• Title/Summary/Keyword: Four CCD Camera

Search Result 69, Processing Time 0.024 seconds

Comparison of Correction Coefficients for the Non-uniformity of Pixel Response in Satellite Camera Electronics (위성카메라 전자부의 화소간 응답불균일성 보정계수의 비교검토)

  • Kong, Jong-Pil;Lee, Song-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.89-98
    • /
    • 2011
  • Four kinds of gain and offset correction coefficients that are used to correct the nonuniformity between pixels are discussed. And their correction performance has been compared by performing image correction. using the correction coefficients calculated, on the real image data obtained from a newly fabricated camera electronics system. The performance of the correction coefficients depends in general on the number of the light input levels used to obtain the reference image. The result shows that, as expected obviously, when only two light input levles are used to obtain the reference image, even though its correction coefficients are relatively easily calculated, the correction performance is relatively poor. And with the number of light inputs increased to a value of larger than two, the correction performance is improved. It is noted, however, no Significant performance difference is found between the different correction coefficients employed.

Estimation of Total Cloud Amount from Skyviewer Image Data (Skyviewer 영상 자료를 이용한 전운량 산출)

  • Kim, Bu-Yo;Jee, Joon-Bum;Jeong, Myeong-Jae;Zo, Il-Sung;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.36 no.4
    • /
    • pp.330-340
    • /
    • 2015
  • For this study, we developed an algorithm to estimate the total amount of clouds using sky image data from the Skyviewer equipped with CCD camera. Total cloud amount is estimated by removing mask areas of RGB (Red Green Blue) images, classifying images according to frequency distribution of GBR (Green Blue Ratio), and extracting cloud pixels from them by deciding RBR (Red Blue Ratio) threshold. Total cloud amount is also estimated by validity checks after removing sunlight area from those classified cloud pixels. In order to verify the accuracy of the algorithm that estimates total cloud amount, the research analyzed Bias, RMSE, and correlation coefficient compared to records of total cloud amount earned by human observation from the Gangwon Regional Meteorological Administration, which is in the closest vicinity of the observation site. The cases are selected four daily data from 0800 LST to 1700 LST for each season. The results of analysis showed that the Bias in total cloud amount estimated by the Skyviewer was an average of -0.8 tenth, and the RMSE was 1.6 tenths, indicating the difference in total cloud amount within 2 tenths. Also, correlation coefficient was very high, marking an average of over 0.91 in all cases, despite the distance between the two observation sites (about 4 km).

Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals (소동물 발광영상 측정을 위한 광학분자영상기기의 개발)

  • Lee, Byeong-Il;Kim, Hyeon-Sik;Jeong, Hye-Jin;Lee, Hyung-Jae;Moon, Seung-Min;Kwon, Seung-Young;Choi, Eun-Seo;Jeong, Shin-Young;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.344-351
    • /
    • 2009
  • Purpose: Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. Materials and Methods: In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. Results: We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. Conclusion: We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future.

The Design of MSC(Multi-Spectral Camera) Calibration Operation

  • Yong Sang-Soon;Kang Geum-Sil;Jang Young-Jun;Kim Jong-Ah;Kang Song-Doug;Paik Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.601-603
    • /
    • 2004
  • Multi-Spectral Camera(MSC) is a payload on the KOMPSAT -2 satellite to perform the earth remote sensing. The instrument images the earth using a push-broom motion with a swath width of 15 km and a ground sample distance (GSD) of 1 m over the entire field of view (FOV) at altitude 685 Km. The instrument is designed to have an on-orbit operation duty cycle of $20\%$ over the mission lifetime of 3 years with the functions of programmable gain! offset and onboard image data compression/storage. MSC instrument has one(1) channel for panchromatic Imaging and four(4) channel for multi-spectral Imaging covering the spectral range from 450nm to 900nm using TDI CCD Focal Plane Array (FPA). In this paper, the configuration, the interface of MSC hardware and the MSC operation concept are described. And the method of the MSC calibration are described and the design of MSC calibration operation to measure the change of MSC after Launch & Early Operation(LEOP) and normal mission operations are discussed and analyzed.

