• Title/Summary/Keyword: Fouling surface

Search Result 279, Processing Time 0.025 seconds

Effects of membrane orientation on permeate flux performance in a submerged membrane bioreactor

  • Lee, Tsun Ho;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.3 no.3
    • /
    • pp.141-149
    • /
    • 2012
  • The aeration provided in a Submerged Membrane Bioreactor (SMBR) improves membrane filtration by creating turbulence on the membrane surface and reducing membrane resistance. However, conventional hollow fiber membrane modules are generally packed in a vertical orientation which limits membrane scouring efficiency, especially when aeration is provided in the axial direction. In the present research, 3 innovative hollow-fiber membrane modules, each with a different membrane orientation, were developed to improve membrane scouring efficiency and enhance permeate flux. Pilot testing was performed to investigate the permeate flux versus time relationship over a 7-day period under different intermittent modes. The results indicated that the best module experienced an overall permeate flux decline of 3.3% after 7 days; the other two modules declined by 13.3% and 18.3%. The lower percentage of permeate flux decline indicated that permeate productivity could be sustained for a longer period of time. As a result, the operational costs associated with membrane cleaning and membrane replacement could be reduced over the lifespan of the module.

The Safety Survey Analysis and Consideration of Small Transformer (소형 변압기 안전성 실태 분석 및 고찰)

  • Kim, Sung-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

Antifouling effects of the periostracum on algal spore settlement in the mussel Mytilus edulis

  • Kang, Ji-Young;Bangoura, Issa;Cho, Ji-Young;Joo, Jin;Choi, Yoo Seong;Hwang, Dong Soo;Hong, Yong-Ki
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.1
    • /
    • pp.7.1-7.6
    • /
    • 2016
  • In nature, marine mussels (Mytilus edulis) suffer less fouling colonization on the newly formed sides of their shells. Using settlement assays with algal spores of Porphyra suborbiculata, we determined that spore attachment and germination on the periostracum decreased to 36.8 and 3.3 %, respectively. Additionally, the spore settlement was considerably diminished by periostracum dichloromethane extracts containing 19 % oleamide, a major antifouling compound. A scanning electron micrograph of the surface revealed a regular ripple structure with approximately $1.4{\mu}m$ between ripples. Based on these results, mussel periostraca or their associated biomimetic materials may become environmentally friendly, antifouling agents for preventing the settlement of soft foulants.

Current Research Trends in Water Treatment Membranes Based on Nano Materials and Nano Technologies (나노 기술을 이용한 수처리 분리막 소재의 최근 연구동향)

  • Lee, Hee Dae;Cho, Young Hoon;Park, Ho Bum
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.101-111
    • /
    • 2013
  • Nano materials having large surface area, uniform dimensions or pores can be utilized in various membrane applications. Recently, many studies have been focused on the application of nano materials and nano technologies in membrane applications by the help of the discovery and development of nano technologies. in terms of mass transport channels or functional modification. However, there have been several technological limitations for commercialization. Nano materials and nano technologies can improve 1) permeability, selectivity, 2) mechanical, chemical, thermal stability or fouling tolerance of conventional membranes and even 3) introduce new functionalities such as specific affinity and reactivity.

Chemical cleaning of fouled polyethersulphone membranes during ultrafiltration of palm oil mill effluent

  • Said, Muhammad;Mohammad, Abdul Wahab;Nor, Mohd Tusirin Mohd;Abdullah, Siti Rozaimah Sheikh;Hasan, Hassimi Abu
    • Membrane and Water Treatment
    • /
    • v.5 no.3
    • /
    • pp.207-219
    • /
    • 2014
  • Fouling is one of the critical factors associated with the application of membrane technology in treating palm oil mill effluent (POME), due to the presence of high concentration of solid organic matter, oil, and grease. In order to overcome this, chemical cleaning is needed to enhance the effectiveness of membranes for filtration. The potential use of sodium hydroxide (NaOH), sodium chloride (NaCl), hydrochloric acid (HCl), ethylenediaminetetraacetic acid (EDTA), and ultrapure water (UPW) as cleaning agents have been investigated in this study. It was found that sodium hydroxide is the most powerful cleaning agent, the optimum conditions that apply are as follows: 3% for the concentration of NaOH, $45^{\circ}C$ for temperature solution, 5 bar operating pressure, and solution pH 11.64. Overall, flux recovery reached 99.5%. SEM images demonstrated that the membrane surface after cleaning demonstrated similar performance to fresh membranes. This is indicative of the fact that NaOH solution is capable of removing almost all of the foulants from PES membranes.

