• Title/Summary/Keyword: Four-Quadrant Operation

Search Result 39, Processing Time 0.037 seconds

Improvement of the amplification gain for a propulsion drives of an electric vehicle with sensor voltage and mechanical speed control

  • Negadi, Karim;Boudiaf, Mohamed;Araria, Rabah;Hadji, Lazreg
    • Smart Structures and Systems
    • /
    • v.29 no.5
    • /
    • pp.661-675
    • /
    • 2022
  • In this paper, an electric vehicle drives with efficient control and low cost hardware using four quadrant DC converter with Permanent Magnet Direct Current (PMDC) motor fed by DC boost converter is presented. The main idea of this work is to improve the energy efficiency of the conversion chain of an electric vehicle by inserting a boost converter between the battery and the four quadrant-DC motor chopper assembly. Consequently, this method makes it possible to maintain the amplification gain of the 4 quadrant chopper constant regardless of the battery voltage drop and even in the presence of a fault in the battery. One of the most important control problems is control under heavy uncertainty conditions. The higher order sliding mode control technique is introduced for the adjustment of DC bus voltage and mechanical motor speed. To implement the proposed approach in the automotive field, experimental tests were carried out. The performances obtained show the usefulness of this system for a better energy management of an electric vehicle and an ideal control under different operating conditions and constraints, mostly at nominal operation, in the presence of a load torque, when reversing the direction of rotation of the motor speed and even in case of battery chamber failure. The whole system has been tested experimentally and its performance has been analyzed.

Study on Choice Attributes for Low-Cost Carriers Using IPA (저가항공사 선택속성 IPA분석 연구)

  • Park, Young Sik
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.4
    • /
    • pp.112-118
    • /
    • 2013
  • Air travel demand has recently been growing and establishment and operation of low-cost carriers have been increased. Against this backdrop, low-cost carriers need to figure out diversified customer demand for low-cost carriers and ways to maximize marketing efficiency before applying it to the field so that they can attain superiority to large carriers in increased intensified competition. Low-cost carriers need to be differentiated from other carriers for the purpose of improving profits. Toward this end, this study conducted analysis on importance and satisfaction with carrier choice using IPA with regard to low-cost carrier customers. In conclusion, the paper accurately examined advantages and disadvantages of low-cost carriers compared to general carriers based on results of IPA analysis and suggested managerial strategies to enhance competitiveness based on division into four parts including maintenance and enforcement (1st quadrant, Delay compensation, Booking rapidity, Check rapidity, Crew service, refund service, baggage service, punctuality, transit services, airlines images), concentrated improvement (2nd quadrant, price, Convenience of seat), passive administration (3rd quadrant, Boarding service, cabin cleanliness, flight schedule, whether local crew on board, meal service, in-flight entertainment service), and enhanced satisfaction (4th quadrant, duty-free service, Variety of routes), so that practical suggestions could be presented to employees working in the field.

Development of Algorithms for Four-quadrant Gate System and Obstacle Detection Systems at Crossings (철도건널목 지장물·진입위반차량 검지시스템 및 4분할 차단 알고리즘 개발)

  • Oh, Ju-Taek;Cho, Han-Seon;Lee, Jae-Myung;Shim, Kyu-Don
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.367-374
    • /
    • 2006
  • This research revealed the operation problems of the current crossing control systems through inspecting and testing the obstacle detection systems and gate control systems for the crossings. To resolve the problems of the crossing control systems, this research developed new algorithms of four-quadrant gate system and obstacle detection systems combing the functions of rasar sensors and magnetic sensors and tested the reliability of the systems. Currently, the obstacle detection systems and gate control systems controls approaching and departing traffic by simply detecting vehicles and obstacles but do not consider traffic movements at the crossings. In addition, they do not make signal cooperation for gate controls. As a result, such inefficient crossing controls result in unsafe gate controls for drivers. Therefore, the newly developed crossing control systems through this study will provide more effective crossing control services with more strengthen information cooperation within control systems. Besides they will help to reduce train crashes at the crossings by gate control systems considering various driving behaviors.

Four Quadrant CMOS Current Differentiated Circuit

  • Parnklang, Jirawath;Manasaprom, Ampaul;Ukritnukul, Anek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.948-950
    • /
    • 2003
  • In this literature, the CMOS current mode fout quadrant differentiator circuit is proposed. The implementation is base on an appropriate input stage that converts the input current into a compressed voltage at the input capacitor ($C_{gs}$) of the CMOS driver circuit. This input voltage use as the control output current which flow to the output node by passing through a MOS active load and use it as the feedback voltage to the input node. Simulation results with level 49 CMOS model of MOSIS are given to demonstrate the correct operation of the proposed configuration. But the gain of the circuit is too low so the output differentiate current also low. The proposed differentiator is expected to find several applications in analog signal processing system.

  • PDF

Angle Control for SRCI Fed Induction Motor Drive (SRCI 구동 유도전동기 시스템의 Angle Control)

  • 김인동;조규형
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.12
    • /
    • pp.854-861
    • /
    • 1988
  • The current source inverter-fed induction motor(CSIM) drive is widely used in industry because of its four quadrant operation, fuseless protection, fuseless protection, and ruggedness. the CSIM drive system, however, has shortcomins such as slow response and dynamic stability to load torque disturbance and reference speed change. Such a disadvantages can be compensated considerably by means of introducing additional angle angle control loop. The angle control method is dependent upon the inverter type. In this paper, simultaneus recovery and commutation inverter(SRCI) which is developed recently is considered.

  • PDF

A Study on the Four Quadrant Operation of SRM Drive (SRM의 4상한 구동을 위한 제어방식)

  • Kang Yu-Jung;Park Sung-Jun;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.45-48
    • /
    • 2002
  • Switched Reluctance Generator attracts much attention because of high efficiency, simple controllability with traction drive. But the theories that have been adopted as SRG control methods are complicated up to the present. This paper proposes reference current limitation strategy for stable generation and switching angle control in motoring mode. The proposed method is verified by simulation and experiments.

  • PDF

VARIABLE SPEED CONSTANT FREQUENCY POWER CONVERSION WITH A SWITCHED RELUCTANCE MACHINE

  • Rim, Geun-Hie;Krishnan, R.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1030-1034
    • /
    • 1993
  • A converter topology which is capable of four-quadrant(motoring and generation) operation is proposed for the variable speed constant frequency(hereafter referred as VSCF) power conversion scheme. The new converter topology for the VSCF power conversion scheme is made of two functional stages. One is converting stage which consists of six switches and six diodes and it interfaces a three-phase 60Hz at supply and a single-phase variable-frequency ac source. The other is the commutating stage though which each phase-winding is energized.

  • PDF

Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor (국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작)

  • Jo, Hyunsik;Jo, Jongmin;Oh, Jong-Seok;Suh, Jae-Hak;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.

Transformerless Cascaded AC-DC-AC Converter for Multiphase Propulsion Drive Application

  • Tao, Xing-Hua;Xu, Lie;Song, Yi-Chao;Sun, Min
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.354-359
    • /
    • 2012
  • A transformerless converter suitable for multiphase drive application is presented in this paper. The topology employs a cascaded H-bridge rectifier as the interface between the grid and multi inverters which drive the multiphase motor. Compared with the conventional structure, the new topology eliminates the input transformer and also has the advantages such as four quadrant operation, simple configuration, low cost, high efficiency, and so on. The control strategies for the grid-side cascade H-bridge rectifier and the motor-side inverter are studied accordingly. Based on the multi-rotational reference frame, modular control scheme is developed to regulate the multiphase drive system. Simulation results show the proper operation of the proposed topology and the corresponding control strategy.