol concentration in wine samples. The samples were prepared by using three varieties of red wine samples (i.e., Shiraz, Merlot, and Barbaresco) that were adulterated with glycerol in concentration ranges from 0.1 to 15% (v·v-1), and subjected to analysis together with pure wine samples. A net analyte signal (NAS)-based methodology, called hybrid linear analysis in the literature (HLA/GO), was applied for predicting glycerol concentrations in the collected FT-IR spectral data. Calibration and validation sets were designed to evaluate the performance of the multivariate method. The obtained results exhibited a high coefficient of determination (R2) of 0.987 and a low root mean square error (RMSE) of 0.563% for the calibration set, and a R2 of 0.984 and a RMSE of 0.626% for the validation set. Further, the model was validated in terms of sensitivity, selectivity, and limits of detection and quantification, and the results confirmed that this model can be used in most applications, as well as for quality assurance.

Application of Fourier Transform Near-Infrared Spectroscopy for Prediction Model Development of Total Dietary Fiber Content in Milled Rice (백미의 총 식이섬유함량 예측 모델 개발을 위한 퓨리에변환 근적외선분광계의 적용)

  • Lee Jin-Cheol;Yoon Yeon-Hee;Eun Jong-Bang
    • Food Science and Preservation
    • /
    • v.12 no.6
    • /
    • pp.608-612
    • /
    • 2005
  • Fourier transform-near infrared (FT-NIR) spectroscopy is a simple, rapid, non-destructive technique which can be used to make quantitative analysis of chemical composition in grain. An interest in total dietary fiber (TDF) of grain such as rice has been increased due to its beneficial effects for health. Since measuring methods for TDF content were highly depending on experimental technique and time consumptions, the application of FT-NIR spectroscopy to determine TDF content in milled rice. Results of enzymatic-gravimetric method were $1.17-1.92\%$ Partial least square (PLS) regression on raw NIR spectra to predict TDF content was developed Accuracy of prediction model for TDF content was certified for regression coefficient (r), standard error of estimation (SEE) and standard error of prediction (SEP). The r, SEE and SEP were 0.9705, 0.0464, and 0.0604, respectively. The results indicated that FT-NIR techniques could be very useful in the food industry and rice processing complex for determination of TDF in milled rice on real time analysis.