• 제목/요약/키워드: Four electrode

검색결과 275건 처리시간 0.023초

Tandem 용접을 이용한 풍력타워 원주용접부 잔류응력 특성에 관한 연구 (A Study on Characteristic of Residual Stresses in a wind Tower Using the Tandem Circumferential Welding Process)

  • 김지선;김인주
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.938-945
    • /
    • 2012
  • This research proposes FEM analysis for Tandem welding process used in wind tower and predicts optimal welding process to improve the stability of welded structures. Three dimensional elasto-plastic analyses are employed to evaluate thermo-mechanical behavior of residual stress and deformation during Tandem welding for different distance between two touches. To confirm the thermal distribution, Goldak's ellipse heat source model and the real size wind tower pipe model are utilized. Four different analyses are being performed, where in each case the distance between two electrode torches is being changed and residual stress and welding deformation are predicted. Depending on base material state, each case is divided into: Liquid (100mm), Austenite+Liquid (200mm), Austenite+Cementite (400mm), Pearlite+Cementite (800mm).

Electrocatalytic Reduction of Dioxygen at Schiff base Co(II) Complexes supported Glassy Carbon Electrode in various pH Solution

  • Park, Kyoung-Hee;Rim, Chae-Pyeong;Chjo, Ki-Hyung;Jeon, Seungwon;Choi, Yong-Kook
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.617-622
    • /
    • 1995
  • Electrocatalytic reduction of dioxygen has been investigated by cyclic voltammetry at glassy carbon electrode modified with new Co(II)-Schiff base complexes in aqueous solutions of various pH. The reduction potentials of dioxygen at chemically adsorbed electrodes show the dependence of pH between pH 4 and 14. The catalytic effect is large and the reaction occurs via two or four electron transfer in various pH solution.

  • PDF

Electrocatalytic Reduction of Molecular Oxygen at Poly(1,8-diaminonaphthalene) and Poly(Co(II)-(1,8-diaminonaphthalene)) Coated Electrodes

  • Park, Hyun;Kwon, Tae-guen;Park, Deog-Su;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1763-1768
    • /
    • 2006
  • The application of poly(Co(II)-(1,8-diaminonaphthalene))(poly(Co-DAN)) and poly(1,8-diaminonaphthalene) (Poly(1,8-DAN)) to the electrocatalytic reduction of molecular oxygen was investigated, which were electrochemically grown by the potential cycling method on the glassy carbon electrodes. The reduction of oxygen at the polymer and its metal complex polymer coated electrodes were irreversible and diffusion controlled. The Poly(1,8-DAN) and Poly(Co-DAN) films revealed the potential shifts for the oxygen reduction to 30 mV and 110 mV, respectively, in an aqueous solution, compared with that of the bare electrode. Hydrodynamic voltammetry with a rotating ring-disk electrode showed that Poly(1,8-DAN) and Poly(Co-DAN) coated electrodes converted respectively 84% and 22% of $O_2$ to $H_2O$ via a four electron reduction pathway.

High-throughput Preparation and Characterization of Powder and Thin-film Library for Electrode Materials

  • Fujimoto, Kenjiro;Onoda, Kazuhiro;Ito, Shigeru
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.254-255
    • /
    • 2006
  • Powder library of pseudo four components Li-Ni-Co-Ti compounds were prepared for exploring the composition region with the single phase of the layer-type structure by using combinatorial high-throuput preparation system "M-ist Combi" based on electrostatic spray deposition method. The new layer-type compounds were found wider composition region than the previous report. This process is promising way to find multi component functional materials.

  • PDF

임피던스 방법에 의한 심장 및 호흡 신호의 측정 (Measurements of Cardiac and Respiratory Signals using Impedance Method)

  • 김형중;심재옥;장재명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.183-186
    • /
    • 1993
  • We have developed a bioimpedance measurement system for impedance cardiography and pneumography. The system injects 50kHz, $200mA_{p-p}$ curreng into the thorax and measures the voltage changes using body surface electrodes. We used the four-electrode method for tile measurement of cardiac singnals and two-electrode method for respiratory signals. We developed a Microsoft Windows program for the acquisition, display, storage, and processing of impedance signals.

  • PDF

XPS Study of MoO3 Interlayer Between Aluminum Electrode and Inkjet-Printed Zinc Tin Oxide for Thin-Film Transistor

  • Choi, Woon-Seop
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권6호
    • /
    • pp.267-270
    • /
    • 2011
  • In the process of inkjet-printed zinc tin oxide thin-film transistor, the effect of metallic interlayer underneath of source and drain electrode was investigated. The reason for the improved electrical properties with thin molybdenum oxide ($MoO_3$) layer was due to the chemically intermixed state of metallic interlayer, aluminum source and drain, and oxide semiconductor together. The atomic configuration of three Mo $3d_3$ and $3d_5$ doublets, three different Al 2p core levels, two Sn $3d_5$, and four different types of oxygen O 1s in the interfaces among those layers was confirmed by X-ray photospectroscopy.

bioimpedance 신호를 이용한 하지동작 분석 (Analysis of leg movements using bioimpedance bignal)

  • 송철규;윤대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.940-942
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot, and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교 (Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units)

  • 신동호;우창규;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

고체전해질 $RbAg_4I_5$ 단결정의 전기전도성과 전극반응 (Electrical Conductance and Electrode Reaction of $RbAg_4I_5$ Single Crystals)

  • 박종희;백운기
    • 대한화학회지
    • /
    • 제24권4호
    • /
    • pp.295-301
    • /
    • 1980
  • 고체전해질 $RbAg_4I_5$의 단결정을 키워서 온도에 따른 전기전도율의 변화를 퍼텐티오메트릭 4-전극방법으로 측정하고 $Ag/RbAg_4I_5$, 계면에 대한 전기화학적 성질을 순환전압전류법으로 조사하였다. 25$^{\circ}C$에서 단결정의 비전기전도율은 $0.284\pm0.003 ohm^{-1}cm^{-1}이었고 \;Ag^+$이온의 이동에 대하여 계산된 활성화에너지는 1.70kcal/mol로서 다결정 시료에 대한 값들과 거의 일치하였다. 순환전압전류법 실험결과 은 기준전극에 대한 전위 0볼트 이하에서는 은 전극에서 $Ag^+$ 이온의 가역적환원이 일어났고 +0.67볼트 이상의 전위에서 요오드화 이온이 산화되어 요오드가 유리되었다. 은의 산화 전위에서 은 전극은 작은 양극전류만을 나타내었으나 환원전위에서 은 전극의 표면에 환원 석출된 은은 다시 양극 전위로 돌아갈 때 아주 큰 산화전류를 나타내었다.

  • PDF

SF6 가스절연에서 부분방전의 특성분석 (Analysis of Partial Discharge Characteristics in SF6 Gas Insulation)

  • 김선재;왕국명;박서준;길경석;안창환
    • 한국전기전자재료학회논문지
    • /
    • 제29권7호
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.