• Title/Summary/Keyword: Four electrode

Search Result 273, Processing Time 0.03 seconds

Comparison of the Earth Resistivity Measured by the 3-Electrode and 4-Electrode Fall-of-Potential Methods (3전극과 4전극 전위강하법으로 측정한 대지저항률의 비교)

  • Lee, Bok-Hee;Kim, Ki-Bok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.95-101
    • /
    • 2013
  • This paper presents the comparison of the earth resistivity obtained from the measurements made with the three-electrode and four-electrode fall-of-potential techniques. The ${\rho}-a$ curve obtained from Wenner four-electrode method in undisturbed earth is in good agreement with the ${\rho}-l$ curve obtained from the three-electrode method based on the fall-of- potential method. However, The ${\rho}-a$ curve in disturbed earth with moisture and freezing is significantly different with the ${\rho}-l$ curve. The ${\rho}-a$ curve is considerably sensitive to the freezing and the moisture present in the earth surface compared to the ${\rho}-l$ curve. Thus to determine the actual earth resistivity, it is necessary to take into account the earth surface conditions when measuring the earth resistivity.

A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode (건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구)

  • Cho, Young Chang;Jeong, Jong Hyeong;Yun, Jeong-oh;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1122-1127
    • /
    • 2019
  • In this study, the bio-impedance of the human body is able to obtain a lot of information by monitoring the pathological and physiological conditions of clinical and biological tissues. The four electrode method system for biometrics measured the potential difference between two electrodes and the other two electrodes were used as electrodes for current flow. The newly developed dry gold electrode measured impedance from 1 Hz to 50 kHz and produced reproducible results. To verify the impedance measurement of the dry electrode, the pitting was performed using an equivalent circuit model of the bioelectrode skin, and the effectiveness was demonstrated through modeling. Fixed electrode types have a constant position of the electrodes attached during the measurement, so that a stable measurement can be obtained, thereby minimizing the error.

The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal (전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구)

  • Lim, Kyeong Min;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

Proposition of the EEG Electrode Arrangement at a Frontal Lobe and Rejection of Noise Using a JADE (전두엽 뇌전도 전극 배치의 제안 및 JADE를 이용한 잡음제거)

  • 박정제;이윤정;김필운;구성모;조진호;김명남
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.227-233
    • /
    • 2004
  • In this paper, it is proposed that the four channel electrode arrangement at a frontal lobe and the noise reduction method using a JADE for the EEG biofeedback system. The proposed electrode arrangement is based on the retina-cornea dipole model. Using JADE and signals which are acquired by the proposed arrangement, four independent components are separated. To estimate a pure EEG component among four components, it is measured that a ratio of alpha wave to the whole signal and then the component that has a maximum value is considered as a pure EEG which the noise is eliminated. As a result of experiments, the proposed methods are effective in reduction of noises during acquisition of the EEG.

Driving Characteristics of the Scanning Mirrors to the Different width and Number of the Grooves on the Electrodes (전극 홈 형상에 따른 스캐닝 미러의 구동 특성)

  • Park, Geun-U;Kim, Yong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.575-580
    • /
    • 2001
  • In this paper, using $500\mum-thickness\; (100)\; silicon\; wafer,\; flat\; 65\mum-thickness$ silicon mirror plates were fabricated through dry etching and wet etching, and $45\mum-depth$ grooved driving electrodes were fabricated through UV-LIGA process. Four shapes of the driving electrode were fabricated: twenty four grooves of the $50\mum-width$, twelve grooves of the $100\mum-width$, six grooves of the $200\mum-width$, and no grooves on the driving electrode. Fabricated mirror plate size and spring size are $2400\times2400\times65\mum3\; and \;500\times10\times65\mum3,$ respectively. Mirror plate parts and driving electrodes were assembled into the scanning mirrors. Measured natural resonance frequencies were about 600Hz which have error within $\pm 2%$ to calculated value. Due to the squeeze effect in the narrow gap between the mirror plate and the driving electrode, measured resonance frequencies were reduced as raising the amplitude of the mirror plate. In a case of driving electrode without grooves, the resonance frequency was reduced largely, compared with a case of driving electrode with grooves. According to the experimental results, squeeze effect was smaller in the driving electrode with smaller-width and many grooves. Therefore, the driving electrode with smaller-width and many grooves was effective in low voltage and high speed operation.

