• Title/Summary/Keyword: Forward head angle

Search Result 184, Processing Time 0.036 seconds

The Effect of the Weight of a Backpack on Craniovertebral Angle and Neck Muscle Activities on Some University Students (백팩 무게가 일부 대학생의 머리척추각과 목 근활성도에 미치는 영향)

  • Park, Cheon-jun;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Background: A backpack is available equipment for moving some objects. Most studies have found that the appropriate weight limit of backpack for students is between 10% to 15% of their body weight (BW). However, Some students should carry a backpack heavier than 15% of BW. Therefore, It is associated with abnormal shoulder and neck posture on students. Objects: This study tested the effects that various amounts of weight carried by university students in their backpacks had on their cervical posture and electromyography of neck muscle. Methods: The subjects consisted of 12 students (6 male, 6 female) in university. There were three loading conditions tested: no backpack, a backpack that weighed 10% and 15% of the student's BW. The dependent variables were the craniovertebral angle (tragus to C7) and the neck muscle activities (sternocleidomastoid, upper trapezius). All 12 subjects were asked to walk while wearing a backpack for 5 minutes and were then instructed to rest for 2 minutes. Results: When assessing the craniovertebral angle, the results of this study were significantly decreased in the order of 0%, 10%, and 15%. And then, there were significantly increased electromyography of neck muscles that comparison of the weight of 10% and 15% on 0%. It was found that as the weight of the backpack increased, the craniovertebral angle decreased (p < 0.05) and the muscle activities increased (upper trapezius p = 0.012, sternocleidomastoid p = 0.013). Conclusion: Our study recommended that some students shouldn't carry on over the 15% backpack of own weight, and also they should distribute backpack load to equal on body for optimal posture.

Research about Intelligent Snake Robot (지능형 뱀 로봇에 관한 연구)

  • Kim, Seong-Joo;Kim, Jong-Soo;Jeon, Hong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.1
    • /
    • pp.70-75
    • /
    • 2003
  • There come various types of robot with researches for mobile robot. This paper introduces the multi-joint snake robot having 16 degree of freedom and composing of eight-axis. The biological snake robot uses the forward movement friction and the proposed artificial snake robot uses the un-powered wheel instead of the body of snake. To determine the enable joint angle of each joint, the controller inputs are considered such as color and distance using PC Camera and ultra-sonic sensor module, respectively. The movement method of snake robot is sequential moving from head to tail through body. The target for movement direction is decided by a certain article be displayed in the PC Camera. In moving toward that target, if there is any obstacle then the snake robot can avoid by itself. In this paper, we show the method of snake robot for tracing the target with experiment.

Research Trends of Posture Pattern in Korea Literature (자세패턴과 관련된 국내 연구동향 분석)

  • Lee, Kang-Joon;Song, Yun-Kyung
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.14 no.1
    • /
    • pp.99-118
    • /
    • 2019
  • Objectives : The purpose of this study was to analyze trends of posture pattern in Korean literature. Methods : We searched four Korean databases (NDSL, RISS, OASIS, and KISTI) and classified the studies according to publication year and the study type. Additionally, we analyzed clinical research papers according to the predominant reported posture pattern, the type of study, assessment for clinical outcomes. Results : In total, 50 published studies were included in our analysis, and we determined the following: By study type, there were 37 interventional studies, 6 observational studies and 7 non-clinical research papers. In the interventional studies, the most common posture pattern was the forward head posture pattern, which was investigated in 22 studies. As a tool for evaluating posture pattern, cervical vertebral angle and the height of the scapula inferior angle are used most. Conclusions : Although this study has provided insight into the commonly investigated posture patterns types in Korean clinical studies, further research is required and future studies should include randomized controlled trials and systematic reviews in their analyses.

Tracing Algorithm for Intelligent Snake-like Robot System

  • Choi, Woo-Kyung;Kim, Seong-Joo;Jeon, Hong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.486-491
    • /
    • 2005
  • There come various types of robot with researches for mobile robot. This paper introduces the multi-joint snake robot having 16 degree of freedom and composing of eight-axis. The biological snake robot uses the forward movement friction and the proposed artificial snake robot uses the un-powered wheel instead of the body of snake. To determine the enable joint angle of each joint, the controller inputs are considered such as color and distance using PC Camera and ultra-sonic sensor module, respectively. The movement method of snake robot is sequential moving from head to tail through body. The target for movement direction is decided by a certain article be displayed in the PC Camera. In moving toward that target, if there is any obstacle then the snake robot can avoid by itself. In this paper, we show the method of snake robot for tracing the target with experiment.