  • PDF

Motion of Conductive Spherical Particle under Uniform Electric Field (평등전계에서 도전성 구형 입자의 운동)

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

Development of open MMI system for integration of business computers and process computers (포항제철소 B/C-P/C 통합을 위한 개방형 MMI 개발)

  • 추영열;김경백;황화원;김영일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.684-687
    • /
    • 1997
  • In order to access to the Business Computer (B/C), the Process Computer(P/C), and the Database Server in one terminal, the Open Man Machine Interface (MMI) System has been developed. The testbed to develop the interface functions for B/C, P/C, DB server, and CCD camera were constructed, which consisted of Workstations and Personal Computers (PC). Graphic display programs Monitoring the process states of Tandem Cold Mill plant were developed using four Graphic User Interface tools: InTouch, FIX32, Open Interface Environment, and ILOG Views. With regard to the CPU utilization and response delay required to open new display, the performance tests have been carried out on each MMI platform.

  • PDF

A Welding Inspection of Small-sized Metalized Film Capacitor with Large Capacity (소형.대용량 Metalized Film Capacitor의 용접 오차 검출 개발)

  • Jeong, Won-Young;Oh, Choon-Suk;Ryu, Young-Kee;Lim, Jong-Seul;Lee, Seo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.135-137
    • /
    • 2004
  • In this study we'll deal with the small-sized metalized film capacitors with large capacity which head have $5mm{\times}5mm{\times}2.5mm$ dimension. The lead wire is used to weld at both sides of capacitors. At that time the position gap between the welding machine and lead wire supplier would cause the welding error. Also, during the tapping processing of metalized film capacitors, the interval error among the capacitors, the length error of lead frame attached at the capacitors, and the straightness distortion of the lead frame could happen. As mentioned, four kinds of error parameters will be measured and analyzed by using the automatic visual inspection system that is implemented with CCD camera, optical parts, background lighting, and image processing algorithms. Finally we are able to achieve success rate above 99% to detect the welding faults of capacitors in the field test.

  • PDF

Visual servoing of robot manipulators using the neural network with optimal structure (최적화된 신경회로망을 이용한 동적물체의 비주얼 서보잉)

  • 김대준;전효병;심귀보
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.302-305
    • /
    • 1996
  • This paper presents a visual servoing combined by Neural Network with optimal structure and predictive control for robotic manipulators to tracking or grasping of the moving object. Using the four feature image information from CCD camera attached to end-effector of RV-M2 robot manipulator having 5 dof, we want to predict the updated position of the object. The Kalman filter is used to estimate the motion parameters, namely the state vector of the moving object in successive image frames, and using the multi layer feedforward neural network that permits the connection of other layers, evolutionary programming(EP) that search the structure and weight of the neural network, and evolution strategies(ES) which training the weight of neuron, we optimized the net structure of control scheme. The validity and effectiveness of the proposed control scheme and predictive control of moving object will be verified by computer simulation.

  • PDF

Development of an Auto Measuring System for the Earing Rate of Aluminum CAN Using Computer Vision (컴퓨터비젼을 이용한 알루미늄 캔재 이어링률 자동 측정 시스템 개발)

  • 이용중;김형조;이양범
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.288-292
    • /
    • 2003
  • The main purpose of this paper is the development of the system which measures the earing rate of aluminum CAN with the CCD camera. In order to optimize imput image, the image object was segregated and the position of the image grasped. In the pre-processing the edges were detected by the Robert mask after improving the definition of image by the histogram equalization. The height of four each ear and angles which occur due to the characteristics of the aluminum CAN are measured manually with the digital vernier calipers in the industrial ground and in the case of the velocity, these require 30 seconds at least by three times measurement per height of one direction of the aluminum. But it took 0.02 seconds when this system was applied. Therefore this system is proven the satisfactory efficiency and reliability as compared to the control result of in industrial ground.

  • PDF