  • PDF

The Flow Characteristics of ER Fluids According to the Electrode Shape of Two Parallel-Plate (평행평판의 전극형상에 따른 ER 유체의 유동특성 I)

  • Jang, S.C.;Yum, M.O.;Kim, D.T.;Kim, T.H.;Bae, T.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.207-212
    • /
    • 2001
  • Electro-Rheological(ER) fluid are suspensions which show an abrupt increase in rheological properties under electric fields. ER effects arise from electrostatic forces between the starch particles dispersed in the electrically insulating silicone oil, induced when an electric field is applied. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields. This paper presents performance analyses of four types of the two parallel-plate. Which have different electrode length and width but same electrode area. On the basis of the pressure drop and flow rate analysis. Four types of the two parallel-plate are designed and manufactured. Using ER fluid, it is possible to directly interface between electric signals and fluid power without moving parts.

  • PDF

Development of New LTPS Process

  • Yi, Chung;Park, Kyung-Min;Choi, Pil-Mo;Kim, Ung-Sik;Kim, Dong-Byum;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1024-1026
    • /
    • 2004
  • We have developed the five mask $PMOS^1$ and the six mask CMOS process architecture for poly-Si TFT. In order to have a competitive process with that for a-Si TFT, the simple co-planar electrode structure whose data line electrode and pixel electrode are on the same plane was adopted. In addition, RGB + White four color $technology^2$ were applied to achieve high aperture ratio and transmittance. Using the aforementioned process architecture and four color technology, 2.0 inch qCIF transmissive micro-reflectance (TMR) device was successfully fabricated.

  • PDF

Electrolytic Conductance Measurement using Four-Electrode Cell and Potentiometric Circuit (포텐티오메트릭 4-전극 용기에 의한 전도도 측정)

  • Jung-Kyoon Chon;Woon-kie Paik
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.2
    • /
    • pp.129-135
    • /
    • 1976
  • A direct-reading conductance measuring system using a potentiostatic circuit and a four-electrode conductance cell was devised. The difficulties with the traditional method of using the Wheatston bridge and a two-electrode cell due to the complicated nature of the electrochemical system, the double layer capacitance and the Faradaic impedance at the electrodes, etc., could be avoided in this method. The devised instrument proved to be convenient and suitable for precise measurements. The results of measured conductivities of KCl and HCl solutions are reported.

  • PDF

SKIN IMPEDANCE MEASUREMENTS USING COMPOUND ELECTRODES (복합형 전극을 이용한 피부의 전기저항 측정)

  • Woo, Eung-Je
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.98-100
    • /
    • 1991
  • We studied the characteristics of the compound electrode and found that the compound electrode provides the four-electrode method in a compact form. We developed a new method of measuring the skin impedance using simple electrodes at low frequencies. At high frequencies where the effect of internal tissue impedance is not negligible, we used the compensation method using compound electrodes since they measure the voltage right under the skin. At 50 kHz, we measured the real part of the skin impedance of less than $80\;{\Omega}$ on the thorax.

  • PDF

A Study of Surface Modification of TiO2 Semiconductor Electrode by Various Overlayers Coating in Dye Sensitized Solar Cells(DSSC) (염료감응형 태양전지에서 $TiO_2$ 반도체전극 표면의 다양한 overlayer 코팅에 따른 특성연구)

  • Kim, Jun-Tak;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.100-100
    • /
    • 2009
  • $TiO_2$ is widely being used as a semiconductor electrode for DSSC. Anti-recombination property and surface area of $TiO_2$ give an important influence to the DSSC efficiency. In this study, $TiO_2$ electrode was fabricated on FTO using screen printing method. Various overlayers were coated on them by dip coating in solution of saturated $Ba(NO_3)_2$, $Mg(NO_3)_2$ and $N_{2}O_{6}Sr$. They reduced the recombination of electrons from photo excited state of Ru dye. The atmospheric plasma treatment was applied to both the $TiO_2$ and each overlayer coated $TiO_2$ surfaces to improve contact ability with dye. We prepared four samples, one sample has bare $TiO_2$ surfaces to improve contact ability with dye. We prepared four samples, one sample has bare $TiO_2$ electrode and the other samples consist of each overlayer coated $TiO_2$ electrodes. We used XRD, FE-SEM, J-V, IPCE and EIS in order to investigate characteristic.

  • PDF