  • PDF

Effects of Starting Angles of a Rearguider on the Performance of a Cross-Flow Fan (리어가이더 시작각 변화가 횡류홴 성능에 미치는 영향)

  • Kim, Hyung-Sub;Kim, Dong-Won;Yoon, Tae-Seok;Park, Sung-Kwan;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1981-1986
    • /
    • 2004
  • A cross-flow fan relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there exists a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, it is difficult to analyze the reciprocal relations of the cross-flow fan because each parameter is independent. Numerical analyses are conducted with different starting angles of the rearguider. Two-dimensional, unsteady governing equations are solved, using FVM, PISO algorithm, sliding grid system and ${\kappa}-{\varepsilon}$ standard turbulence model.

  • PDF

Development of Design Theory on the Tooth Arrangement of the Combine Threshing Drum (콤바인 탈곡치(脫穀齒) 배열(配列)의 설계(設計) 이론(理論))

  • Chung, C.J.;Choi, J.S.;Lee, W.S.;Chung, S.I.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.2
    • /
    • pp.171-176
    • /
    • 1992
  • This study was intended to develop the design theory of the threshing unit of a head-feeding rice combine. It may be applied for various combining capacities with different cutting widths and forward speeds. Design factors in the theoretical development are : (1) dimensions of the threshing drum, (2) tooth approching angle, (3) distance between the adjacent teeth on their spiral setting line, (4) number of spirals, and (5) total number of teeth on the drum. A computer simulation program was developed to predict the proper dimensions for the threshing drum and tooth arrangement. A simulation for the prospective combine with varied capacities was also demonstrated. The parameters analyzed in the developed design theory were shown to be consistent with those of existing combines.

  • PDF

Test-retest Reliability and Concurrent Validity of a Headphone and Necklace Posture Correction System Developed for Office Workers

  • Gyu-hyun Han;Chung-hwi Yi;Seo-hyun Kim;Su-bin Kim;One-bin Lim
    • Physical Therapy Korea
    • /
    • v.30 no.3
    • /
    • pp.174-183
    • /
    • 2023
  • Background: Office workers experience neck or back pain due to poor posture, such as flexed head and forward head posture, during long-term sedentary work. Posture correction is used to reduce pain caused by poor posture and ensures proper alignment of the body. Several assistive devices have been developed to assist in maintaining an ideal posture; however, there are limitations in practical use due to vast size, unproven long-term effects or inconsistency of maintaining posture alignment. We developed a headphone and necklace posture correction system (HANPCS) for posture correction using an inertial measurement unit (IMU) sensor that provides visual or auditory feedback. Objects: To demonstrate the test-retest reliability and concurrent validity of neck and upper trunk flexion measurements using a HANPCS, compared with a three-dimensional motion analysis system (3DMAS). Methods: Twenty-nine participants were included in this study. The HANPCS was applied to each participant. The angle for each action was measured simultaneously using the HANPCS and 3DMAS. The data were analyzed using the intraclass correlation coefficient (ICC) = [3,3] with 95% confidence intervals (CIs). Results: The angular measurements of the HANPCS for neck and upper trunk flexions showed high intra- (ICC = 0.954-0.971) and inter-day (ICC = 0.865-0.937) values, standard error of measurement (SEM) values (1.05°-2.04°), and minimal detectable change (MDC) values (2.92°-5.65°). Also, the angular measurements between the HANPCS and 3DMAS had excellent ICC values (> 0.90) for all sessions, which indicates high concurrent validity. Conclusion: Our study demonstrates that the HANPCS is as accurate in measuring angle as the gold standard, 3DMAS. Therefore, the HANPCS is reliable and valid because of its angular measurement reliability and validity.