Ultra- and Nano-Filtration Process Optimization of Isoflavones and Oligosaccharides from Sunmul

  • Kim, Woo-Jung;Kim, Hak-Hyun;Yoo, Sang-Ho
    • Food Science and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.380-386
    • /
    • 2005
  • Optimal conditions of ultrafiltration (UF) and nanofiltration (NF) were investigated for separation and concentration of isoflavones and oligosaccharides from Sunmul. Levels of COD, BOD, and suspended solids (SS) in UF and NF permeates were also determined to evaluate effectiveness of these processes for reducing water pollution. Optimal UF operation conditions to achieve minimal fouling and maximal flux were $33-34^{\circ}C$ operating temperature and 2.3-2.4 bar trans-membrane pressure. Recovery yields of isoflavones and oligosaccharides in UF retentate were 11.49-28.16% and 12.77-27.57%, respectively. Increase in volumetric concentration factor (VCF) resulted in more functional compounds of isoflavones and oligosaccharides passing through UF membrane. Total isoflavone and oligosaccharide yields decreased by 3% as VCF increased from 6.0 to 8.0 and from 8.0 to 10.0, while decreased significantly by 10% as VCF decreased from 4.0 to 6.0. Optimal NF operating conditions were 192-195 psig operating pressure at $30-33^{\circ}C$. Total yields of isoflavones and oligosaccharides significantly decreased at VCF 8.0, whereas did not decrease up to VCF 6.0 during NF operation. Therefore, VCF 6.0 was recommended for economical process. COD and BOD decreased by more than 98% after NF process, and SS were not detected after UF process. These results indicated sequential filtration process was useful for separation of isoflavones and oligosaccharides from Sunmul and for reducing water contaminants.

Determination of electrical and geometric properties of brown eggs

  • Sung Yong Joe;Jun Hwi So;Seon Ho Hwang;Soon Jung Hong;Seung Hyun Lee
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.857-869
    • /
    • 2022
  • Eggs are considered an excellent complete food because they contain many major energy sources, including protein. Eggs are one of the most widely consumed foods worldwide, and egg consumption is steadily increasing. Eggs are generally classified according to their quality and weight. Various characteristics of eggs must be considered for the design and effective utilization of equipment used for the transport, processing, packaging, and storage of eggs. In this study, egg surface area, volume, density, etc. were measured according to the grade of the egg. The values of several geometrical properties that were measured tended to increase with increasing egg grade. The smallest grade eggs had the lowest shell thickness and density. The electrical conductivity of the eggshell and its contents was measured with a self-made electrode and equipment. The egg shell showed properties similar to insulators, and as the thickness increased, the electrical conductivity tended to increase. The electrical conductivity of the egg yolk showed almost constant values under all conditions. The electrical conductivity of the egg white and mixture was particularly low at 0.1 kHz. Fouling and electrode corrosion occurred in a low frequency region due to the egg white. In this study, various geometric and electrical characteristics of eggs were measured, and based on this, factors that could serve as new indicators for egg processed production were analyzed and investigated.

Manufacture and Characteristics of Concrete Sidewalk Blocks Using Photocatalyst Agent (광촉매제를 사용한 콘크리트 보도블록의 제조 및 특성)

  • Jung, Yong-Wook;Chang, Chun-Ho;Kim, Jong-Kyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.423-430
    • /
    • 2019
  • In this study, the flexural strength, absorption rate, methylene blue photo catalyst decomposition performance and anti-fouling performance were evaluated according to the photo catalyst mixing rate and block surface wash status by applying photo catalyst to the surface layer of concrete sidewalk block. The results showed that the flexural strength of the block that mixed photo catalyst only in the surface layer of the concrete block was 5.32MPa of the general block (SNW) of 5% photo catalyst, compared to 5.46MPa of the non-mixed concrete block of the reference concrete block. Surface washing block (SW) 5.26MPa, 10% photo catalyst general block (SNW) 5.26MPa, and 5.15MPa surface washing block (SW). It has been shown that the presence of surface washing and the mixing rate of photo catalyst in the concrete block have no effect on the flexural strength. Moreover, the photoreaction performance of concrete sidewalk blocks showed that the methylene blue removal rate of specimens with 5% TiO2 was 34.2%, the methylene blue removal rate of specimens with 10% TiO2 was 37.1%, and the removal rate of the methylene blue of specimens with 5% TiO2 was about 37.9% and 10% mixed specimens with TiO2 was about 37.6%.

Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water (고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구)

  • Lee, Sanghyup;Yoshimasa, Watanabe;Lee, Seockheun;Ahn, Kyuhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

Low Pressure Hybrid Membrane Processes for Drinking Water Treatment (저압 막여과 혼성공정을 이용한 고도 정수처리)

  • Choo, Kwang-Ho;Chung, Ji-Hyun;Park, Hak-Soon
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.161-173
    • /
    • 2007
  • Membrane filtration processes are increasingly popular for drinking water treatment that requires high quality of water. Low pressure membrane(LPM) processes such as microfiltration(MF) and ultrafiltration(UF), however, are ineffective in the removal of dissolved organic matter and also membrane fouling is still an important issue to be resolved. High pressure membranes(HPMs) may guarantee better water quality, but at the high energy consumption. Thus, various approaches to combine LPM processes with other physicochemical methods have been recently made to achieve their efficiency to the level comparable to that of HPM processes. In this work, therefore, hybrid processes that coupled MF/UF with coagulation, adsorption, chemical reactions(e.g., chelation and oxidation) are reviewed regarding system design and performance and also membrane surface modifications conducted by grafting and polyelectrolyte multilayer formation were assessed.