• Title/Summary/Keyword: Fouling surface

Search Result 278, Processing Time 0.022 seconds

Effect of plasma polymerized film on fouling of heat exchangers

  • Kim, Ki-Hwan;Park, Sung-Chang;doo-Jin choi;Jung, Hyung-Jin;Ha, Sam-Chul;Kim, Chul-Hwan;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.160-160
    • /
    • 1999
  • To reduce the fouling of heat exchangers, the plasma polymerized films was coated on the heat exchangers, and an effect of plasma polymerized film on fouling of heat exchangers was investigated. Monomer and reactive gases were used as the precursors of plasma polymerization. Plasma polymerized films were deposited with process parameters of pressure, power, and ratio of gases. Plasma polymerized films could be served as functional layers of good wettability and high resistance to corrosion. Wettability of plasma polymerized film could be controlled by the ratio change gas mixture. Hydrophilicity of plasma polymerized films on heat exchanger in air conditioner can provide improvement in performance of heat exchanger which results from good water drainage, decrease of pressure drop. DC-plasma polymerized films improve resistance to corrosion whcih is related to deposit formation in heat exchangers. The difference in the build up of fouling deposits between bare substrate and plasma polymerized substrate was investigated by scanning electron microscopy (SEM). An effect of plasma polymerized film on fouling of heat exchangers was discussed in terms of surface properties such as wettability, surface chemical state.

  • PDF

Characterization of a Functional Coating Film Synthesized on the Ceramic Substrate for Electrical Insulator Application according to Coating Method

  • Shan, Bowen;Kang, Hyunil;Choi, Wonseok;Kim, Jung Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.148-150
    • /
    • 2017
  • For the improvement of the anti-fouling features of porcelain electrical insulators, in this study, the surface of an insulator was coated with a functional material to expand the insulator's self-cleanness. The anti-fouling and mechanical features of the functional film coating of ceramic substrates made from components like an electrical insulator were analyzed. The coating methods that were used were spray coating, dip coating, and fabric coating. Following the coating, the contact angle of the coated surface was measured, revealing that the spray coating method offered the lowest angle ($13.7^{\circ}$) and a strong hydrophilic feature. The anti-fouling analysis showed that the anti-fouling features improved as the contact angle decreased. The mechanical properties - hardness and adhesion - were both excellent at 9H and 5B, respectively, regardless of the coating method that was used.

Improvement of Fouling Resistance with Reverse Osmosis Membrane Using Multi-layer Silane-Epoxy Surface Modification (실란-에폭시 다층 표면개질을 통한 역삼투막의 내오염성 향상)

  • Kwon, Sei;Lee, Yong Taek
    • Membrane Journal
    • /
    • v.25 no.4
    • /
    • pp.332-342
    • /
    • 2015
  • In this study, to solve the major problem of reverse osmosis (RO) membrane, surface of reverse osmosis membrane was modified by silane-epoxy multi layer. Octyltrimethoxysilane (OcTES) was polymerized to membrane surface via cross-linking by Sol-gel method. n = 8 alkylgroup of OcTES formed the branch structure by self assembly. And for improve fouling resistance of RO membrane, Ether group of ethylene glycol diglycidyl ether (EGDE) was given to improve hydrophilicity of RO membrane surface by ring-opening. To analyze structure of RO membrane surface with FE-TEM and AFM. Membrane surface of the ridge and valley structure and the bridge structure was confirmed due to the multi-layer surface modification of OcTES and EGDE. And through the increase of the roughness, the branch structure was formed well on membrane surface. Through the XPS analysis was identified chemical structure of membrane surface. And confirmed that the hydrophilic surface modification is given to the surface of the film through a Contact angle analysis. In optimization of EGDE surface modification condition, was suitable 0.5 wt% EGDE concentraion and $70^{\circ}C$ ring-opening temperature. In result of fouling resistance test and MFI is SUL-H10, $PA-OcTES_{1.0}$, $PA-OcTES_{1.0}-EGDE_{0.5}$ 68.7, 60.4, 5.4 ($10E-8hr/mL^2$), multi-layer surface modified membrane improved fouling resistance.

