• 제목/요약/키워드: Forward mode

검색결과 328건 처리시간 0.027초

포워드 컨버터의 노드확장에 의한 전도성 노이즈 감소에 관한 연구 (A Study on Reduction of Conducted-Noise by the Expanded Node of the Forward Converter)

  • 이희훈;권영안
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권7호
    • /
    • pp.374-379
    • /
    • 2006
  • The switch mode power supply is a source of EMI with other equipment as well as with its own proper operation because of rapid changes in voltages and currents within a switching converter. The EMI is transmitted in two forms: radiated and conducted. Conducted noise consists of two categories known as the differential mode and the common mode. Common mode noise current is a major source of EMI in the switch mode Power supply. Recently, a current balancing technique has been studied to reduce the common mode noise. This paper investigates the reduction of common mode noise according to a node expansion of the switch mode power supply which is based on a current balancing technique. In this paper, seven PCB patterns of the forward converter are manufactured and experimented.

GSO 위성으로부터 HAPS 지상국에 미치는 간섭 영향 분석 (The Analysis on the Interference Effects from GSO Satellites into HAPS Ground station)

  • 강영흥;최문환
    • 한국정보통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.523-528
    • /
    • 2004
  • 기존의 고정 위성 서비스(FSS: fixed satellite service)에 할당된 27.5 ∼ 28.35GHz 대역 및 31.0 ∼ 31.3GHz 대역이 WRC-2000에서 성층권 무선 중계 시스템에 할당됨에 따라 FSS/GSO 시스템과 FS/HAPS 시스템간의 간섭 영향 분석이 필요하다. 이러한 간섭 분석에 있어서는 주파수 운용 조건을 크게 Reverse mode와 Forward mode로 구분하여 간섭 분석 모델을 설정해야 한다. 이에 본 논문에서는 FSS/GSO 시스템과 FS/HAPS 시스템간의 간섭 영향을 Forward mode를 고려하여 다수의 GSO 위성들에 의한 HAPS 지상국에 미치는 간섭 영향으로서 I/N 기준 값, HAPS 커버리지 위도, 위성 간격 등에 따른 간섭 평가를 행하였다. 한편, 이러한 간섭의 영향을 줄이기 위해서는 주파수 운용 조건을 Reverse mode로 고려하거나 적절한 간섭 경감 기법을 도입해야 할 것으로 보인다.

HAPS와 FSS간의 주파수 공유를 위한 위성과 HAPS 지상국간의 간섭 분석 (Analysis on the Interference from Satellites to HAPS ground station for Sharing between HAPS and FSS)

  • 최문환;강영흥
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.610-614
    • /
    • 2003
  • WRC-2000에서는 성층권 무선 중계 시스템(HAPS: High Altitude Platform Station)을 위한 주파수 대역으로 27.5 - 28.35GHz 대역 및 31.0 - 31.3GHz 대역을 할당하였다. 그러나, 이 대역은 기존의 고정 위성 서비스(FSS: fixed satellite service)에 이미 할당된 대역이기 때문에 기존의 FSS/GSO 시스템과 FS/HAPS 시스템간의 간섭 영향 분석이 절실히 요구되는 실정이다. 이러한 간섭 분석에 있어서 필요한 주파수 운용 조건은 크게 Reverse mode와 Forward mode로 나누어진다. 본 논문에서는 FSS/GSO 시스템과 FS/HAPS 시스템간의 간섭 영향 분석에 대하여 Forward mode 운용 조건을 고려할 때, 다수의 GSO 위성들로부터 HAPS 지상국으로의 간섭 영향으로서 I/N 기준값, HAPS 커버리지의 위도, 위성 간격 등에 따른 간섭 분석을 행하였다. 이러한 간섭분석 결과는 향후 HAPS와 고정 위성간의 주파수 공유를 위한 기준설정에 활용될 것이다.

  • PDF

A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

Optimal Duplex Selection for Decode and Forward Relay Systems with Power Allocation

  • Kwon, Taehoon;Lim, Sungmook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권12호
    • /
    • pp.5347-5360
    • /
    • 2016
  • In decode and forward relay systems, choosing the duplex mode is an important factor to the performance. To satisfy the performance requirement, self-interference must be mitigated for the full-duplex relay (FDR), and the resource efficiency must be increased for the half-duplex ratio (HDR). Therefore, if a wise scheme to consider these two factors exists, decode and forward relay systems are used more effectively. This study proposes a new duplex selection scheme for decode and forward relay systems. The proposed duplex selection scheme chooses the better duplex mode according to the channel statistical conditions with optimal power allocation. The simulation results show that the proposed duplex scheme with optimal power allocation has lower outage probability than the FDR and the HDR.

