• Title/Summary/Keyword: Forward head

Search Result 418, Processing Time 0.022 seconds

Proposal of Modified Velpeau View as an Alternative Test Method of Velpeau View and the Visual Comparison (Velpeau view의 대체 검사법으로서 modified velpeau view의 제안 및 영상 비교평가)

  • Lee, Jae-Hyun;Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.323-328
    • /
    • 2010
  • If a patient wearing arm sliding due to shoulder dislocation or fracture is impossible with abduction, the velpeau view is performed instead of superior-inferior axial projection view. However, it aggravates the patient's pain because it is difficult for the patient with dislocation or fracture to pull back the shoulders. Therefore, I suggest a new method of the 'modified velpeau view' that allows patients to lower their heads at examination. In order to investigate the easiness of fixing posture at examination and clinical utility, I conducted a study comparing the bone structures at the velpeau view and those at the modified velpeau view depending on wall-bucky and the patients' leaning forward angle ($30^{\circ},\;45^{\circ},\;60^{\circ}\;and\;75^{\circ}$), with the subjects of 20 velpeau view-prescribed patients amongst who had come to my hospital suspected of dislocation of shoulder or fracture and 30 healthy people from October of 2009 to January of 2010. Department of radiologists and orthopedics specialists evaluated the pictures for scales 0 to 5(best grade) under the given criteria. As a result of comparison in bone structures depending on wall-bucky and the leaning-forward angle in the group of healthy people, the velpeau view and the modified velpeau showed a similar diagnostic utility at $45^{\circ}$ and $60^{\circ}$. The picture evaluation result for proving diagnostic value showed that the anterior and posterior of shoulder heads and the anterior and posterior of glenoid fossa could be observed in the velpeau view; on the other hand, besides these areas acromioclavicular joint and coracoid process could be viewed in the modified velpeau view. This result verified that the modified velpeau view could replace the velpeau view for its diagnostic value as an examination method. This result, moreover, suggests that the modified velpeau view needs to be studied and improved from a variety of perspectives not only for an alternative for patients having troubles with the velpeau view position but also for clinical application of new test method for diagnosis of shoulder disorders other than dislocation of shoulder or fracture.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

A STUDY ON CEPHALOMETRIC EVALUATION OF MIXED DENTITION CHILDREN WITH NORMAL OCCLUSION (Ricketts 분석법에 의한 혼합치열기 정상교합 아동의 두부방사선계측학적 평가에 대한 연구)

  • Lee, Sang-Min;Jung, Tae-Ryun;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.248-261
    • /
    • 1999
  • In order to define a current set of Korean children norm with mixed dentition, following study was done. The subjects were 102 healthy dentition contestants(48boys, 54girls). Standardized lateral head roentgenograms were taken, and Ricketts analysis was done. Results were as follows: 1. Length of anterior cranial base, posterior facial height, corpus length were longer in male than in female(p<0.05), and Porion was located posteriorly in male than in female(p<0.01). 2. Through facial depth, Pogonion of male was more forwardly positioned(p<0.05), mandible was significantly steeper in female, and maxillary anterior teeth were significantly tipped forward in male(p<0.05). 3. Variables such as length of anterior cranial base, upper molar position(p<0.01) and corpus length(p<0.05) were significantly changed by age. 4. Maxillary height, facial depth, mandibular plane angle, convexity were changed by age, but not significantly(p>0.05).

  • PDF

Spinal Cord Partial Block Technique Using Dynamic MLC (동적 다엽콜리메이터를 이용한 척수의 부분 차폐 기법)

  • 조삼주;이병용;이상욱;안승도;김종훈;권수일;최은경
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2003
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck or the thorax region. It is not an easy task to maintain the spinal cord dose below tolerance and to keep the clinically acceptable dose to the PTV in this region. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. This technique is an extension of the conventional treatment planning. In the beginning the beam directions are selected as same as the conventional treatment planning to encompass the PTV, then the partial block are designed to shield the spinal cord. The plan comparisons between the conventional therapy plan and the PTB plan were performed to evaluate the validity of this technique. The mean dose and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan generated better results than the conventional treatment plan and it was proved to be useful for the H&N region.

  • PDF

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

Comparison on the Kinematic Variables of Racket Movement According to Velocity in Tennis Serve (테니스 서브 속도에 따른 라켓 움직임의 운동학적 변인 비교)

  • Lee, Dong-Jin;Oh, Cheong-Hwan;Jeong, Ik-Su;Park, Chan-Ho;Lee, Gun-Hee
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.337-345
    • /
    • 2009
  • The purpose of this study were to find out the differences in kinematic variables of racket movement by performing the tennis serve. Three top male tennis players participated in this study. Three synchronized high-speed cameras were used to record the service action of top players for Three dimensional video analysis. The results of this study showed that (1) the velocity of the tennis racket at impact is important to the generation of racket velocity to Y-axis. This result indicates that forward motion and upward movement of the racket; (2) with respect to racket angular velocity at impact, the fast angular momentum of X-axis is important to generate the velocity of the tennis ball. This result indicate upward movement of the racket with a strong flexor of wrist joint; (3) the velocity of the tennis ball was influenced by the change of angular linking the Z-axis to -X-axis. This result indicates that the high velocity of the tennis ball is obtained from having the racket unitedly moving to the direction of the bill's flight at the acceleration interval and acquiring the distance of acceleration with the racket head vertically to the ground at the back scratching.