Applicability evaluation of microbubble for membrane fouling reduction in wastewater reuse membrane process (하수재이용 막여과 공정에서 막오염 저감을 위한 마이크로버블 적용성 평가)

  • Lee, Chang-Ha;Kim, Geon-Youb;Kim, Hyung-Soo;Kim, Ji-Hoon;Lee, Kyung-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.169-175
    • /
    • 2017
  • This study applied microbubbles to reduce membrane fouling in wastewater reuse membrane processes, evaluated and compared the transmembrane pressure with or without the application of microbubbles and the cleaning efficiency with the application of aeration and microbubbles. In addition, this study analyzed foulants removed from the membrane surface. Changes in the transmembrane pressure of membranes with the presence or absence of microbubbles were observed. As a result, transmembrane pressure (TMP) increasing rate decreased twofold when applying microbubbles to realize stable operations. This study compared and evaluated cleaning efficiency applying aeration and microbubbles. As a result, the cleaning efficiency was 5% higher on average when applying microbubbles. In turbidity and total organic carbon (TOC), foulants were discharged when applying microbubbles twice as much as applying aeration. It is thought that particulate foulants precipitated on the membrane surface were more likely to desorb because the adhesion between the membrane surface and particle was weakened by microbubbles. Therefore, it is considered possible to effectively control membrane fouling because of the increase in cleaning efficiency when applying microbubbles to wastewater reuse membrane processes.

Anti-fouling Properties of Functional Coating according to the Film Thickness and its Application to the Insulators for Electrical Railway (코팅막의 두께에 따른 기능성 코팅의 내오염 특성 분석 및 전기철도용 애자로의 활용)

  • Shan, Bowen;Kang, Hyunil;Choi, Wonseok;Kim, Jung Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.94-97
    • /
    • 2017
  • A method of improving the anti-fouling characteristics of porcelain insulators was proposed in this study. Functional coating was performed as a method of reducing the surface contamination of the porcelain insulators. The functional coating was applied on a ceramic substrate, which has the same material as the porcelain insulators. After coating the ceramic substrate 2, 3, 4, and 5 times alternately in the horizontal and vertical directions, the surface characteristics according to the thickness of the coating film were analyzed. The optimal process was selected to coat the surfaces of the post insulators and long rod insulators, which are the representative porcelain insulators. After coating, heat treatment was performed for 1 hour at $200^{\circ}C$ in a furnace to secure the durability of the coating film. Compared to the uncoated insulators, the insulators with the functional coating showed significantly improved anti-fouling characteristics as well as excellent adhesion to the coated insulator surface.

A Study on Membrane Fouling Contaminants and Control in Enhanced Sewage Treatment by Submerged Membrane Bioreactor (침지형 분리막을 이용한 오수고도처리 공정의 막오염 원인물질 및 제어에 관한 연구)

  • Park, Chul-Hwi;Yun, Jae-Gon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.619-627
    • /
    • 2004
  • Purposes of this study were to examine closely the extracellular polymeric substances (EPS) which was a membrane fouling contaminant, to control detected EPS by powdered activated carbon (PAC) dosage etc. and to evaluate the possibility of practical reuse facility. With high removal efficiency of general pollutants, when the PAC is added to MBR, improvement of removal efficiency of $COD_{cr}$, and color was expected and treated wastewater can be reused. It was judged that the correlation between EPS and membrane fouling was very high. Carbohydrate and DNA in the EPS were judged to be cause of membrane fouling. If EPS could be controled, not only membrane fouling would be decreased but also operation time would be extended. In experiment of powdered activated carbon (PAC), characteristics of the best PAC for membrane fouling control were the particle size of $7{\mu}m$, lodine Number of 1,050, surface area of peat of $1,150m^2/g$. In lab test, operation time of MBR by PAC dosage of 200mg/gVSS was longer than one of MBR by without PAC dosage. Because EPS, especially carbohydrate and DNA, was controled successfully by PAC, membrane fouling in MBR could be decreased.