PC 전원용 다중출력 포워드 컨버터의 가중치 전압 모드 제어 (Weighted Voltage Mode Control of Multiple Output Forward Converter for PC Power Supply)

  • 차영길
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.501-504
    • /
    • 2000
  • In this paper the PC power supply is studied from the point of system stability. The power stage model of a multiple output forward converter with weighted voltage mode control is derived including all the major parasitic components and the small signal model is also derived. Determination of the weighting factors and a design procedure for the loop compensation are presented. Finally the model is verified through the simulation of three output forward converter with SABER.

  • PDF

CLAMP MODE에서 동작하는 ZVS-MRC FORWARD 콘버어터에 관한 연구 (THE CLAMP MODE FORWARD ZERO-VOLTAGE-SWITCHING MULTI-RESONANT-CONVERTER)

  • 김희준;미스리시문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.210-213
    • /
    • 1991
  • The clamp mode Zero-Volatge-Switched Multi-Resonant-Converter(ZVS-MRC) is proposed. In the converter, the performance of the conventional ZVS-MRC is improved by clamping the drain-to-source voltage of the power switch using a soft switching nondissipative active clamp network. The analysis for each stage of the converter operation modes is presented and is verified by experiments.

  • PDF

가중치 전압 모드 제어를 적용한 PC 전원용 다중출력 포워드 컨버터 (Multiple Output Forward Converter for PC Power Supply with Weighted Voltage Mode Control)

  • 이경주;김성민;이득기;정종진;김흥근
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.307-316
    • /
    • 2001
  • 본 논문에서는 직류 특성과 절전 모드에서 비절전 모드 변환과 같은 부하 변동 시의 동특성을 동시에 개선할 수 있는 가중치 전압 제어를 적용한 PC 전원용 다중출력 포워드 컨버터를 설계하였다. 기생성분을 포함한 전력회로를 모델링하고 소신호 해석하였으며, 가중치 결정 방법과 전압 보상회로 설계 방법을 제시하였다. SABER 시뮬레이션과 실험을 통해 제안한 방법이 PC 전원의 직류 특성과 동특성을 향상시킴을 입증하였다.

  • PDF

AT 포워드 다중공진형 컨버터의 동작 모드 해석 (Mode analysis for the AT Forward MRC)

  • 김상일;김희준;김창선;오원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2691-2694
    • /
    • 1999
  • The multi-resonant converter(MRC) can reduce the switching losses exiting in a converter, so it is capable of operating at a high frequency. Such a few MHz high frequency application provides a high power density [$W/inch^{3}$]. But the high voltage stress across a switch of the resonant circuit is about 4$\sim$5 times the input voltage, it causes increasing of the conduction loss in MRC. In this paper, the mode analysis for the suggested AT Forward MRC with low voltage stress is discussed. The operational modes of the AT Forward MRC are divided to 8 equivalent modes according to the two switching sequences, Each mode is analyzed over all of the paper.

  • PDF

NOISE CHARACTERISTICS OF SIMPLIFIED FORWARD-TYPE RESONANT CONVERTER

  • Higashi, Toru
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.559-562
    • /
    • 2000
  • The problem of noise generation due to PWM switched-mode power converter has been widely noticed from the viewpoint of Electromagnetic Interference(EMI). Many kings of topologies for resonant converters have been developed both to overcome this noise problem and to attain high power efficiency. It is reported in references that resonant converters which are derived from PWM converter using resonant switch show much lower noise characteristics than PWM converter, and that current-mode resonant converter is more sensitive to stored charge in rectifying diode than voltage-mode counterpart concerning surge generation at diode’s turn-off. On the other hand, above mentioned resonant converters have defect of high-voltage stress on semiconductor switch and complicated circuit configuration. Hence, the simplified Forward-type resonant converter has been proposed and investigated due to its prominent features of simplicity of circuit configuration, low voltage stress and high stability. However, its noise characteristics still remain unknown. The purpose of this paper is to study quantitatively the noise characteristics of this simplified Forward-type resonant converter by experiment and analysis. The influence of parasitic elements and stored charge in rectifying diode on noise generation has been clarified.

  • PDF