Changes of Setup Variables by the Change of Golf Club Length (골프 클럽의 길이 변화에 따른 준비 자세의 변화)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.95-104
    • /
    • 2005
  • To know the proper setup posture for the various clubs, changes of setup variables according to the change of golf club length was investigated. Swing motions of three male low handicappers including a professional were taken using two high-speed videocameras. Four clubs iron 7, iron 5, iron 3 and driver (wood 1) were selected for this experiment. Three dimensional motion analysis techniques were used to get the kinematical variables. Mathcad and Kwon3D motion analysis program were used to analyze the position, distance and angle data in three dimensions. The variables divided into three categories 1) position and width of anterior-posterior direction 2) position and width of lateral direction 3) angles and evaluated based on the theories of many good golf teachers. Major findings of this study were as follows. 1.The stance (distance between ankle joints) was increased as the length of the club increased but the increasing width was not large. It ranges from 5cm to 10cm and professional player showed small changes. 2. Forward lean angle of trunk was decreased (more erected) as the length of the club increased. It ranges from 30 degrees for iron7 to 25 degrees for driver. 3. Angle between horizontal and right shoulder were increased as the length of the club increased. It ranges from 10 degrees to 20 degrees and professional player showed small changes. 4. Anterior-posterior position of the shoulders were located in front of the foot for all clubs and the difference between the shoulder and knee position was decreased as the length of the club increased. 5. Anterior-posterior position of grip (hand) was located almost beneath the shoulders (2.5cm front) for iron7, but it increased to 10cm for the driver. This grip adjustment makes the height of the posture increased only 5cm from iron7 to driver. 6. Lateral position of grip located at 5cm left for the face of iron7, but it located at the right side (behind) for the face of driver. 7. Lateral position of the ball located at the 40%(15cm) of stance from left ankle for iron7 and located at the 10% (5cm) of stance for driver. 8. Head always located at the right side of the stance and the midpoint of the eyes located at the 37% of stance from the right ankle for all clubs. This means that the axis of swing always maintained consistently for all clubs. 9. Left foot opened to the target for all subject and clubs. The maximum open angle was 25 degrees. Overall result shows that the changes of the setup variables vary only small ranges from iron7 to driver. Paradoxically it could be concluded that the failure of swing result from the excessive changes of setup not from the incorrect changes. These findings will be useful for evaluating the setup motion of golf swing and helpful to most golfers.

Impact of Firefighters' Protective Clothing and Equipment on Upper Body Range of Motion (소방용 방화복 및 방화 장비에 따른 상반신 관절 각도의 동작 범위 연구)

  • Kim, Seonyoung;Park, Huiju
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.635-645
    • /
    • 2015
  • This study analyzed the range of motion of upper body in different configurations of firefighters' protective clothing and equipment. The purpose of this study was to understand the influence of firefighters' protective clothing and equipment over upper body motion in order to improve design of firefighters' protective clothing and equipment. 12 firefighters' upper body range of motion was analyzed while performing standing and walking trials in five different garment configurations including turnout ensemble, fire boots and the self-contained breathing apparatus. Analysis of upper body range of motion included spinal joints of L5S1, L4L3, T1C7, and C1Head. During standing trials, garment configurations caused a significant difference in range of motions at joints of L5S1, L4L3, T1C7, and C1Head. Analysis on the mean of range of motions at L5S1 and L4L3, showed that firefighters' waist bent forward significantly to a greater extent while they wore a self-contained breathing apparatus. A significantly increased range of motion was found for T1C7 and C1Head while carrying a self-contained breathing apparatus, which indicated an increase in the extension of the trunk and neck backward to stand upright and look squarely. A significant difference in range of motion was also found for L5S1 and L4L3 during walking trials.

A Case of Multiple System Atrophy with Antecollis and Gait Disturbance Treated with Korean Medicine (경전굴 및 보행장애를 주소로 하는 다계통 위축증 환자의 한의 치료 증례 1례)

  • Kim, Seo-young;Choi, Jeong-woo;Jeong, Hye-seon;Lee, Sang-hwa;Yang, Seung-bo;Cho, Seung-yeon;Park, Jung-mi;Ko, Chang-nam;Park, Seong-uk
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.5
    • /
    • pp.851-864
    • /
    • 2019
  • Multiple system atrophy is a neurodegenerative disease that causes diverse bodily dysfunctions (cerebellar, pyramidal, automatic, and urological, in any combination), as well as Parkinsonism. Patients with multiple system atrophy commonly display antecollis, a condition where the patient's head tilts forward more than 45 degrees. Despite its common occurrence in these patients, no current standardized therapies are effective for treating antecollis. In this study, Korean medicinal treatments, including Chuna manual therapy, pharmaco-acupuncture, bee venom acupuncture, acupuncture, herbal medicine, and moxibustion therapy, were administered to the patient over a 27-day period. After the treatment, assessments of the head position on the EPIS-PD scale (Part I) and at a standing position from the side (Part II) both revealed improvements. As the head flexion angle decreased, the patient's head posture improved, as determined by a decrease in angle from 80 degrees to 30 degrees in the upright, standing position. As a result, patients who previously were unable to walk without the support of walking frames could now roam freely and independently, with significant increases in both walking speed and distance. In essence, this study suggests that Korean medicine is an effective treatment for patients with multiple system atrophy who suffer from antecollis and gait disorders.