Systematic study on calcium-dissolved organic matter interaction in a forward osmosis membrane-filtration system (정삼투 멤브레인 공정에서 칼슘이온과 용존 유기물 상호작용에 의한 플럭스 변화 연구)

  • Heo, Jiyong;Han, Jonghun;Kim, Yejin;Her, Namguk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.737-744
    • /
    • 2016
  • The investigation of effects on fouling propensity with various viscosity of feed solutions would be better understanding for forward osmosis (FO) performance since the fouling propensity was directly influenced with solution viscosity. Therefore, this study was focused on the FO fouling with model foultants (humic acid, alginate) by altering solution viscosity with change of ionic strength (I.S) and $Ca^{2+}$ concentrations. In the comparison between humic acid and alginate, as expected, the alginate generally caused more severe fouling (almost 35.8 % of flux reduction) based on the solution characteristics (high viscosity) and fouling patterns (coil and gel layer). However, interesting point to note is that the fouling propensity of alginate was more severe even though it was applied with low viscosity of feed conditions (I.S = 20 mM, $Ca^{2+}=1mM$). This might be due to that crossed linked gel layer of alginate on the FO membrane surface could be best formed in the condition of $Ca^{2+}$ presence and higher I.S, and that is more dominant to fouling propensity than the low viscosity of feed solutions.

Numerical simulation of resistance performance according to surface roughness in container ships

  • Seok, Jun;Park, Jong-Chun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.11-19
    • /
    • 2020
  • In recent years, oil prices have continued to be low owing to the development of unconventional resources such as shale gas, coalbed methane gas, and tight gas. However, shipping companies are still experiencing difficulties because of recession in the shipping market. Hence, they devote considerable effort toward reducing operating costs. One of the important parameters for reducing operating costs is the frictional resistance of vessels. Generally, a vessel is covered with paint for smoothing its surface. However, frictional resistance increases with time owing to surface roughness, such as that caused by fouling. To prevent this, shipping companies periodically clean or repaint the surfaces of vessels using analyzed operating data. In addition, studies using various methods have been continuously carried out to identify this phenomenon such as fouling for managing ships more efficiently. In this study, numerical simulation was used to analyze the change in the resistance performance of a ship owing to an increase in surface roughness using commercial software, i.e., Star-CCM+, which solves the continuity and Navier eStokes equations for incompressible and viscous flow. The conditions for numerical simulation were verified through comparison with experiments, and these conditions were applied to three ships to evaluate resistance performance according to surface roughness.

Predictions of Fouling Phenomena in the Axial Compressor of Gas Turbine Using an Analytic Method (해석적 방법을 이용한 가스터빈 축류 압축기의 파울링 현상 해석)

  • Song, Tae-Won;Kim, Dong-Seop;Kim, Jae-Hwan;Son, Jeong-Rak;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1721-1729
    • /
    • 2001
  • The performance of gas turbines is decreased as their operating hours increase. Fouling in the axial compressor is one of main reasons for the performance degradation of gas turbine. Airborne particles entering with air at the inlet into compressor adhere to the blade surface and result in the change of the blade shape, which is closely and sensitively related to the compressor performance. It is difficult to exactly analyze the mechanism of the compressor fouling because the growing process of the fouling is very slow and the dimension of the fouled depth on the blade surface is very small compared with blade dimensions. In this study, an improved analytic method to predict the motion of particles in compressor cascades and their deposition onto blade is proposed. Simulations using proposed method and their comparison with field data demonstrate the feasibility of the model. It if found that some important parameters such as chord length, solidity and number of stages, which represent the characteristics of compressor geometry, are closely related to the fouling phenomena. And, the particle sloe and patterns of their distributions are also Important factors to predict the fouling phenomena in the axial compressor of the gas turbine.

Fouling evaluation on nanofiltration for concentrating phenolic and flavonoid compounds in propolis extract

  • Leo, C.P.;Yeo, K.L.;Lease, Y.;Derek, C.J.C.
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.327-339
    • /
    • 2016
  • Nanofiltration is useful to concentrate propolis extract. During the selection of membrane, both compound rejection and permeate flux are important indicators of process economy. Brazilian green propolis extract was studied to evaluate the separation performance of Startmen 122 and NF270 membranes. Compared to Starmen 122, NF270 membrane showed better rejection of bioactive compounds. The flux decline patterns were further studied using Hermia's model. Cake formation is the major fouling mechanism on the hydrophobic surface of Starmen 122. While the fouling mechanism for NF270 is pore blocking. The fouled membranes were further characterized using SEM and FT-IR to confirm on the predicted fouling mechanisms.