State of Visual Acuity Test and Factors Related to Vision Deterioration of Preschoolers (미취학 아동의 시력검진 실태와 시력저하 관련요인)

  • Lee, Sunghwa;Lee, Haejung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.132-142
    • /
    • 2016
  • The study aimed to examine the state of visual acuity tests in preschoolers and determine the factors affecting the deterioration of their vision. A total of 172 pair, child aged 5-7 years and either one of their parents, were recruited from childcare centers or kindergarten between August 2015 and January 2016. Questionnaires were administered to the parents, and the children's visual acuities were measured. Using forward selection in logistics regression analysis, factors affecting vision deterioration were elucidated. Of 172 children, 128 (74.4%) had undergone a visual acuity test previously and 77 (44.8%) showed a deterioration in their vision. Children who had undergone their first visual acuity test after the age of 7 years (OR=7.425, CI=2.844- 19.385) and showed more abnormal eye symptoms, such as squinting or tilting the head to see or falling down frequently (OR=3.084, CI=1.202-7.914) and whose age was younger (OR=10.335, CI=3.252-32.848), were more likely to develop deterioration of vision. Children who had a posture such that they looked up at the computer monitor from below (OR=.075, CI=.022-.255), were less likely to show deterioration of vision. It can be inferred that early visual acuity tests is essential to detect deteriorated vision of preschoolers. Therefore, it is necessary to educate parents, personnels in day care center, and health clinics about the importance of early visual acuity tests and close observation of specific behaviors related to vision deterioration. Development of precautionary intervention program of vision deterioration in preschoolers and examination of its effects are needed.

Analyses on limitations of binaural sound based on the first order Ambisonics for virtual reality audio (1차 Ambisonics에 의해 생성되는 가상현실 오디오용 양이 사운드의 한계에 대한 분석)

  • Chang, Ji-Ho;Cho, Wan-Ho.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.6
    • /
    • pp.637-650
    • /
    • 2019
  • This paper analyzes the limitations of binaural sound that is reproduced with headphones based on Ambisonics for Virtual Reality (VR) audio. VR audio can be provided with binaural sound that compensates head rotation of a listener. Ambisonics is widely used for recording and reproducing ambient sound fields around a listener in VR audio, and the First order Ambisonics (FOA) is still being used for VR audio because of its simplicity. However, the maximum frequencies with this order is too low to perfectly reproduce ear signals, and thus the binaural reproduction has inherent limitations in terms of spectrum and sound localization. This paper investigates these limitations by comparing the signals arrived at ear positions in the reference field and the reproduced field. An incidence wave is defined as a reference field, and reproduced over virtual loudspeakers. Frequency responses, inter-aural level differences, and inter-aural phase differences are compared. The results show, above the maximum cut off frequency in general, that the reproduced levels decrease, and the horizontal localization can be provided only around the forward direction.

The Effect of Pelvic Tilt on Muscle Activity of Cervical Erector Spinae & Upper Trapezius While Using a Smartphone (골반경사에 따른 스마트폰 사용이 목세움근과 위등세모근의 근활성도에 미치는 영향)

  • Song, Seong-In;Kang, Jong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.97-103
    • /
    • 2017
  • The purpose of this study was to investigate muscle activity of cervical erector spinae & upper trapezius while using a smartphone according to anterior pelvic tilt & posterior pelvic tilt in sitting position. & we also want to obtain basic data necessary for development of IoT devices. Fifteen healthy men & women aged 20-30 were enolled, After anterior pelvic tilt & posterior pelvic tilt in sitting position were adjusted, they used a smartphone for 5 minutes & EMG signal was measured simultaneously. We used median 3 minutes of measured EMG signal. The results of this study were as follows: In the sitting position, the use of smartphone in anterior pelvic tilt had significantly lower %RVC values in both cervical erector spinae (p <.001), left upper trapezius (p <.001) & right upper trapezius (p <.002) in comparison with posterior pelvic tilt. This means that anterior pelvic tilt make vertebrae maintain normal curvature & prevent forward head posture occurred while using a smartphone. It reduces loads around neck & shoulders, so that %RVC value is significantly lowered. In the future, new posture corrected IoT devices with an aspect of pelvic tilt should be developed.